0584128 EVINRUDE SOLENOID ASSY.


0584128 SOLENOID ASSY. EVINRUDE E10EEIR, E10EENA, E10EESC, E15EEIA, E15EENM, E15EESR SOLENOID
0584128 SOLENOID ASSY. EVINRUDE
Rating:
33

Buy SOLENOID ASSY. 0584128 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$31.21
 

18-06-2021
5.6[2.25] Pounds
-: -
Johnson/Evinrude/OMC New OEM SOLENOID AY,START 0584128, 584128
SKU: 0584128 || Sold Each || Please verify your own fitment
$18.63
 

20-07-2022
0.25[0.00] Pounds
-: -
Peach Motor Parts PM-0584128 Solenoid, Starter; Replaces Johnson Evinrude OMC: 0584128, 584128, 0778025, 778025, 0981410, 981410, 0982187, 982187, 0985063, 985063, Arco: SW268, Sierra: 18-58 Made b
New
Number on catalog scheme: 22
 

Compatible models:

BRP EVINRUDE entire parts catalog list:

E10EEIR, E10ELEIR, E10REIR, E10RELEIR, E10RLEIR, E10SELEIR, TE10RELEIR 1991
E10EENA, E10ELENA, E10RELENA, E10RENA, E10RLENA, E10SELENA, TE10RELENA 1992
E10EESC, E10ELESC, E10RELESC, E10RESC, E10RLESC, E10SELESC, TE10ELESC, TE10RELESC, TE10RLESC 1990
E15EEIA, E15ELEIA, E15REIA, E15RELEIA, E15RLEIA 1991
E15EENM, E15ELENM, E15RELENM, E15RENM, E15RLENM 1992
E15EESR, E15ELESR, E15RELESR, E15RESR, E15RLESR 1990

