FT11204 Force FORWARD BEARING CUP INSTALLER


FT11204 FORWARD BEARING CUP INSTALLER Force H0756H81G, H0756H82H, H0758H82E, H0850H79A, H0850H80A, H0850H81C, H0851H79A, H0851X88A, H0853F88B, H0853F89C, H0853F89E, H0853F89F, H0853F89G, H0855H79A, H0856A89A, H0856A89H, H0856B80H, H0856C87A, H0856C87B, H0856F84A, H0856F85A, H0856F86A, H0856H82 FORWARD
FT11204 FORWARD BEARING CUP INSTALLER Force
Rating:
18

Buy FORWARD BEARING CUP INSTALLER FT11204 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: &nbsp
 

Force entire parts catalog list:

H0756H81G 1981
H0756H82H 1982
H0758H82E 1982,1983,1984
H0850H79A 1979
H0850H80A 1980
H0850H81C 1981
H0851H79A 1979
H0851X88A 1988
H0853F88B 1988,1989
H0853F89C 1989
H0853F89E 1989
H0853F89F 1989
H0853F89G 1989
H0855H79A 1979
H0856A89A 1989
H0856A89H 1989
H0856B80H 1980
H0856C87A 1987
H0856C87B 1987
H0856F84A 1984
H0856F85A 1985
H0856F86A 1986
H0856H82K 1982,1983
H0856L89D 1989
H0856Y89B 1989
H0857H79G 1979
H0858B80C 1980
H0858B82E 1982
H0858C84H 1984
H0859B79B 1979
H085LD89A 1989
H085LD89B 1989
H085LD89C 1989
H0903F90B 1990
H0906A90A 1990
H0906R83D 1983,1984
H090LD90A 1990
H1000H79A 1979
H1004H79A 1979
H1006B80B 1980
H1006B81C 1981
H1007H79A 1979
H1008H80A 1980
H1008H83C 1983,1984
H1058H82G 1982
H1058V83H 1983
H1150H79A 1979
H1151H79A 1979
H1154B79A 1979
H1155H79A 1979
H1156H80C 1980
H1156H81D 1981
H1157B79B 1979
H1158B82E 1982
H1158H80D 1980
H1158H84G 1984
H1159H78B 1978
H1159H79C 1979
H120LD90A 1990
H1251A88A 1988
H1251A88B 1988
H1251A88C 1988
H1251A89A 1989
H1251A89B 1989
H1251A89C 1989
H1251A89D 1989
H1251A89E 1989
H1251F84A 1984
H1251F86A 1986
H1251F87A 1987
H1251F87B 1987
H1251X85A 1985
H1258H81A 1981,1982
H125LD89A 1989
H125LD89B 1989
H1400H79A 1979
H1401H79A 1979
H1405H79A 1979
H1406H80C 1980
H1406H81D 1981
H1407B79B 1979
H1408B80C 1980
H1408H82D 1982
H1408H83E 1983,1984
H1409H78A 1978
H1409H79B 1979

Information:


