0586034 VACUUM SWITCH EVINRUDE
BE150ELECD, BE150ELEDB, BE150ELEUC, BE175EXECD, BE175EXEDB, BE175EXEUC, BE200CXECM, BE200CXEDR, BE200CXEUA, BE225CXECS, BE225CXEDE, BE225CXEUD, BE250CXECB, BE250CXEDA, BE250CXEUM, E125WTPLE, E150ELEOM, E150WTLEOR, E175EXEOM, E200CXEOC, E200WPXEEN, E2
VACUUM
Price: query
Rating:
Compatible models:
BE150ELECD
BE150ELEDB
BE150ELEUC
BE175EXECD
BE175EXEDB
BE175EXEUC
BE200CXECM
BE200CXEDR
BE200CXEUA
BE225CXECS
BE225CXEDE
BE225CXEUD
BE250CXECB
BE250CXEDA
BE250CXEUM
E125WTPLE
E150ELEOM
E150WTLEOR
E175EXEOM
E200CXEOC
E200WPXEEN
E225CXEOB
E250CXECD
E250CXEOR
E300CXEOR
SE125WTPLJ
SE125WTPLN
SE125WTPLV
SE150WTPLB
SE150WTPLT
SE150WTPLY
SE200WTPLA
SE200WTPLG
SE200WTPLS
EVINRUDE
BRP EVINRUDE entire parts catalog list:
- FUEL BRACKET & COMPONENTS » 0586034
BE150ELEUC, BE150ELEUE, BE150EXEUC, BE150EXEUE, BE150GLEUC, BE150GLEUE, BE150NXEUC, BE150NXEUE, E150ELEUC, E150ELEUE, E150EXEUC, E150EXEUE, E150GLEUC, E150GLEUE, E150JLEUC, E150JLEUE, E150NXEUC, E150NXEUE, E150SLEUC, E150SLEUE, L150GLEUC, L150GLEUR 1997
BE175EXECD, BE175GLECD, BE175NXECD, E175EXECD, E175GLECD, E175NXECD, E175SLECD 1998
BE175EXEDB, BE175GLEDB, BE175NXEDB, E175EXEDB, E175GLEDB, E175NXEDB, E175SLEDB 1996
BE175EXEUC, BE175EXEUE, BE175GLEUC, BE175GLEUE, BE175NXEUC, BE175NXEUE, E175EXEUC, E175EXEUE, E175GLEUC, E175GLEUE, E175NXEUC, E175NXEUE, E175SLEUC, E175SLEUE 1997
BE200CXECM, BE200TXECM, E200CXECM, E200STLECE, E200TLECM, E200TXECM 1998
BE200CXEDR, BE200TXEDR, E200CXEDR, E200STLEDM, E200TXEDR, LE200SLEDR 1996
BE200CXEUA, BE200TXEUA, E200CXEUA, E200STLEUB, E200TXEUA 1997
BE225CXECS, BE225SLECS, BE225TXECS, E225CXECS, E225CZECS, E225STLECS, E225TXECS, E225TZECS, SE225GLECC, SE225NXECC, SE225NZECC, SE225QXECC, SE225QZECC 1998
BE225CXEDE, BE225PXEDE, BE225SLEDE, BE225TXEDE, E225CXEDE, E225CZEDE, E225PXEDE, E225STLEDE, E225TXEDE, E225TZEDE 1996
BE225CXEUD, BE225SLEUD, BE225TXEUD, E225CXEUD, E225CZEUD, E225STLEUD, E225TXEUD, E225TZEUD 1997
BE250CXECB, BE250TXECB 1998
BE250CXEDA, BE250TXEDA 1996
BE250CXEUM, BE250TXEUM 1997
E125WTPLE 1995
E150ELEOM, E150EXEOM, E150GLEOM, E150JLEOM, E150NXEOM, E150SLEOM, L150GLEOS, VE150HLEOS 1995
E150WTLEOR, E150WTXEOR 1995
E175EXEOM, E175GLEOM, E175NXEOM, E175SLEOM 1995
E200CXEOC, E200CZEOC, E200STLEOA, E200TXEOC, E200TZEOC, LE200SLEOC 1995
E200WPXEEN, E200WPXEES 1999
E225CXEOB, E225CZEOB, E225PXEOB, E225PZEOB, E225STLEOB, E225TXEOB, E225TZEOB 1995
E250CXECD, E250CZECD, E250PXECD, E250PZECD 1998
E250CXEOR, E250CZEOR, E250TXEOR, E250TZEOR 1995
E300CXEOR, E300PLEOR, E300PXEOR 1995
SE125WTPLJ, SE125WTPXJ 1997
SE125WTPLN, SE125WTPXN 1998
SE125WTPLV, SE125WTPXV 1996
SE150WTPLB, SE150WTPXB 1996
SE150WTPLT, SE150WTPLT4, SE150WTPXT, SE150WTPXT4 1997
SE150WTPLY, SE150WTPXY 1998
SE200WTPLA, SE200WTPXA 1996
SE200WTPLG, SE200WTPXG 1998
SE200WTPLS, SE200WTPXS 1997
Information:
Never service the air cleaner element with the engine running since this will allow dirt to enter the engine.
