0327196 EVINRUDE SUPPORT,Front stbd.


0327196 SUPPORT,Front stbd. EVINRUDE E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECOB, E40ECRM, E40ECUD, E40WREES, E40WRLSIR, E40WRLSSC, E45RCCDS, E45RCCUC, E45RCE, E45RCEIA, E45RCENM, E45RCEOD, E45RCERE, E45RCESR, E45RCETB, E45RCLEDS, E45RCLEUC, E48ESLCCC, E48ESLCCC, E48ESLCUS, E48ESL SUPPORT
0327196 SUPPORT,Front stbd. EVINRUDE
Rating:
8

Buy SUPPORT,Front stbd. 0327196 EVINRUDE genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$61.95
 

10-04-2024
5.6[2.52] pounds
US: LEADERS RPM
327196 Evinrude/Johnson/OMC Front STBD Lower Engine Cowl Support
Johnson Evinrude OMC SKU: 0327196 || Sold Each || Please verify your own fitment
Number on catalog scheme: 14
 

BRP EVINRUDE entire parts catalog list:

E35AELCDE, E35ARLCDE 1986
E35AELCUD, E35ARLCUD 1987
E40AELCCS, E40ARLCCS, E40ATLCCS, E40ECCS, E40ELCCS, E40RCCS, E40RLCCS, E40TECCS, E40TELCCS, E40TLCCS, E40TTLCCS 1988
E40ECDE, E40ELCDE, E40RCDE, E40RLCDE, E40TECDE, E40TELCDE, E40TLCDE 1986
E40ECOB, E40ELCOB, E40RCOB, E40RLCOB, E40TECOB, E40TELCOB 1985
E40ECRM, E40ELCRM, E40RCRM, E40RLCRM, E40TECRM, E40TELCRM 1984
E40ECUD, E40ELCUD, E40RCUD, E40RLCUD, E40TECUD, E40TLCUD 1987
E40WREES, E40WRLEES, E40WRYEES 1999
E40WRLSIR, E40WRSIR, E40WRYSIR 2001
E40WRLSSC, E40WRSSC, E40WRYSSC 2000
E45RCCDS, E45RCLCDS 1986
E45RCCUC, E45RCLCUC 1987
E45RCE, E45RCLE, E45WMLE 1989
E45RCEIA, E45RCLEIA, E45WMLEIA 1991
E45RCENM, E45RCLENM, E45WMLENM 1992
E45RCEOD, E45RCLEOD 1995
E45RCERE, E45RCLERE 1994
E45RCESR, E45RCLESR, E45WMLESR 1990
E45RCETB, E45RCLETB 1993
E45RCLEDS, HE45RCLEDS, SE45RSLH 1996
E45RCLEUC, HE45RCLEUC, SE45RSLB 1997
E48ESLCCC 1988
E48ESLCCC, VE48ESLCCC 1988
E48ESLCUS 1987
E48ESLCUS 1987
E50BECCS, E50BELCCS, E50TELCCS, E50TLCCS 1988
E50BECDE, E50BELCDE, E50TELCDE, E50TLCDE 1986
E50BECIC, E50BELCIC 1981
E50BECNR, E50BELCNR 1982
E50BECOB, E50BELCOB, E50TELCOB, E50TLCOB 1985
E50BECRM, E50BELCRM, E50TELCRM, E50TLCRM 1984
E50BECTA, E50BELCTA, E50TELCTA 1983
E50BECUD, E50BELCUD, E50TELCUD, E50TLCUD 1987
E50ECSR, E50ELCSR 1980
E55RCIM, E55TLCIM 1981
E55RLCSA 1980
E55RSLC, HE55RSLC, SE55RSC, SE55RSLC, SE55RSYC 1997
E55RSLG 1995
E55RSLN, E55RSLN-2, E55RSN, E55RSN-2, E55RSYN, E55RSYN-2 1983
E55RSLW, HE55RSLW, SE55RSLW, SE55RSW, SE55RSYW 1996
E55RWLCDC 1986
E55RWLCOS 1985
E55RWLCRD 1984
E55RWLCUC 1987
E55RWLE 1989
E55RWLEIA 1991
E55RWLENM 1992
E55RWLERE 1994
E55RWLESR 1990
E55RWLETB 1993
E55WREES, E55WRLEES, E55WRYEES 1999
E55WRLSIR, E55WRSIR, E55WRYSIR 2001
E55WRLSSC, E55WRSSC, E55WRYSSC 2000
E60ECIA, E60ECIH, E60ELCIA, E60ELCIH, E60TLCIA, E60TLCIH 1981
E60ECNM, E60ELCNM, E60TLCNM 1982
E60ECSR, E60ELCSR 1980
E60ECTB, E60ELCTB, E60TLCTB 1983
E60ELCOD, E60TLCOD 1985
E60ELCRE, E60TLCRE 1984
HE55WMLM 1996
HE55WMLZ 1997
M55RWLR 1988
R45RCLR, R45RCR 1988
SE40RPB, SE40RPLB, SE40RPYB 1997
SE40RPH, SE40RPLH, SE40RPYH 1996
SE40RPLT2, SE40RPT2, SE40RPYT2 1998
SE55RSLM2, SE55RSM2, SE55RSYM2 1998

