0310115 SCREW,Clamp to boat EVINRUDE
100193A, 100293R, 100882B, 115393M, 115493B, 115593, 115693D, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 200640S, 40072A, 40872A, 40972R, 50172S, 50202C, 50302R, 50442M, 50542B, 55642E, 55872A, 55972A, 60072B, 60172C, 65272S, 6537
SCREW
Price: query
Rating:
Compatible models:
100193A
100293R
100882B
115393M
115493B
115593
115693D
115983E
125183C
125283R
135383M
135443B
135543E
135643D
200640S
40072A
40872A
40972R
50172S
50202C
50302R
50442M
50542B
55642E
55872A
55972A
60072B
60172C
65272S
65372R
70442M
70572B
70673D
75542B
75642D
85093B
85193A
85293R
85393M
85493B
85593E
85693D
85892A
85993E
E150WTLEOR
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- REMOTE CONTRO » 0310115
- REMOTE CONTROL
100882B, 100883B 1968
115393M 1973
115493B 1974
115593 1975
115693D, 115693G, 115699D, 115699G 1976
115983E, 115983S 1969
125183C 1971
125283R 1972
135383M 1973
135443B, 135483B, 135489B 1974
135543E, 135583E, 135589E 1975
135643D, 135643G, 135683D, 135683G 1976
200640S, 200649S 1976
40072A, 40073A 1970
40872A, 40872C, 40872D, 40873A, 40873C, 40873D 1968
40972R, 40973R 1969
50172S, 50173S 1971
50202C, 50203C, 50272C, 50273C 1972
50302R, 50303R, 50372R, 50373R 1973
50442M, 50443M, 50472M, 50473M 1974
50542B, 50543B, 50572B, 50573B 1975
55642E, 55643E, 55672E, 55673E 1976
55872A, 55872R, 55872S, 55873A, 55873R, 55873S 1968
55972A, 55972C, 55973A, 55973C 1969
60072B, 60072D, 60073B, 60073D 1970
60172C, 60172E, 60173C, 60173E 1971
65272S, 65273S 1972
65372R, 65373R 1973
70442M, 70443M, 70472M, 70473M 1974
70572B, 70572E, 70573B, 70573E 1975
70673D 1976
75542B, 75543B 1975
75642D, 75643D 1976
85093B, 85093D 1970
85193A, 85193H 1971
85293R 1972
85393M 1973
85493B 1974
85593E 1975
85693D, 85693G, 85699G 1976
85892A, 85893A 1968
85993E, 85993M, 85993S 1969
E150WTLEOR, E150WTXEOR 1995
Information:
Illustration 1 g01272048
Schematic
Illustration 2 g01113249
P1 ECM connector (P1-43) Engine fan control solenoid (P1-51) Solenoid returnTest Step 1. Inspect Electrical Connectors and Wiring
Remove the electrical power from the ECM.
Thoroughly inspect the ECM connector J1/P1. Inspect all of the other connectors for the circuit. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".
Check the harness and the wiring for abrasion and for pinch points.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Check for Active Diagnostic Codes
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Restore the electrical power to the ECM.
Monitor the active diagnostic code screen on Cat ET. Check and record any active diagnostic codes.Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Determine if the problem is related to an open circuit diagnostic code (05) or a short circuit diagnostic code (06).Expected Result:No diagnostic codes are active.Results:
OK - No diagnostic codes are active.Repair: The problem may have been related to a faulty connection in the harness. Carefully reinspect the connectors and wiring. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - A short circuit diagnostic code (06) is active at this time. Proceed to Test Step 3.
Not OK - An open circuit diagnostic code (05) is active at this time. Proceed to Test Step 4.Test Step 3. Disconnect the Connector for the Fan Control Solenoid in Order to Create an Open Circuit
Remove the electrical power from the ECM.
Disconnect the connector for the fan control solenoid.
Restore the electrical power to the ECM. Wait at least 30 seconds for activation of the diagnostic codes.
Access the "Active Diagnostic Code" screen on Cat ET. Check for an active open circuit diagnostic code (05) for the fan control solenoid.
