0317818 WRIST PIN EVINRUDE
100990S, 115393M, 115493B, 115593, 115693D, 115790S, 115793S, 115890C, 135383M, 135443B, 135543E, 135643D, 150840S, 150940C, 175740S, 200640S, E100MLCSC, E115MLCIH, E115MLCSA, E140MLCIH, E140MLCSA, E150TRLCIA, E150TRLCSF, E175TRLCIM, E175TRLCSA, E200
WRIST
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BRP EVINRUDE entire parts catalog list:
- CRANKSHAFT & PISTON » 0317818
115493B 1974
115593 1975
115693D, 115693G, 115699D, 115699G 1976
115790S, 140740S, 140743S, 140783S, 85790S 1977
115793S, 115799S, 85793S, 85799S 1977
115890C, 115893C, 115899C, 140840C, 140843C, 140883C, 85890C, 85895C, 85899C 1978
135383M 1973
135443B, 135483B, 135489B 1974
135543E, 135583E, 135589E 1975
135643D, 135643G, 135683D, 135683G 1976
150840S, 150849S, 175840C, 175840S, 200840R, 200849R, 235840R, 235849R 1978
150940C, 150949C, 175940R, 175949R, 200490A, 200940A, 200949A, 235940A, 235949A 1979
175740S, 175749S, 200740C, 200749C 1977
200640S, 200649S 1976
E100MLCSC, E100TLCSC, E100TXCSC 1980
E115MLCIH, E115MLCIM, E115TLCIH, E115TLCIM, E115TXCIH, E115TXCIM 1981
E115MLCSA, E115TLCSA, E115TXCSA 1980
E140MLCIH, E140MLCIM, E140TRLCIH, E140TRLCIM, E140TRXCIH, E140TRXCIM 1981
E140MLCSA, E140TRLCSA, E140TRXCSA 1980
E150TRLCIA, E150TRLCIH, E150TRXCIA, E150TRXCIH 1981
E150TRLCSF, E150TRLCSR, E150TRXCSF, E150TRXCSR 1980
E175TRLCIM, E175TRXCIH, E175TRXCIM 1981
E175TRLCSA, E175TRLCSF, E175TRXCSA, E175TRXCSF 1980
E200TRLCIB, E200TRLCIH, E200TRXCIB, E200TRXCIH 1981
E200TRLCSF, E200TRLCSM, E200TRXCSF, E200TRXCSM 1980
E235TRLCIB, E235TRLCIH, E235TRXCIB, E235TRXCIH 1981
E235TRLCSM, E235TRXCSM 1980
E85MLCSA, E85STLCSA, E85STXCSA 1980
E90MLCIH, E90MLCIM, E90TLCIH, E90TLCIM, E90TXCIH, E90TXCIM 1981
Information:
Probable Causes
Switches
Batteries
Electric starting system (if equipped)
Air starting system (if equipped)
Hydraulic starting system (if equipped)
Flywheel ring gear
Driven equipment
Hydraulic cylinder lock
Worn engine componentsRecommended Actions
Table 1
Troubleshooting Test Steps Values Results
1. Inspect the Switches
A. Check the keyswitch input to the ECM.
B. Check engine shutdown switches.
C. Connect Cat® Electronic Technician (ET) to the service tool connector.
D. Use Cat ET to verify the status of the following parameters:
- Shutdown switches
Switches
Result: The switches are OK.
Proceed to Test Step 2.
Result: A switch is NOT OK.
Repair: Repair or replace damaged switch.
If the problem is not resolved, proceed to Test Step 2.
2. Inspect the Batteries
A. Charge the batteries, if necessary. Refer to Special Instruction, SEHS7633, "Battery Test Procedure" for additional information.
B. Load-test the batteries. Refer to Special Instruction, SEHS9249, "Use of 4C-4911 Battery Load Tester for 6, 8 V and 12 V Lead Acid Batteries" for additional information.
Batteries
Result: The batteries are OK.
Proceed to Test Step 3.
Result: The batteries are NOT OK.
Repair: Repair or replace the batteries.
If the problem is not resolved, proceed to Test Step 3.
3. Check the Electric Starting System
A. If the application is equipped with an electric starting system, perform the following procedure:
a. Check the wiring to the starting motor solenoid. Refer to the electrical schematic.
b. Check the engine start switch and the engine start relay for electrical power.
c. Check the starting motor cables. If the starting motor cables are corroded, remove the starting motor cables and clean the starting motor cables.
d. Test the operation of the starting motors.