Information:


Table 1
Diagnostic Codes Table
Description Conditions which Generate this Code System Response
E085(1) Engine Shutdown Overridden Warning The engine's Electronic Control Module (ECM) detects ground on the input for the protection override switch. If an engine derate or an engine shutdown is active, the derate or the shutdown will be overridden.
The code is logged.
E097(1) Engine Derate Overridden Warning System OperationIf full engine power is needed, the protection override switch allows the user to override an engine derate or an engine shutdown. The wires for the protection override switch are routed from the ECM to the remote junction box. The wires are then routed to a customer supplied switch.
Illustration 1 g01259011
Typical schematic
Illustration 2 g01259014
P1 ECM connector
(P1-64) Protection override switch
Illustration 3 g01234146
Location of ECM connectors
Illustration 4 g01259018
Connector "B"
(Terminal 21) Protection override switch
Illustration 5 g01259019
Connector "G"
(Terminal 26) Protection override switch
(Terminal 28) −Battery
Illustration 6 g01259021
Connector "F"
(Terminal 2) −Battery Test Step 1. CHECK FOR AN "ACTIVE" EVENT CODE
Turn the breaker for the ECM to the ON position.
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. Proceed to Test Step 2.
Not OK - An event code is not active.Repair: If the problem is intermittent, refer to Troubleshooting, "Inspecting Electrical Connectors" for the correct procedures for inspecting electrical connectors.STOPTest Step 2. CHECK THE POSITION OF THE PROTECTION OVERRIDE SWITCH
Visually check the position of the protection override switch. Expected Result:The protection override switch is in the ON position.Results:
OK - The protection override switch is in the ON position.Repair: Determine the reason that the protection override switch is in the ON position.STOP
Not OK - The protection override switch is in the OFF position. Proceed to Test Step 3.Test Step 3. CHECK THE SIGNAL WIRE BETWEEN THE PROTECTION OVERRIDE SWITCH AND THE ECM
Disconnect the wire N917-RD(Red) from the protection override switch.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between the protection override switch and the ECM. Proceed to Test Step 4.
Not OK - An event code is not active.Repair: The short circuit is most likely in the protection override switch. Replace the switch.STOPTest Step 4. CHECK THE SIGNAL WIRE BETWEEN CONNECTOR "G" AND THE ECM
Disconnect the wire N917-RD(Red) from terminal 26 of connector "G".
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between the connector "G" and the ECM. Proceed to Test Step 5.
Not OK - An event code is not active.Repair: The short circuit is between the protection override switch and connector "G". Replace the wire or repair the wire.STOPTest Step 5. CHECK THE SIGNAL WIRE BETWEEN CONNECTOR "B" AND THE ECM
Disconnect the wire N917-RD(Red) from terminal 21 of connector "B".
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the wire between connector "B" and the ECM. Proceed to Test Step 6.
Not OK - An event code is not active.Repair: The short circuit is between connector "G" and connector "B". Replace the wire or repair the wire.STOPTest Step 6. CHECK THE SIGNAL AT THE ECM
Disconnect the wire N917-RD(Red) from the P1-64 ECM connector.
Monitor the event codes on Cat ET. Check and record any event codes. Note: Wait at least 30 seconds in order for the event codes to become active.
Determine if the problem is active and related to the following event codes:
E085
E097Expected Result:An E085 event code or an E097 event code is active.Results:
OK - An E085 event code or an E097 event code is active. The short circuit is in the ECM.Repair: Replace the ECM. Refer to the diagnostic procedure Troubleshooting, "Replacing


