0394163 STERN BRACKET ASSY., Stbd. EVINRUDE
E4RDHCCS, E4RDHCDE, E4RDHCEC, E4RDHCUD, E4RDHESR, E6RCCS, E6RCDE, E6RCEC, E6RCOB, E6RCRM, E6RCUD, E8RCCS, E8RCDE, E8RCEC, E8RCOB, E8RCRM, E8RCUD
STERN
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
$21.97
19-08-2022
0.1[0.05] Pounds
-: -
For Hyundai Santa Fe 2010 2011 2012 Engine Water Pump Housing Gasket
Part: Engine Water Pump Gasket || Part Number: 039-4163 || Matches OE form, fit and function || Metal where applicable || Quality construction for durability
Part: Engine Water Pump Gasket || Part Number: 039-4163 || Matches OE form, fit and function || Metal where applicable || Quality construction for durability
$21.97
19-08-2022
0.1[0.05] Pounds
-: -
For Kia Sorento 2011 12 13 14 2015 Engine Water Pump Housing Gasket
Part: Engine Water Pump Gasket || Part Number: 039-4163 || Matches OE form, fit and function || Metal where applicable || Quality construction for durability
Part: Engine Water Pump Gasket || Part Number: 039-4163 || Matches OE form, fit and function || Metal where applicable || Quality construction for durability
Compatible models:
BRP EVINRUDE entire parts catalog list:
- MIDSECTION » 0394163
E4RDHCEC, E4RDHLCEC 1989
E4RDHCUD, E4RDHLCUD 1987
E4RDHESR, E4RDHLESR 1990
E6RCCS, E6RLCCS, E6SLCCS 1988
E6RCDE, E6RLCDE, E6SLCDE 1986
E6RCEC, E6RLCEC, E6SLCEC 1989
E6RCOB, E6RLCOB, E6SLCOB 1985
E6RCRM, E6RLCRM, E6SLCRM 1984
E6RCUD, E6RLCUD, E6SLCUD 1987
E8RCCS, E8RLCCS, E8SRLCCS 1988
E8RCDE, E8RLCDE, E8SRLCDE 1986
E8RCEC, E8RLCEC, E8SRLCEC, TE8RCEC, TE8RLCEC 1989
E8RCOB, E8RLCOB, E8SRLCOB 1985
E8RCRM, E8RLCRM, E8SRLCRM 1984
E8RCUD, E8RLCUD, E8SRLCUD 1987
Information:
Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
336-2 Engine Control Switch erratic, intermittent, or incorrect The inputs from the start/run/stop switch are in a different state. The code is logged. The Electronic Control Module (ECM) receives two input signals from the start/run/stop switch. The two input signals should have the same logic level. If two different signals are detected during the powerup, the ECM will determine that one of the signals is incorrect. The duplication of the signals permits the ECM to know if there is a problem in the wiring.When both of the input signals are high or open, the ECM assumes that the start/run/stop switch is in the STOP position. When both of the input signals are low or shorted to the digital return terminal, the ECM assumes that the start/run/stop switch is in the START position. After the start/run/stop switch is turned to the START position, the ECM will initiate the starting sequence. The ECM will energize the prelube system if the prelube system is available and activated. After the prelube cycle is completed the ECM will energize the start enable relay. If both of the signals go high or open while the engine is running, the engine will stop.If the engine is running and one of the inputs from the start/run/stop switch changes states, the ECM will ignore the inputs from the start/run/stop switch until power is cycled to the ECM. If this occurs, you must use the emergency stop switch or you must disconnect the power to the ECM in order to shut down the engine.If the inputs from the start/run/stop switch are in opposite states at the beginning of a crank cycle, the ECM will not initiate the crank cycle. A diagnostic code will be logged and a diagnostic code will be active for this problem. The diagnostic code for this problem will be active until the ECM is powered down.
Illustration 1 g01934723
Typical schematic
Illustration 2 g01259533
P1 ECM connector
(P1-21) Start/Run/Stop switch 3
(P1-22) Start/Run/Stop switch 4
Illustration 3 g01973157
P2 ECM connector
(P2-6) Digital return
Illustration 4 g01234146
Location of ECM connectors
Illustration 5 g01259500
Connector "A"
(Terminal 25) Digital return
Illustration 6 g01259501
Connector "B"
(Terminal 2) Start/Run/Stop switch 3
(Terminal 3) Start/Run/Stop switch 4
Illustration 7 g01259503
Connector "G"
(Terminal 4) Start/Run/Stop switch 4
(Terminal 6) Start/Run/Stop switch 3
(Terminal 37) Digital return Test Step 1. Inspect Electrical Connectors and Wiring
Turn the breaker for the ECM to the OFF position.
Thoroughly inspect the ECM connectors. Inspect all of the other connectors for the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector that are associated with the circuit.
Check the ECM connector (allen head screw) for the proper torque. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Check the harness and the wiring for abrasion and for pinch points. Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted. The harness and wiring are free of corrosion, of abrasion, and of pinch points.Results:
OK - The connectors and wiring are OK. Proceed to Test Step 2.
Not OK - There is a problem in the connectors and/or wiring.Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Status of the Start/Run/Stop Switch on Caterpillar Electronic Technician (ET)
Turn the breaker for the ECM to the ON position.
Connect Cat ET to the service tool connector.
Turn the start/run/stop switch to the STOP position.
Monitor the status for the start/run/stop switch on Cat ET.
Turn the start/run/stop switch to the START position.
Monitor the status for the start/run/stop switch on Cat ET.
Turn the start/run/stop switch to the STOP position. Expected Result:The status for the switch reads "OFF" when the start/run/stop switch is turned to the STOP position. The status for the switch reads "ON" when the start/run/stop switch is turned to the START position.Results:
OK - The status for the switch is correct in both the STOP and START positions.Repair: The switch is functioning correctly. Reset the system and check for any active diagnostic codes. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - The parameter for the switch is not correct in either the STOP position or in the START position. Proceed to Test Step 3.Test Step 3. Check the Wiring for an Open Circuit
Turn the breaker for the ECM to the OFF position.
Disconnect the ECM connector J1/P1.
Note the location of the wires on the start/run/stop switch. Remove the wires from the start/run/stop switch.
Install a wire jumper between the wire 998-BR(Brown) and the wires F716-WH(White) and F717-YL(Yellow) at the start/run/stop switch.
Measure the resistance between P1-21 and P1-5 at ECM connector P1.
Measure the resistance between P1-22 and P1-5 at ECM connector P1.
Remove the wire jumper.
Parts stern EVINRUDE:
0394162
0394162 STERN BRKT. ASSY., Port (includes item 16)