Starter
Result: The electric starter is OK.
Proceed to Test Step 6.
Result: The electric starter is NOT OK.
Repair: Repair or replace damaged electric starter.
If the problem is not resolved, proceed to Test Step 6.
4. Check the Air Starting System
A. If the application is equipped with an air start system, perform the following procedure:
a. Verify that the air start system has an adequate supply pressure for starting.
b. Check the wiring to the air start relay that is for the air starting motors. Refer to the applications electrical schematic.
c. Check the engine start switch for electrical power.
d. Check the air start supply lines. If the supply lines are leaking or damaged, repair the lines.
e. Test the operation of the air start motors.
Starter
Result: The air starter is OK.
Proceed to Test Step 6.
Result: The air starter is NOT OK.
Repair: Repair or replace damaged air starter.
If the problem is not resolved, proceed to Test Step 6.
5. Check the Hydraulic Starting System
A. If the application is equipped with a hydraulic starting system, perform the following procedure:
a. Verify that the hydraulic starting system has an adequate supply pressure for starting.
b. Check the wiring to the start relay that is for the starting motors. Refer to the applications electrical schematic.
c. Check the engine start switch for electrical power.
d. Check the hydraulic starting lines. If the supply lines are leaking or damaged, repair the lines.
e. Test the operation of the hydraulic starting motors.
Starter
Result: The hydraulic starter is OK.
Proceed to Test Step 6.
Result: The hydraulic starter is NOT OK.
Repair: Repair or replace damaged hydraulic starter.
If the problem is not resolved, proceed to Test Step 6.
6. Inspect the Flywheel Ring Gear for Damage
Ring Gear
Result: The flywheel ring gear is OK.
Proceed to Test Step 7.
Result: The flywheel ring gear is NOT OK.
Repair: Repair or replace the ring gear.
If the problem is not resolved, proceed to Test Step 7.
7. Inspect the Driven Equipment
Driven Equipment
Result: The driven equipment is OK.
Proceed to Test Step 8.
Result: The driven equipment is NOT OK.
Repair: Repair or replace damaged driven equipment.
If the problem is not resolved, proceed to Test Step 8.
8. Check for Hydraulic Cylinder Lock
A. If an injector has been replaced, evacuate any fluids from the cylinder and attempt to start the engine. Fuel will flow from the cylinder head into the cylinders when a unit injector is removed.
B. If the engine will not start, check for fluid in the cylinders (hydraulic cylinder lock) by removing the individual unit injectors. Check for damaged seals. Determine the type of fluid that locked up the cylinder.
C. If there was a coolant leak, determine the cause of the leak.
D. If there was excessive fuel in the cylinder, replace the seals and reinstall the injector. Drain any excess fuel from the cylinder head.
Hydraulic Cylinder Lock
Result: The engine does not have a hydraulic cylinder lock.
Proceed to Test Step 9.
Result: The engine has a hydraulic cylinder lock.
Repair: Perform the necessary repairs.
If the problem is not resolved, proceed to Test Step 9.
9. Inspect the Engine for Internal Problems
A. If a mechanical problem is suspected, disassemble the engine. Refer to the Disassembly and Assembly manual for additional information.
B. Inspect the internal components for the following conditions:
- Seizure
- Broken components
- Bent components
Damaged or Worn Engine Components
Result: There are worn or damaged engine components.
Repair: Repair or replace the worn or damaged engine components.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Switches
Batteries
Electric starting system (if equipped)
Air starting system (if equipped)
Hydraulic starting system (if equipped)
Flywheel ring gear
Driven equipment
Hydraulic cylinder lock
Worn engine componentsRecommended Actions
Table 1
Troubleshooting Test Steps Values Results
1. Inspect the Switches
A. Check the keyswitch input to the ECM.
B. Check engine shutdown switches.
C. Connect Cat® Electronic Technician (ET) to the service tool connector.
D. Use Cat ET to verify the status of the following parameters:
- Shutdown switches
Switches
Result: The switches are OK.
Proceed to Test Step 2.
Result: A switch is NOT OK.
Repair: Repair or replace damaged switch.
If the problem is not resolved, proceed to Test Step 2.