Parts support EVINRUDE:

0312191
 
0312191 SUPPORT,Indicator
100193A, 100293R, 100882B, 100990S, 10424G, 10524C, 10624G, 10724A, 10824M, 10924B, 115083D, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 115983E, 125183C, 125283R, 135383M, 135443B, 135543E, 135643D, 15404G, 15504C, 15604A, 18002C,
0316002
 
0316002 SUPPORT, Front port
50172S, 50202C, 50302R, 50442M, 50542B, 55642E, 55772D, 55874S, E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECOB, E40ECRM, E40ECUD, E40WREES, E40WRLSIR, E40WRLSSC, E45RCCDS, E45RCCUC, E45RCE, E45RCEIA, E45RCENM, E45RCEOD, E45RCERE, E45RCESR, E45RCET
0122730
 
0122730 SUPPORT BRACKET
115693D, 115793S, 135643D, 85693D, E35AELCDE, E35AELCUD, E40AELCCS, E40ECDE, E40ECUD, E45RCE, E50BECCS, E50BECDE, E50BECIC, E50BECNR, E50BECOB, E50BECRM, E50BECTA, E50BECUD, E55RCIM, E55RWLE, E60ECIA, E60ECNM, E60ECTB, E60ELCOD, E60ELCRE
0323398
 
0323398 SUPPORT, Plate
4806E, 4904D, 50902C, 55874S, 6804B, 6904E, E35AELCDE, E40ECDE, E40ECOB, E40ECRM, E4RLCSS, E50BECDE, E50BECIC, E50BECNR, E50BECOB, E50BECRM, E50BECTA, E50ECSR, E55RCIM, E55RLCSA, E55RSLN, E55RWLCOS, E55RWLCRD, E5RCIC, E5RCSS, E5RHCNR, E5RHCTA, E60ECI
0332063
 
0332063 SUPPORT, Plate
BE40EECR, BE40EEDS, BE40EEUC, BE4RDHEDS, BE50BEEDS, BE50ESECC, BE50RLEUC, BE5DREDS, BE5DREUC, BE6DRECR, BE6DREDS, BE6DREUC, BE8RCB, BE8RCH, BE8RCLT, BE8REDS, E35AELCUD, E40AELCCS, E40ECEC, E40ECUD, E40EEIA, E40EENJ, E40EEOD, E40EERE, E40EESR, E40EETB
0124645
 
0124645 SUPPORT, Shift & throttle
E28ELCDS, E28ELCDS, E28ESLCCR, E28ESLCCR, E28ESLCUC, E28ESLCUC, E48ESLCUS, E48ESLCUS, E88MSLCUS, E88MSLCUS
0341171
 
0341171 SUPPORT, Starter pulley
BE40EECR, BE40EEDS, BE40EEUC, BE50BEEDS, BE50ESECC, BE50RLEUC, E40DRLAAA, E40DRLABA, E40DRLIIS, E40DRLINC, E40DRLISD, E40DRLISF, E40DRLSCB, E40DRLSDA, E40DRLSEE, E40DRLSOR, E40DRLSRC, E40DRLSUM, E40EEOD, E40EERE, E40JRECA, E40JREDC, E40JREOS, E40JREU
0341472
 
0341472 SUPPORT, Bracket
E45RCEOD, E45RCLEDS, E55RSLG, E55RSLW, HE55WMLM, SE40RPH
Back to top