5006059 Service manual - English EVINRUDE
E200DCXSOC, E200DHLSOC, E200DHLSOG, E200DPLSOC, E225DCXSOC, E225DHLSOC, E225DHLSOF, E225DHLSOG, E225DPLSOC, E225DPZSOC, E250DCXSOC, E250DPLSOC
Service
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
This part in 2 request:
Show.
This information for suppliers only!
#82501 5006059
2021-05-25
#71636 5006059
2020-04-22
Compatible models:
BRP EVINRUDE entire parts catalog list:
- LITERATUR » 5006059
E200DHLSOG 2004,2005
E200DPLSOC, E200DPXSOC, E200DSLSOC 2004,2005
E225DCXSOC, E225DCZSOC 2004,2005
E225DHLSOC, E225DHXSOC 2004,2005
E225DHLSOF 2004,2005
E225DHLSOG, E225DHXSOG 2004,2005
E225DPLSOC, E225DPXSOC 2004,2005
E225DPZSOC 2004,2005
E250DCXSOC, E250DCZSOC 2004,2005
E250DPLSOC, E250DPXSOC, E250DPZSOC 2004,2005
Information:
Table 1
Diagnostic Trouble Codes
J1939 Code CDL Code Code Description Comments
168-2 168-2 Battery Potential / Power Input #1 : Erratic, Intermittent, or Incorrect This code indicates that the battery circuit to the ECM is intermittent.
168-3 168-3 Battery Potential / Power Input #1 : Voltage Above Normal The ECM detects voltage that is above the acceptable value.
168-4 168-4 Battery Potential / Power Input 1 : Voltage Below Normal The ECM detects voltage that is below the acceptable value.
Follow the troubleshooting procedure to identify the root cause of the fault.
Illustration 1 g06409461
Typical example of the schematic for the electrical power supply circuit
Illustration 2 g06409491
View of the pin locations on the P1 connector for the ignition keyswitch and battery supply circuit
(5) Ignition keyswitch
(6) Ignition keyswitch
(12) Battery -
(13) Battery +
(26) Main power relay
(27) Main power relay
(36) Battery -
(37) Battery +
(60) Battery -
(61) Battery +
(62) Battery -
(70) Battery +
Table 2
Troubleshooting Test Steps Value Results
1. Determine the Diagnostic Code
A. Establish communication between the electronic service tool and the ECM . Refer to Troubleshooting, "Electronic Service Tools", if necessary.
B. Start the engine. Run the engine until the engine is at normal operating temperature.
C. Observe the "Active Diagnostic" screen on the electronic service tool. Wait at least 30 seconds so that any codes may become active.
Diagnostic code
Result: One of the diagnostic codes listed in Table 1 is active.
Proceed to Test Step 2.
Result: The electronic service tool will not communicate with the ECM.
Repair: Refer to Troubleshooting, "Electronic Service Tool Does Not Communicate".
2. Check the Charging Circuit
A. Check the charging circuit. Refer to Systems Operation, Testing and Adjusting, "Charging System - Test".
Charging circuit
Result: The charging system is OK.
Proceed to Test Step 3.
Result: The charging system is not OK.
Repair: There is a fault in the charging system. Make the necessary repairs.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
3. Load Test the Batteries
A. Use a suitable battery load tester to test the batteries. Refer to Systems Operation, Testing and Adjusting, "Battery - Test" for the correct procedure.
Load test
Result: The batteries pass the load test.
Proceed to Test Step 4.
Result: The batteries do not pass the load test.
Repair: Recharge or replace the faulty batteries.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
4. Inspect Electrical Connectors and Wiring
A. Ensure that the battery disconnect switch is in the CLOSED position.
B. Thoroughly inspect all connectors associated with the electrical power supplies.
C. Check all fuses.
D. Perform a 45 N (10 lb) pull test on each of the wires in the connectors associated with the electrical power supplies.
E. Check all the wiring associated with the electrical power supplies for abrasions and pinch points.
F. Verify that the "System Operating Voltage Configuration" is correctly configured in the Engine ECM configuration parameters.
Damaged wire or connector. Blown fuse.
Result: A damaged wire or damaged connector was found. A blown fuse was found.
Repair: Repair the damaged wire or the damaged connector. Replace all blown fuses.
Use the electronic service tool to clear all logged diagnostic codes. Verify that the repair eliminates the fault.
Result: The "System Operating Voltage Configuration" is configured incorrectly.
Repair: Program the parameter with the correct system voltage.
Result: A damaged wire or damaged connector was not found. The fuses are OK.
Contact the Dealer Solutions Network (DSN).