0552898 SCREW, Gearcase to exhaust hsg EVINRUDE
100193A, 100293R, 115083D, 115393M, 115493B, 115593, 115693D, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 85093B, 85193A, 85293R, 85393M, 85493B, 85593E, 85693D, 85993E, E40RWCOM
SCREW
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
- GEARCASE » 0552898
115083D 1970
115393M 1973
115493B 1974
115593 1975
115693D, 115693G, 115699D, 115699G 1976
115793S, 115799S, 85793S, 85799S 1977
115983E, 115983S 1969
125183C 1971
125283R 1972
135383M 1973
135443B, 135483B, 135489B 1974
135543E, 135583E, 135589E 1975
135643D, 135643G, 135683D, 135683G 1976
85093B, 85093D 1970
85193A, 85193H 1971
85293R 1972
85393M 1973
85493B 1974
85593E 1975
85693D, 85693G, 85699G 1976
85993E, 85993M, 85993S 1969
E40RWCOM, E40RWLCOM 1985
Information:
Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
E265(3) User Defined Shutdown The inputs from the ground level shutdown switch to the engine's Electronic Control Module (ECM) have changed states. The engine will shut down. The ECM will illuminate the check engine lamp. The ECM will pulse the action lamp and the action alarm at a rate of .5 Hz per second. The action alarm will be activated until the engine is shut down. The code is logged.
267-3 Remote Shutdown Input : Voltage Above Normal Both of the switch contacts of the ground level shutdown switch are in the open state. If both of the switch contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.
The ECM will illuminate the check engine lamp. The ECM will pulse the action lamp and the action alarm at a rate of .5 Hz per second.
267-4 Remote Shutdown Input : Voltage Below Normal Both of the switch contacts of the ground level shutdown switch are in the closed state. The ground level shutdown switch provides the ability to shut down the engine. The engine's ECM remains active. Caterpillar Electronic Technician (ET) can be used to communicate with the ECM. The ground level shutdown switch must be returned to the RUN position and the engine rpm must be zero before the ECM will allow the engine to start.To shut down the engine, lift the red cover guard and toggle the ground level shutdown switch to the SHUTDOWN position. The ECM reads the position of the ground level shutdown switch. If the engine is running, the ECM disables the fuel injection. The status screen will display "INJECTION DISABLED" and "REMOTE SHUTDOWN".The ECM will not allow the engine to start if the status for the ground level shutdown switch is "REMOTE SHUTDOWN".
Illustration 1 g01711594
Schematic
Test Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF position.
Illustration 2 g01141049
J1/P1 ECM connector
Thoroughly inspect the ECM connector J1/P1. Thoroughly inspect the connectors for the ground level shutdown switch. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 3 g01711595
P1 ECM connector
(P1-54) user defined shutdown (NC)
(P1-56) user defined shutdown (NO)
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and the wiring for abrasion and for pinch points. Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The harness and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Status of the Ground Level Shutdown Switch on Cat ET
Connect Cat ET to the service tool connector. Start Cat ET.
Turn the keyswitch to the ON position.
Observe the status of the ground level shutdown switch on Cat ET.
Operate the ground level shutdown switch. Observe the status of the ground level shutdown switch on Cat ET. Expected Result:The status of the ground level shutdown switch on Cat ET is REMOTE SHUTDOWN when the ground level shutdown switch is in the SHUTDOWN position.Results:
OK - The status of the ground level shutdown switch on Cat ET is correct.Repair: The ground level shutdown switch is operating normally. There may be an intermittent problem. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The status of the ground level shutdown switch on Cat ET is incorrect. The ground level shutdown switch is not operating normally. Proceed to Test Step 3.Test Step 3. Create a Short at the Connector for the Ground Level Shutdown Switch
Turn the keyswitch to the OFF position.
Disconnect the connector for the ground level shutdown switch.
Create a short circuit at the connector for the ground level shutdown switch between terminal A and terminal B.
Turn the keyswitch to the ON position.
Observe the status of the ground level shutdown switch on Cat ET.
Create a short circuit at the connector for the ground level shutdown switch between terminal B and terminal C.
Observe the status of the ground level shutdown switch on Cat ET.
Turn the keyswitch to the OFF position.
Remove the wire short. Expected Result:The status of the ground level shutdown switch on Cat ET is REMOTE SHUTDOWN when a short circuit is created at the connector for the ground level shutdown switch between terminal A and terminal B.The status of the ground level shutdown switch on Cat ET is not REMOTE SHUTDOWN when a short circuit is created at the connector for the ground level shutdown switch between terminal A and terminal B.Results:
OK - The status of the ground level shutdown switch on Cat ET is correct.Repair: The problem is not with the harness or the ECM. Temporarily connect a new ground level shutdown switch. Verify that the new ground level shutdown switch solves the problem before you permanently install the new ground level shutdown switch.STOP
Not OK - The status of the ground level shutdown switch on Cat ET is incorrect. There is a problem in the harness and/or the ECM. Proceed to Test Step 4.Test Step 4. Create a Short at the ECM
Fabricate jumper wires that can be used to replace the wires in the ECM connector for the ground level shutdown switch. Crimp a connector socket to one end of the jumper wire.
Disconnect the ECM connector J1/P1.
Remove the wires from ECM connector P1-56 and P1-54.
Install the jumper wires into the terminal locations for the ground level shutdown switch at the ECM connector.
Reconnect the ECM connector J1/P1.
Create a short circuit at the P1 ECM connector between the jumper wire in P1-56 and
Parts screw EVINRUDE:
0308777
0308777 SCREW,Cover
100193A, 100293R, 100882B, 10424G, 10524C, 10624G, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 15404G, 15504C, 15604A, 175740S, 200640S, 25904R, 33002M
0303587
0303587 SCREW,Cover plate LONG SHAFT MODELS
100193A, 100293R, 100882B, 115083D, 115393M, 115493B, 115593, 115693D, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 18002C, 18102S, 18202R, 18304A, 18802A, 18902B, 25002C, 25102S, 25202R, 25302A, 25402M, 25502B, 25602E, 257
0307922
0307922 SCREW
100193A, 100293R, 115083D, 115983E, 125183C, 125283R, 33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40202E, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R, 55872A, 55972A, 60072B, 60172C, 85093B, 85193A, 85293R, 85993E
0312811
0312811 SCREW, Breaker base
100193A, 200640S, 55872A, 55972A, 60072B, 60172C, 65272S, 65372R, 65832B, 70442M, 70572B, 70673D, 70773S, 75542B, 75642D, 85093B, 85193A, 85293R, 85852A, 85892A, 85993E
0551706
0551706 SCREW, Retainer
100193A, 100293R, 10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 115083D, 115393M, 115983E, 15404G, 15504C, 15604A, 50172S, 50202C, 50302R, 50442M, 55872A, 55972A, 60072B, 60172C, 65272S, 85093B, 85193A, 85293R, 85393M, 85993E, E10ECSE, E10ELCID, E1
0313075
0313075 SCREW, Valve to shaft
100193A, 100293R, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 175740S, 200640S, 65832B, 85093B, 85193A, 85293R, 85393M, 85493B, 85593E, 85693D, 85852A, 85892A, 85993E
0315003
0315003 SCREW, Terminal block
100193A, 100293R, 10424G, 10524C, 10624G, 10724A, 10824M, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 150840S, 15404G, 15504C, 15604A, 175740S, 200640S, 25702H, 25802C,
0314733