0314880 EVINRUDE SEAL,Impeller housing plate


0314880 SEAL,Impeller housing plate EVINRUDE 115693D, 115793S, 135643D, 85693D SEAL
0314880 SEAL,Impeller housing plate EVINRUDE
Rating:
63

Buy SEAL,Impeller housing plate 0314880 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 102
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

115693D, 115693G, 115699D, 115699G 1976
115793S, 115799S, 85793S, 85799S 1977
135643D, 135643G, 135683D, 135683G 1976
85693D, 85693G, 85699G 1976

Information:


Illustration 1 g00835551
Typical schematicTest Step 1. Check for an Open Circuit in the OFF/RESET position.
If equipped, disconnect the remote start/stop initiate contacts from the terminal strip in the Generator Terminal box.
Disconnect the harness connector from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Turn the ECS to the OFF/RESET position.
At the GSC+ harness connector, measure the resistance from contact "39" to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "39" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - All resistance measurements are correct. Proceed to test step 2.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after troubleshooting is complete.STOPTest Step 2. Check for an Open Circuit in the AUTO position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the AUTO position. Measure the resistance from contact "40" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "33" and "39" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "40" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "33" and "39" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 3.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 3. Check for an Open Circuit in the MAN/START position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.
Check whether the corresponding contact of the GSC+ harness connector is the only contact that is connected to the battery negative.
Place the ECS in the MAN/START position. Measure the resistance from contact "33" of the GSC+ harness connector to the − Battery terminal of the relay module. Measure the resistance from contacts "32", "39" and "40" to the − Battery terminal. Make a note of the resistances that are measured.Expected Result:The resistance that is measured from contact "33" to the − Battery terminal of the relay module should be 5 Ohms or less. The resistance that is measured from contacts "32", "39" and "40" to the − Battery terminal should be greater than 5000 Ohms.Results:
OK - The resistance measurements are correct. Proceed to test step 4.
Not OK - The resistance measurements are NOT correct. The harness wiring with the incorrect resistance measurement is open or the harness wiring has failed. Repair: Repair the harness wiring or replace the harness wiring. Repair the wiring or replace the wiring between the − Battery terminal, the ECS, and the GSC+. Reconnect the remote start/stop initiate contacts after the troubleshooting is completed.STOPTest Step 4. Check for an Open Circuit in the COOLDOWN/STOP position.
If equipped, the remote start/stop initiate contacts will remain disconnected from the terminal strip in the Generator Terminal box.
The harness connector remains disconnected from the GSC+.


Parts seal EVINRUDE:

0315403
SEAL, Valve housing
0315403 SEAL, Valve housing
100193A, 100293R, 115083D, 115393M, 115493B, 115593, 115793S, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 85093B, 85193A, 85293R, 85393M, 85493B, 85593E, 85993E
0318451
 
0318451 SEAL, Upper
115393M, 115493B, 115593, 115693D, 135383M, 135443B, 135543E, 135643D, 200640S, 85393M, 85493B, 85593E, 85693D
0319250
 
0319250 SEAL RING, Two stripes
100990S, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 85493B, 85593E, 85693D, E100MLCSC, E100WMLCOC, E100WMLCRS, E115MLCIH, E115MLCNB, E115MLCSA, E115MLCTE, E140MLCIH, E140MLCNB,
0319244
SEAL RING,One stripe
0319244 SEAL RING,One stripe
100990S, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 85493B, 85593E, 85693D, BE115ELEDR, BE115ELEUA, BE115GLECM, BE115TLEDA, BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175
0319197
 
0319197 SEAL RING,Three stripes
100990S, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, 85493B, 85593E, 85693D, E100MLCSC, E100WMLCOC, E100WMLCRS, E115MLCIH, E115MLCNB, E115MLCSA, E115MLCTE, E140MLCIH, E140MLCNB,
0207251
 
0207251 SEAL, Motor cover
115790S, 135443B, 135543E, 135643D, E115MLCNB, E140MLCNB, E90MLCNB
0321668
SEAL
0321668 SEAL
100990S, 115693D, 115790S, 115793S, 115890C, 135643D, 150840S, 150940C, 175740S, 200640S, 40604A, 50902C, 55642E, 55772D, 55874S, 70673D, 70773S, 70873C, 70973R, 75642D, 85693D, E100MLCSC, E100WMLCOC, E100WMLCRS, E110MLCDC, E115MLCIH, E115MLCNB, E115
0322575
 
0322575 SEAL,Upper
100990S, 115790S, 115793S, 115890C, 150840S, 150940C, 175740S, C155WTLM, CE275TLCDC, CE275TLCOS, CE300TLCDC, CE300TLCOS, E100MLCSC, E100STLCCA, E100STLCEM, E100STLEIE, E100STLEND, E100STLESB, E100WMLCDR, E100WMLCOC, E100WMLCRS, E100WTLCUA, E100WTLEIB
Back to top