0304709 STOP, Leaf EVINRUDE
33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R, E40RSLR, E40RWCDB, E40RWCOM, E40RWCRA
STOP
Price: query
Rating:
Compatible models:
BRP EVINRUDE entire parts catalog list:
33802M, 33802R, 33803M, 33803R, 33852M, 33852R, 33853M, 33853R 1968
33902A, 33903A, 33952A, 33953A 1969
40002A, 40003A 1970
40052A, 40053A 1970
40072A, 40073A 1970
40102B, 40102G, 40103B, 40103G, 40152B, 40152G, 40153B, 40153G 1971
40202E, 40203E, 40252E, 40253E 1972
40304D, 40305D, 40354D, 40355D 1973
40404S, 40405S, 40454S, 40455S 1974
40504C, 40505C, 40554C, 40555C 1975
40604A, 40604R, 40605A, 40605R, 40654A, 40654R, 40655A, 40655R 1976
40802A, 40802D, 40802S, 40803A, 40803D, 40803S 1968
40852A, 40852C, 40852D, 40852S, 40853A, 40853C, 40853D, 40853S 1968
40872A, 40872C, 40872D, 40873A, 40873C, 40873D 1968
40902R, 40903R 1969
40952R, 40953R 1969
40972R, 40973R 1969
E40RSLR, E40RSR, E40RWLCTR, E40RWLTR 1983
E40RWCDB, E40RWLCDB 1986
E40RWCOM, E40RWLCOM 1985
E40RWCRA, E40RWLCRA 1984
Information:
Recommended Actions
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Diagnostic Codes
Use one of the following methods to check for active diagnostic codes:
Flash Codes
The display on the control panel
The electronic service toolFlash CodesNote: The following procedure is only applicable if the machine is equipped with the appropriate warning lamps.
Check the warning lamps on the control panel for flash codes. Flash codes are explained in Troubleshooting, "Flash Codes".
If any flash codes are displayed, troubleshoot the codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Display on the Control PanelNote: The following procedure is only applicable if the application is equipped with a display on the control panel.
Check the display on the control panel for active diagnostic codes.
Troubleshoot any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Electronic Service Tool
Connect the electronic service tool to the diagnostic connector.
Check for active diagnostic codes on the electronic service tool.
Investigate any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Visible Faults
Visually inspect the engine for the following faults:
Missing components
Damaged components
Damaged electrical cables or loose electrical cables
Oil leaks
Fuel leaks
Check the following items:
Check for smoke from the exhaust when the engine is cranking. If smoke is seen during cranking, there may be a mechanical fault in the engine. Refer to "Low Compression (Cylinder Pressure)".
Check for the proper level of fuel, oil, and coolant.
Ensure that the fuel supply valve (if equipped) is in the full OPEN position.
If the ambient temperature is below 0 °C (32 °F), ensure the correct specification of engine oil and oil for the machine is used.
Check that the battery voltage is correct.
Use the electronic service tool to check the average cranking speed of the engine. If the cranking speed
Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again.
Diagnostic Codes
Use one of the following methods to check for active diagnostic codes:
Flash Codes
The display on the control panel
The electronic service toolFlash CodesNote: The following procedure is only applicable if the machine is equipped with the appropriate warning lamps.
Check the warning lamps on the control panel for flash codes. Flash codes are explained in Troubleshooting, "Flash Codes".
If any flash codes are displayed, troubleshoot the codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Display on the Control PanelNote: The following procedure is only applicable if the application is equipped with a display on the control panel.
Check the display on the control panel for active diagnostic codes.
Troubleshoot any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Electronic Service Tool
Connect the electronic service tool to the diagnostic connector.
Check for active diagnostic codes on the electronic service tool.
Investigate any active codes before continuing with this procedure. Refer to Troubleshooting, "Troubleshooting with a Diagnostic Code".
Attempt to start the engine. If the engine will not start, proceed to "Visible Faults".Visible Faults
Visually inspect the engine for the following faults:
Missing components
Damaged components
Damaged electrical cables or loose electrical cables
Oil leaks
Fuel leaks
Check the following items:
Check for smoke from the exhaust when the engine is cranking. If smoke is seen during cranking, there may be a mechanical fault in the engine. Refer to "Low Compression (Cylinder Pressure)".
Check for the proper level of fuel, oil, and coolant.
Ensure that the fuel supply valve (if equipped) is in the full OPEN position.
If the ambient temperature is below 0 °C (32 °F), ensure the correct specification of engine oil and oil for the machine is used.
Check that the battery voltage is correct.
Use the electronic service tool to check the average cranking speed of the engine. If the cranking speed
Parts stop EVINRUDE:
0310802
0310802 STOP, Shifter lock
33002M, 33802M, 33902A, 40002A, 40052A, 40072A, 40102B, 40202E, 40304D, 40802A, 40852A, 40872A, 40902R, 40952R, 40972R
0311864
0311864 .STOP, Pinion
25202R, 25302A, 25402M, 25502B, 25602E, 33002M, 33802M, 33902A, 40052A, 40072A, 40102B, 40202E, 40304D, 40404S, 40504C, 40604A, 40852A, 40872A, 40952R, 40972R
0305379