2. Inspect the Batteries
A. Charge the batteries, if necessary. Refer to Special Instruction, SEHS7633, "Battery Test Procedure" for additional information.
B. Load-test the batteries. Refer to Special Instruction, SEHS9249, "Use of 4C-4911 Battery Load Tester for 6, 8 V and 12 V Lead Acid Batteries" for additional information.
Batteries
Result: The batteries are OK.
Proceed to Test Step 3.
Result: The batteries are NOT OK.
Repair: Repair or replace the batteries.
If the problem is not resolved, proceed to Test Step 3.
3. Check the Electric Starting System
A. If the application is equipped with an electric starting system, perform the following procedure:
a. Check the wiring to the starting motor solenoid. Refer to the electrical schematic.
b. Check the engine start switch and the engine start relay for electrical power.
c. Check the starting motor cables. If the starting motor cables are corroded, remove the starting motor cables and clean the starting motor cables.
d. Test the operation of the starting motors.
Starter
Result: The electric starter is OK.
Proceed to Test Step 6.
Result: The electric starter is NOT OK.
Repair: Repair or replace damaged electric starter.
If the problem is not resolved, proceed to Test Step 6.
4. Check the Air Starting System
A. If the application is equipped with an air start system, perform the following procedure:
a. Verify that the air start system has an adequate supply pressure for starting.
b. Check the wiring to the air start relay that is for the air starting motors. Refer to the applications electrical schematic.
c. Check the engine start switch for electrical power.
d. Check the air start supply lines. If the supply lines are leaking or damaged, repair the lines.
e. Test the operation of the air start motors.
Starter
Result: The air starter is OK.
Proceed to Test Step 6.
Result: The air starter is NOT OK.
Repair: Repair or replace damaged air starter.
If the problem is not resolved, proceed to Test Step 6.
5. Check the Hydraulic Starting System
A. If the application is equipped with a hydraulic starting system, perform the following procedure:
a. Verify that the hydraulic starting system has an adequate supply pressure for starting.
b. Check the wiring to the start relay that is for the starting motors. Refer to the applications electrical schematic.
c. Check the engine start switch for electrical power.
d. Check the hydraulic starting lines. If the supply lines are leaking or damaged, repair the lines.
e. Test the operation of the hydraulic starting motors.
Starter
Result: The hydraulic starter is OK.
Proceed to Test Step 6.
Result: The hydraulic starter is NOT OK.
Repair: Repair or replace damaged hydraulic starter.
If the problem is not resolved, proceed to Test Step 6.
6. Inspect the Flywheel Ring Gear for Damage
Ring Gear
Result: The flywheel ring gear is OK.
Proceed to Test Step 7.
Result: The flywheel ring gear is NOT OK.
Repair: Repair or replace the ring gear.
If the problem is not resolved, proceed to Test Step 7.
7. Inspect the Driven Equipment
Driven Equipment
Result: The driven equipment is OK.
Proceed to Test Step 8.
Result: The driven equipment is NOT OK.
Repair: Repair or replace damaged driven equipment.
If the problem is not resolved, proceed to Test Step 8.
8. Check for Hydraulic Cylinder Lock
A. If an injector has been replaced, evacuate any fluids from the cylinder and attempt to start the engine. Fuel will flow from the cylinder head into the cylinders when a unit injector is removed.
B. If the engine will not start, check for fluid in the cylinders (hydraulic cylinder lock) by removing the individual unit injectors. Check for damaged seals. Determine the type of fluid that locked up the cylinder.
C. If there was a coolant leak, determine the cause of the leak.
D. If there was excessive fuel in the cylinder, replace the seals and reinstall the injector. Drain any excess fuel from the cylinder head.
Hydraulic Cylinder Lock
Result: The engine does not have a hydraulic cylinder lock.
Proceed to Test Step 9.
Result: The engine has a hydraulic cylinder lock.
Repair: Perform the necessary repairs.
If the problem is not resolved, proceed to Test Step 9.
9. Inspect the Engine for Internal Problems
A. If a mechanical problem is suspected, disassemble the engine. Refer to the Disassembly and Assembly manual for additional information.
B. Inspect the internal components for the following conditions:
- Seizure
- Broken components
- Bent components
Damaged or Worn Engine Components
Result: There are worn or damaged engine components.
Repair: Repair or replace the worn or damaged engine components.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts wrist EVINRUDE:
0317819