Table 1
Troubleshooting Test Steps Values Results
1. Determine the Fault
A. If an indicator other than the "POWER" indicator is illuminated when the electronic service tool is not communicating with an ECM, disconnect and reconnect the communication adapter. Communication problem Result: Both indicators on the communication adapter are not flashing.
Proceed to Test Step 2.
Result: The electronic service tool indicates that the engine is serviced on both links.
Proceed to Test Step 2.
Result: The electronic service tool displays a message that indicates the firmware in the communication adapter does not support communication on both data links.
Proceed to Test Step 3.
Result: The electronic service tool displays an Error"#142 The interface hardware is not responding" message.
Proceed to Test Step 3.
Result: The electronic service tool indicates that the electronic service tool cannot find an exact match for the software version in the ECM.
Repair: Update the electronic service tool to the latest available version.
Result: The power indicator is not illuminated.
Proceed to Test Step 5.
2. Verify that the Correct Communication Adapter is Being Used
A. A 317-7484 Communication Adapter Gp must be used to with a 370-4617 Cable As (USB) and a 457-6114 Cable As (Datalink Cable CA3) to communicate.
The following communication adapters cannot be used because the communication adapters do not communicate over both data links:
1. Wireless communication adapter
2. 7X-1701 Communication Adapter As
B. Determine the communication adapter that is being used.
Communication Adapter Result: An incorrect communication adapter is being used.
Repair: Connect a correct communication adapter. Refer to Troubleshooting, "Electronic Service Tools", if necessary.
Attempt to establish communication. Continue with this procedure if the communication adapter does not communicate on both data links.
Result: A correct communication adapter is being used. However, the "Power" indicator is not illuminated.
Proceed to Test Step 5.
Result: A correct communication adapter is being used. The "Power" indicator is illuminated.
Proceed to Test Step 4.
3. Check the Version of the Firmware for the Communication Adapter
The version of the firmware for the communication adapter must be "1.18.47" or higher.
A. Electronically disconnect the electronic service tool. Verify that the "power" indicator on the communication adapter is illuminated.
B. Click the "Utilities" menu.
C. Click the "Comm Adapter III Toolkit" menu.
D. Wait for the tool kit to open. Then, click the "Utilities" menu.
E. Click "Reprogram CA3".
F. Select the latest ".apf" file from the list.
G. Click "OK". Then, click "Begin Flash".
H. Wait for the "Flashes Completed Successfully" message to appear.
I. Click "Toolkit". Verify that the "Software Release Version" is "1.18.47" or higher.
J. Attempt to connect the electronic service tool. Firmware Result: The electronic service tool communicates on both data links.
The problem is resolved.
Result: The electronic service tool does not communicate on both data links.
Proceed to Test Step 4.
4. Check that the Electronic Service Tool is Configured Correctly
The electronic service tool must be configured correctly to communicate on both data links.
A. Click the "Utilities" menu.
B. Click the "Preferences" menu.
C. Select the "Communications" tab.
D. Verify that "Caterpillar Comm Adapter III (RP120)" is selected.
If "Caterpillar Comm Adapter III (RP120)" is not an option for selection, the version of the electronic service tool is incorrect. Version "2013B" or higher must be used.
Update the version of the electronic service tool and then perform this Test Step again.
E. Verify that the port is correct.
F. Verify that the "Enable Dual Data Link Service" option is checked.
G. Click "OK". The electronic service tool must reconnect in order for any changes to be used.
H. If changes are made to any of the settings for communications, electronically disconnect the electronic service tool . Electronically connect the electronic service tool. Attempt to establish communication. Observe the indicators on the communication adapter.
A "limited support" warning should not be displayed. The "J1939 / DeviceNet" and "CDL" indicators should be flashing. The indicator indicates that the electronic service tool is communicating on both data links. Configured Correctly Result: The electronic service tool communicates on both data links.
The problem is resolved.
Result: The electronic service tool does not communicate on both data links. The "POWER" indicator is not illuminated.
Proceed to Test Step 5.
Result: The electronic service tool does not communicate on both data links. The "POWER" indicator is illuminated.
Proceed to Test Step 6.
Illustration 1 g02061279
Power terminals at the service tool connector
(Terminal A) +Battery
(Terminal B) −Battery
Table 2
Troubleshooting Test Steps Values Results
5. Check the Electrical Power to the Communication Adapter
A. Check for battery voltage at the diagnostic connector. Electrical Power Result: Battery voltage is not present at the diagnostic connector.
Repair: Inspect the vehicles wiring and fuses. Determine the cause of the missing voltage. Make the necessary repairs.
Attempt to establish communication after the electrical power is at the service tool connector.
If the service tool does not communicate on both data links, proceed to Test Step 6.
Result: The electronic service tool indicates that the engine is serviced on both links.
Repair: Verify that the cable between the diagnostic connector and the communication adapter is OK. If necessary, replace the cable.
Repair: Replace the communication adapter if the following conditions are true:
1. There is power at the cables "DATA LINK" connector.
2. The communication adapters "POWER" indicator is not illuminated.
6. Check the Electrical Power to the ECM
A. Verify that the keyswitch is ON.
B. Check the voltage between the "Battery+" terminals and the "Battery-" terminals on the P1 ECM connector.
C. Check the voltage between the "Keyswitch" terminal and a "Battery-" terminal on the P1 ECM connector.
Electrical Power Result: Battery voltage is missing from a P1 terminal.
Repair: Inspect the vehicles wiring and fuses. Determine the cause of the missing voltage. Make the necessary repairs.
Attempt to establish communication after the electrical power is at all the appropriate P1 terminals. Continue with this procedure, if necessary.
Result: Battery voltage is present at all the appropriate P1 terminals.
Contact the Dealer Solutions Network (DSN).