48475 Force BUSHING


48475 BUSHING Force H040312RD, H040312SD, H040312UD, H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD BUSHING
48475 BUSHING Force
Rating:
103

Buy BUSHING 48475 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: 18
 

Force entire parts catalog list:

H040312RD 1995
H040312SD 1996,1997
H040312UD 1998,1999
H075412VD 1999
H090312RD 1995
H090412SD 1996,1997
H090412UD 1998
H090422VD 1999
H120412RD 1995
H120412SD 1996,1997
H120412UD 1998,1999

Information:


Illustration 1 g01160981
Schematic of the ether injection system
Breathing ether vapors or repeated contact of ether with skin can cause personal injury. Personal injury may occur from failure to adhere to the following procedures.Use ether only in well ventilated areas.Do not smoke while changing ether cylinders.Use ether with care to avoid fires.Do not store replacement ether cylinders in living areas or in the operator's compartment.Do not store ether cylinders in direct sunlight or at temperatures above 49 °C (120 °F).Discard cylinders in a safe place. Do not puncture or burn cylinders.Keep ether cylinders out of the reach of unauthorized personnel.To avoid possible injury, be sure the brakes are applied and all controls are in Hold or Neutral when starting the engine.
Test Step 1. Inspect the Electrical Connectors and the Wiring
Turn the keyswitch to the OFF position.
Illustration 2 g01144470
Left side engine view (typical example) (1) J1/P1 ECM connectors
Illustration 3 g01160988
Components for the ether injection system (typical location) (2) Ether injection solenoid
Thoroughly inspect connectors (1). Inspect the J504/P504 connectors for solenoid (2). Refer to Troubleshooting, "Electrical Connectors - Inspect".
Illustration 4 g01142845
P1 terminals for the ether injection system (P1-18) Solenoid return (ether start valve) (P1-20) Ether injection solenoid
Illustration 5 g01160725
P504 Ether start valve connector (P504-1) Ether start valve (P504-2) Solenoid return (ether start valve)
Perform a 45 N (10 lb) pull test on each of the wires that are associated with the ether injection system.
Check the torque of the allen head screws for the ECM connectors. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and the wiring for abrasion and for pinch points from the ether injection solenoid to the ECM.Expected Result:All connectors, pins, and sockets are completely coupled and/or inserted, and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The connectors and the wiring appear to be OK. Proceed to Test Step 2.
Not OK - The connectors and/or the wiring are not OK.Repair: Repair the connectors and/or the wiring. Replace parts, if necessary. Verify that the problem is resolved.STOPTest Step 2. Check for Active Diagnostic CodesNote: Remove the ether canister before you perform this procedure.
Connect Caterpillar Electronic Technician (ET) to the service tool connector. Refer to Troubleshooting, "Electronic Service Tools".
Turn the keyswitch to the ON position.
Proceed to the "Diagnostic Overrides" screen on Cat ET.
Activate the ether injection system. The system will activate for ten seconds.
Monitor the active diagnostic code screen on Cat ET. Wait at least 15 seconds in order for any diagnostic codes to become active. Look for these codes:
2417-05
2417-06Expected Result:No diagnostic codes are active.Results:
No active codes - Neither diagnostic code is active.Repair: The problem may have been caused by a poor electrical connection. Carefully reinspect the connectors and the wiring. Refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Active 2417-06 code - A 2417-06 code is active. Proceed to Test Step 3.
Active 2417-05 code - A 2417-05 code is active. Proceed to Test Step 4.Test Step 3. Create an Open at the Harness Connector for the Ether Injection Solenoid
Turn the keyswitch to the OFF position.
Disconnect the P504 connectors from the ether injection solenoid.
Turn the keyswitch to the ON position.
Proceed to the "Diagnostic Overrides" screen on Cat ET.
Activate the ether injection system. The system will activate for ten seconds.
Monitor the "Active Diagnostic Codes" screen on Cat ET. Wait at least 15 seconds in order for any diagnostic codes to become active. Look for an active 2417-05 code.
Turn the keyswitch to the OFF position.Expected Result:A 2417-05 code is now active.Results:
OK - A 2417-06 code was active before the connector was disconnected. A 2417-05 code became active after the connector was disconnected.Repair: Temporarily connect a new ether solenoid to the harness, but do not install the new ether solenoid. Verify that there are no active codes for the ether injection system.If there are no active codes for the ether injection system, permanently install the new solenoid. Clear any logged diagnostic codes.STOP
Not OK - A 2417-06 code was active before the connector was disconnected. The 2417-06 code remained active after the connector was disconnected. Do not connect the P504 connector to the ether injection solenoid. Proceed to Test Step 5.Test Step 4. Create a Short at the Connector for the Ether Injection Solenoid
Turn the keyswitch to the OFF position.
Disconnect the P504 connector from the ether injection solenoid.
Install a jumper wire between terminals 1 and 2 of the J504 harness connector.
Turn the keyswitch to the ON position.
Proceed to the "Diagnostic Overrides" screen on Cat ET.
Activate the ether injection system. The system will activate for ten seconds.
Monitor the "Active Diagnostic Codes" screen on Cat ET. Wait at least 15 seconds in order for any diagnostic codes to become active. Look for an active 2417-06 code.


Parts bushing Force:

812707
BUSHING
812707 BUSHING
H0091H84D, H009201RS, H009201SD, H009201UD, H009201US, H0092284D, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H015201RS, H015201US, H015211SS, H0152C84K, H0152S89A, H025201RD, H025201TD, H025201TS, H025201US, H040312RD, H040312SD, H040312UD, H0407E92
819513
 
819513 BUSHING
H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD, H1201A90A, H120412RD, H120412SD, H120412UD, H1501E89A
91912
 
91912 BUSHING
H0706A91B, H0903E91D, H0903E91H, H090LD90B, H090LD91D, H1201A90A, H120412RD, H120LD91B, H120LD91D, H120LD92B
26954
 
26954 BUSHING
H040312RD, H040312SD, H040312UD
822003
BUSHING
822003 BUSHING
H040312RD, H040312SD, H040312UD, H075312SD, H075312UD, H075412VD, H090412SD, H090412UD, H090422VD, H120412SD, H120412UD
823589
 
823589 BUSHING
H040312RD, H040312SD, H040312UD
821207
 
821207 BUSHING
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
65830
 
65830 BUSHING
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
Back to top