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
4376-5
Aftertreatment #1 DEF Return Valve : Current Below Normal 3862-5
Aftertreatment #1 DEF Return Valve Solenoid : Current Below Normal This code indicates that there is problem with the Diesel Exhaust Fluid (DEF) pump reverting valve or the Pump Electronic Tank Unit (PETU) wiring harness.
4376-6
Aftertreatment #1 DEF Return Valve : Current Above Normal 3862-6
Aftertreatment #1 DEF Return Valve Solenoid : Current Above Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
4376-14
Aftertreatment #1 DEF Return Valve : Special Instruction 3862-14
Aftertreatment #1 DEF Return Valve Solenoid : Special Instruction This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
4442-5
Aftertreatment #2 DEF Dosing Unit #1 Diverter Valve : Current Below Normal 5009-5
Aftertreatment #2 DEF Return Valve #1 Solenoid : Current Below Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
4442-6
Aftertreatment #2 DEF Dosing Unit #1 Diverter Valve : Current Above Normal 5009-6
Aftertreatment #2 DEF Return Valve #1 Solenoid : Current Above Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
4442-14
Aftertreatment #2 DEF Dosing Unit #1 Diverter Valve : Special Instruction 5009-14
Aftertreatment #2 DEF Return Valve #1 Solenoid : Special Instruction This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7536-5
Aftertreatment #1 DEF Dosing Unit #2 Diverter Valve : Current Below Normal 5008-5
Aftertreatment #1 DEF Return Valve #2 Solenoid : Current Below Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7536-6
Aftertreatment #1 DEF Dosing Unit #2 Diverter Valve : Current Above Normal 5008-6
Aftertreatment #1 DEF Return Valve #2 Solenoid : Current Above Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7536-14
Aftertreatment #1 DEF Dosing Unit #2 Diverter Valve : Special Instruction 5008-14
Aftertreatment #1 DEF Return Valve #2 Solenoid : Special Instruction This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7537-5
Aftertreatment #2 DEF Dosing Unit #2 Diverter Valve : Current Below Normal 5010-5
Aftertreatment #2 DEF Return Valve #2 Solenoid : Current Below Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7537-6
Aftertreatment #2 DEF Dosing Unit #2 Diverter Valve : Current Above Normal 5010-6
Aftertreatment #2 DEF Return Valve #2 Solenoid : Current Above Normal This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
7537-14
Aftertreatment #2 DEF Dosing Unit #2 Diverter Valve : Special Instruction 5010-14
Aftertreatment #2 DEF Return Valve #2 Solenoid : Special Instruction This code indicates that there is problem with the DEF pump reverting valve or the PETU wiring harness.
Table 2
Required Tools
Part Number Part Name Qty
372-5260 Test Kit 1
Illustration 1 g06100969
Illustration 2 g06522418
(1) Aftertreatment #1 DCU #1 (blue)
(2) Aftertreatment #1 DCU #2 (green)
(3) Aftertreatment #2 .DCU #1 (yellow)
(4) Aftertreatment #2 .DCU #2 (red)
(5) Aftertreatment #1 DEF pump #1 (blue)
(6) Aftertreatment #1 DEF pump #2 (green)
(7) Aftertreatment #2 DEF pump #1 (yellow)
(8) Aftertreatment #2 DEF pump #2 (red)
Table 3
Troubleshooting Test Steps Values Results
1. Check the Pump Electronic Tank Unit (PETU) Wiring Harness for the Reverting Valve for an Open Circuit
A. Turn the keyswitch to OFF for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the Diesel Exhaust Fluid Control Unit (DCU).
B. Disconnect the PETU wiring harness from the affected DEF pump and the affected DCU.
C. Connect the 398-5063 Probe to the DCU wiring harness connector.
D. Connect the 398-5056 Probe to the DEF pump wiring harness connector.
The probe must be used to prevent damage to the DCU and DEF pump wiring harness connectors.
E. Measure the resistance between the following terminals on the affected DEF pump connector and the affected 86-pin DCU wiring harness connector.
- Terminal 11 (reverting valve +) on the DEF pump wiring harness connector and Terminal 86 (reverting valve +) on the 86-pin DCU wiring harness connector.
- Terminal 12 (reverting valve -) on the DEF pump wiring harness connector and Terminal 65 (reverting valve -) on the 86-pin DCU wiring harness connector.
10 Ohms
Result: There were less than 10 Ohms of resistance on both of the reverting valve wires.
Proceed to Test Step 2.
Result: There were more than 10 Ohms of resistance on either wire for the reverting valve.
Repair: There is an open in the harness. Repair the wiring or replace the harness.
Verify that the repair eliminated the problem.
Proceed to Test Step 4.
2. Check the PETU Wiring Harness for the Reverting Valve for a Short Circuit
A. Turn the keyswitch to OFF.
B. Disconnect the PETU wiring harness from the affected DEF pump.
C. Disconnect


Parts solenoid EVINRUDE:

0397909
SOLENOID ASSY., Primer
0397909 SOLENOID ASSY., Primer
C155WTLM, E100STLCCA, E100STLCEM, E100STLESB, E100WTLCUA, E100WTLESM, E100WTLZ, E10EESC, E110MLCCA, E110MLCEM, E110MLCUR, E115MLESB, E120TLCCA, E120TLCEM, E120TLCUR, E120TLESB, E125ESXESS, E125ESXW, E140CXCCS, E140CXCEC, E140CXESR, E140TLCUA, E150CXC
0434326
SOLENOID ASSY., Primer
0434326 SOLENOID ASSY., Primer
E100STLEIE, E100WTLEIB, E10EEIR, E115JLEIE, E120TLEIE, E140CXEIA, E150CXEIE, E150STLEIE, E155WTLEIB, E15EEIA, E175STLEID, E200CXEIB, E20EEIE, E225CXEIC, E250CXEIE, E25EEID, E28ESLEIB, E28ESLEIB, E300CXEIE, E30EEIC, E40EEIA, E45RCEIA, E48ESLEIM, E48ES
0434762
SOLENOID ASSY., Primer
0434762 SOLENOID ASSY., Primer
E100STLEND, E100STLERC, E100STLETS, E100WTLENE, E100WTLERS, E100WTLETD, E10EENA, E112TSLERS, E115JKLERS, E115JLEND, E115JLERC, E115JLETS, E120TLEND, E125ESXENR, E140CXENM, E155WTLENE, E15EENM, E185ESXENR, E200CXENE, E20EEND, E20EERC, E20EETS, E225CXE