Servicing the Air Cleaner Elements
If the air cleaner element becomes plugged, the air can split the material of the air cleaner element. Unfiltered air will drastically accelerate internal engine wear. Your Caterpillar dealer has the proper air cleaner elements for your application. Consult your Caterpillar dealer for the correct air cleaner element.
Check the precleaner (if equipped) daily for accumulation of dirt and debris. Remove any dirt and debris, as needed.
Operating conditions (dust, dirt, and debris) may require more frequent service of the air cleaner element.
The air cleaner element may be cleaned up to six times if the element is properly cleaned and inspected.
The air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.Replace the dirty paper air cleaner elements with clean air cleaner elements. Before installation, the air cleaner elements should be thoroughly checked for tears and/or holes in the filter material. Inspect the gasket or the seal of the air cleaner element for damage. Maintain a supply of suitable air cleaner elements for replacement purposes.Dual Element Air Cleaners
The dual element air cleaner contains a primary air cleaner element and a secondary air cleaner element. The primary air cleaner element can be used up to six times if the element is properly cleaned and inspected. The primary air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.The secondary air cleaner element is not serviceable or washable. The secondary air cleaner element should be removed and discarded for every three cleanings of the primary air cleaner element. When the engine is operating in environments that are dusty or dirty, air cleaner elements may require more frequent replacement.
Illustration 1 g00736431
(1) Cover
(2) Primary air cleaner element
(3) Secondary air cleaner element
(4) Turbocharger air inlet
Remove the cover. Remove the primary air cleaner element.
The secondary air cleaner element should be removed and discarded for every three cleanings of the primary air cleaner element. Note: Refer to "Cleaning the Primary Air Cleaner Elements".
Cover the turbocharger air inlet with tape in order to keep out dirt.
Clean the inside of the air cleaner cover and body with a clean, dry cloth.
Remove the tape for the turbocharger air inlet. Install the secondary air cleaner element. Install a primary air cleaner element that is new or cleaned.
Install the air cleaner cover.
Reset the air cleaner service indicator. Cleaning the Primary Air Cleaner Elements
Caterpillar recommends certified air filter cleaning services that are available at Cat dealers. The Cat cleaning process uses proven procedures to assure consistent quality and sufficient filter life.Observe the following guidelines if you attempt to clean the filter element:Do not tap or strike the filter element in order to remove dust.Do not wash the filter element.Use low pressure compressed air in order to remove the dust from the filter element. Air pressure must not exceed 207 kPa (30 psi). Direct the air flow up the pleats and down the pleats from the inside of the filter element. Take extreme care in order to avoid damage to the pleats.Do not use air filters with damaged pleats, gaskets, or seals. Dirt entering the engine will cause damage to engine components.
The primary air cleaner element can be used up to six times if the element is properly cleaned and inspected. When the primary air cleaner element is cleaned, check for rips or tears in the filter material. The primary air cleaner element should be replaced at least one time per year. This replacement should be performed regardless of the number of cleanings.Use clean primary air cleaner elements while dirty elements are being cleaned.
Do not clean the air cleaner elements by bumping or tapping. This could damage the seals. Do not use elements with damaged pleats, gaskets or seals. Damaged elements will allow dirt to pass through. Engine damage could result.
Visually inspect the primary air cleaner elements before cleaning. Inspect the air cleaner elements for damage to the seal, the gaskets, and the outer cover. Discard any damaged air cleaner elements.There are two common methods that are used to clean primary air cleaner elements:
Pressurized air
Vacuum cleaningPressurized Air
Pressurized air can be used to clean primary air cleaner elements that have not been cleaned more than two times. Pressurized air will not remove deposits of carbon and oil. Use filtered, dry air with a maximum pressure of 207 kPa (30 psi).
Illustration 2 g00281692Note: When the primary air cleaner elements are cleaned, always begin with the clean side (inside) in order to force dirt particles toward the dirty side (outside).Aim the hose so that the air flows inside the element along the length of the filter in order to help prevent damage to the paper pleats. Do not aim the stream of air directly at the primary air cleaner element. Dirt could be forced further into the pleats.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Vacuum Cleaning
Vacuum cleaning is a good method for cleaning primary air cleaner elements which require daily cleaning because of a dry, dusty environment. Cleaning with pressurized air is recommended prior to vacuum cleaning. Vacuum cleaning will not remove deposits of carbon and oil.Note: Refer to "Inspecting the Primary Air Cleaner Elements".Inspecting the Primary Air Cleaner Elements
Illustration 3 g00281693Inspect the clean, dry primary air cleaner element. Use a 60 watt blue light in a dark room or in a similar facility. Place the blue light in the primary air cleaner element. Rotate the primary air cleaner element. Inspect the primary air cleaner element for tears and/or holes. Inspect the primary air cleane
Parts vacuum EVINRUDE: