0391617 EVINRUDE STARTER PULLEY AND PIN


0391617 STARTER PULLEY AND PIN EVINRUDE E25CNE, E25ECIB, E25ECRS, E25ECTD, E25RSA, E25RSLS, E25RWCRD, E30ECRR, E35ECIG, E35ECND, E35ECRR, E35ECTS STARTER
0391617 STARTER PULLEY AND PIN EVINRUDE
Rating:
38

Buy STARTER PULLEY AND PIN 0391617 EVINRUDE genuine, new aftermarket parts with delivery
Number on catalog scheme: 5
 

BRP EVINRUDE entire parts catalog list:

E25CNE, E25ELCNE, E25RCNB, E25RLCNB, E25TECNB, E25TELCNB 1982
E25ECIB, E25ECIM, E25ELCIB, E25ELCIM, E25RCIM, E25RLCIM, E25TECIM, E25TELCIM 1981
E25ECRS, E25ELCRS, E25RCRD, E25RLCRD, E25TECRD, E25TELCRD 1984
E25ECTD, E25ELCTD, E25RCTE, E25RLCTE, E25TECTE, E25TELCTE 1983
E25RSA, E25RSLA, E25RWCIM, E25RWLCIM 1981
E25RSLS, E25RSS, E25RWCTE, E25RWLCTE 1983
E25RWCRD, E25RWLCRD 1984
E30ECRR, E30ELCRR 1984
E35ECIG, E35ELCG, E35ELCIG, E35RCIG, E35RLCIG 1981
E35ECND, E35ELCND, E35RCND, E35RLCND, E35TELCNB 1982
E35ECRR, E35ELCRR, E35RCRR, E35RLCRR, E35TELCRR 1984
E35ECTS, E35ELCTS, E35RCTS, E35RLCTS, E35TELCTS 1983

Information:


Illustration 1 g03681285
Schematic diagram for the ECM switched battery supply
(1) Fuse for the ECM switched battery circuit
Illustration 2 g03681293
View of the pin locations on the P1 connector
(19) Switched battery +
(24) Engine glow plug relay
(53) Fuel lift pump relay
(54) ARD air pump relay
(74) ARD glow plug relay
Table 2
Troubleshooting Test Steps Values Results
1. Check for Active or Recently Logged Diagnostic Codes
A. Connect the electronic service tool to the diagnostic connector.
B. Turn the keyswitch to the ON position. Do not start the engine.
C. Check for active or recently logged diagnostic codes.
Diagnostic codes
Result: A 4016-6 diagnostic code is active or recently logged.
Proceed to Test Step 2.
Result: A 4016-6 diagnostic code is not active or recently logged. The fault may be intermittent.
Refer to Troubleshooting, "Electrical Connectors - Inspect" in order to identify intermittent faults.
2. Inspect Electrical Connectors and Wiring
A. Turn the keyswitch to the OFF position
B. Check the fuses.
C. Check the harness for abrasion and pinch points from the relays back to the ECM and from the ECM back to the battery.
D. Thoroughly inspect the ECM ground strap.
E. Thoroughly inspect the relays and the connector for the relays.
F. Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are shown in Illustration 1.
Loose connector or damaged wire
Result: There is a fault with the harness and connectors. A fuse is blown.
Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all of the seals are correctly in place and ensure that the connectors are correctly connected. Replace any blown fuses.
If fuse (1) is replaced and the fault reoccurs, continue with this procedure.
Result: All connectors, pins, and sockets are correctly coupled and/or inserted. The harness and connectors are free of corrosion, abrasion, and pinch points. The fuses are OK.
Proceed to Test Step 3.
3. Check the Ground Wiring Between the Battery and the ECM
A. Turn the keyswitch to the OFF position.
B. Disconnect the wire from the battery negative terminal. Disconnect the wire from the battery positive terminal.
C. Disconnect the P1 connector from the ECM.
D. Use a suitable multimeter to measure the resistance between the wire that was removed from the battery negative terminal and the following terminals:
P1:20
P1:39
P1:40
P1:59
P1:60
P1:79
P1:80
Less than 5 Ohms
Result: At least one of the resistance measurements is greater than 5 Ohms. The fault is in the wiring between the battery negative terminal and the P1 connector.
Replace the faulty wiring.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All of the resistance measurements are less than 5 Ohms
Proceed to Test Step 4.
4. Check the Application Wiring for a Short Circuit
A. Use the electronic service tool to clear all logged diagnostic codes.
B. Turn the keyswitch to the OFF position.
C. Disconnect all of the relays that are shown in Illustration 1.
Note: Do not disconnect any other relays other than the relays that are shown in Illustration 1.
D. If fuse (1) has blown, then replace the fuse.
E. Turn the keyswitch to the ON position.
F. Use the electronic service tool to check for an active or recently logged 4016-6 diagnostic code.
G. Turn the keyswitch to the OFF position.
H. Check fuse (1).
Diagnostic code or blown fuse
Result: The fuse is blown and/or a 4016-6 diagnostic code was active or recently logged.
Replace the application wiring. Reconnect the relays.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: The fuse is OK. A 4016-6 is not active or recently logged.
Leave the relays disconnected. Proceed to Test Step 5.
5. Check the Relays
A. Turn the keyswitch to the OFF position.
B. Reconnect one of the relays that was disconnected in the previous Test Step.
C. Turn the keyswitch to the ON position.
D. Use the correct override in the electronic service tool to activate the relay that was reconnected.
ARD Glow Plug Relay "ARD #1 Glow Plug Relay"
Engine Glow Plug Relay "Glowplug Switch Output Override"
ARD Air Pump Relay "ARD Air System Relay Override"
Fuel Lift Pump Relay "Engine Fuel Supply Lift Pump Relay Override"
E. Use the electronic service tool to check for an active or recently logged 4016-6 diagnostic code.
F. Turn the keyswitch to the OFF position.
G. Check fuse (1).
Diagnostic code or blown fuse
Result: Either a 4016-6 diagnostic code became active or the fuse was blown. The fault is in the relay that was reconnected.
Install a replacement relay.
Reconnect all relays. Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: A 4016-6 diagnostic code is not active. The fuse is not blown.
Repeat this Test Step for each relay. Replace any relay that indicates a fault.
Use the electronic service tool to clear all logged diagnostic codes and verify that the repair eliminates the fault.
Result: All relays are connected. A 4016-6 diagnostic code is not active. The fuse is not blown. There may be an intermittent fault.
Refer to Troubleshooting, " Electrical Connectors - Inspect" in order to identify intermittent faults.