Remove the electrical power from the ECM.Expected Result:An open circuit diagnostic code (05) is now active for the fan control solenoid.Results:
OK - A short circuit diagnostic code (06) was active before disconnecting the connector. An open circuit diagnostic code (05) became active after disconnecting the connector.Repair: Temporarily connect a new fan control solenoid to the harness, but do not install the new fan control solenoid. Verify that there are no active diagnostic codes for the solenoid. If there are no active diagnostic codes for the solenoid, permanently install the new solenoid. Clear any logged diagnostic codes.STOP
Not OK - There is a short circuit between the solenoid harness connector and the ECM. Leave the solenoid connector disconnected. Proceed to Test Step 5.Test Step 4. Create a Short at the Connector for the Fan Control Solenoid
Remove the electrical power from the ECM.
Install a jumper wire with Deutsch sockets on each end between terminal 1 (fan control solenoid) and terminal 2 (solenoid return) on the solenoid connector. Connect the jumper on the harness side of the connector.
Restore the electrical power to the ECM.
Wait at least 30 seconds for activation of the short circuit diagnostic code (06).Note: Monitor the "Active Diagnostic Codes" screen on Cat ET before installing the jumper wire and after installing the jumper wire.
Remove the jumper wire.
Remove the electrical power from the ECM.Expected Result:A short circuit diagnostic code (06) is active when the jumper wire is installed. An open circuit diagnostic code (05) is active when the jumper wire is removed.Results:
OK - The engine harness and the ECM are OK.Repair: Temporarily connect a new fan control solenoid to the harness, but do not install the new fan control solenoid. Verify that there are no active diagnostic codes for the solenoid. If there are no active diagnostic codes for the solenoid, permanently install the new solenoid. Clear any logged diagnostic codes.STOP
Not OK - The open circuit diagnostic code (05) remains active with the jumper in place. The open circuit is between the ECM and the connector for the fan control solenoid. Proceed to Test Step 5.Test Step 5. Check the Operation of the ECM
Disconnect the J1/P1 ECM connector.
Remove the wire for the fan control solenoid from P1-43. Install a jumper wire with Deutsch sockets on each end into P1-43.
Remove the wire for the fan control solenoid from P1-51. Install a jumper wire with Deutsch sockets on each end into P1-51.
Reconnect the ECM connector.
Restore the electrical power to the ECM. Monitor the "Active Diagnostic Code" screen on Cat ET. Wait at least 30 seconds for activation of the code.An open circuit diagnostic code (05) should be active for the fan control solenoid.
Check the operation of the ECM by creating a short at the ECM.
Install a wire jumper between the jumper wire for the fan control solenoid and the jumper wire for the solenoid return.
Monitor the "Active Diagnostic Code" screen on Cat ET. Wait at least 30 seconds for activation of the code.A short circuit diagnostic code (06) should be active when the wire jumper is installed.
Remove the wire jumpers. Reconnect all wires and connectors.Expected Result:An open circuit diagnostic code (05) is active when the wire from the fan control solenoid is removed f
Parts screw EVINRUDE:
0302812
0302812 SCREW,Cam follower
100193A, 100293R, 100882B, 100990S, 10424G, 10524C, 10624G, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 15404G, 15504C, 15604A, 175740S, 20064
0308186
0308186 SCREW,Rod cap
100193A, 100293R, 100882B, 100990S, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 25702H, 25802C, 25904R, 33002M, 33802M, 3390
0313076
0306461
0306461 SCREW,Coupling
100882B, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25902B, 33002M, 33802M, 33902A, 3802A, 4006E, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 4106D, 4206S, 4902B, 5802B, 65832B, 85852A,
0553556
0553556 SCREW,Thrust plate to gearcase
100193A, 100293R, 100882B, 115083D, 115393M, 115493B, 115593, 115693D, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 18002C, 18102S, 18202R, 18304A, 18902B, 200640S, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 25902B, 652
0310539
0310539 SCREW,Latch
100882B, 100990S, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 50442M, 50542B, 50902C, 55642E, 55772D, 55874S, 70442M, 70572B, 70673D, 70773S, 70873C, 70973R, 75542B, 75642D, 85493B, 85593
0318544
0318544 SCREW, Drain and fill
100990S, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 50302R, 50442M, 65372R, 70442M, 70572B, 70673D, 70773S, 70873C, 70973R, 75542B, 75642D, 85393M, 85493B, 855
0328724
0328724 SCREW, Clamp to anchor block
BE10EEDD, BE10RELEUS, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE130TLECE, BE130TLEDM, BE130TLEUB, BE150ELECD, BE150ELEDB, BE150ELEUC, BE15EEDS, BE15RELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE20SEECB, BE2