FK721706 COVER, GEAR HOUSING Force
H085LD89A, H085LD89B, H085LD89C, H0903E91H, H0906A90A, H090LD90A, H1201A90A, H120LD90A, H125LD89A, H125LD89B, H1501E89A
COVER
Price: query
Rating:
This part in 4 request:
Show.
This information for suppliers only!
#101428 FK721706
2023-05-17
#98903 FK721706
2022-09-17
#78681 FK721706
2020-11-13
#77576 FK721706
2020-09-25
Compatible models:
Force entire parts catalog list:
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
H090LD90A 1990
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
- GEAR HOUSING » FK721706
Information:
2W8915
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 2°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature increase of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 N m (38 6 lb ft)7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107 1.5°C (225 2°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature increase of 100°C (212°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft) 5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 2°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 1.5°C (198 2°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft) 3N7442
Low Water Temperature SwitchSwitch must open between ... 24 and 29°C (75 and 84°F)Switch must close between ... 18 and 24°C (64 and 75°F) 8N1693 For Ether Aid
Switch must open between ... 35 and 41°C (95 and 106°F)Switch must close ... 27°C (81°F min)Final installation tighten screws to a torque of ... 1.7 0.2 N m (15 2 lb in)Final torque for switch assembly ... 40 5 N m (29 4 lb ft)Pressure
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F) 2L3402
Current rating: 24 volts DC ... 4A32 volts DC ... 2AWith an increase in pressure, switch closes at ... 20.7 to 27.6 kPa (3 to 4 psi) 7N5946, For use with time delay and shutdown systems
Circuit 1: normally closedCircuit 2: normally openWith an increase in pressure, circuit 1 opens and circuit 2 closes at ... 145 kPa (21 psi) max.With a decrease in pressure, circuit 2 opens and circuit 1 closes at ... 75 20 kPa (11 3 psi) 3N7443, Alarm or Shutoff
With an increase of pressure, switch operates at ... 130 to 145 kPa (19 to 21 psi)With a decrease of pressure, switch operates at ... 105 to 110 kPa (15 to 16 psi)Starter Magnetic
Pull in voltage a 25° C ... 17 VCurrent consumption (draw) both windings at 24V ... 0.82 0.06 AType duty ... Intermittent(1) Torque for large terminal nuts ... 3.6 0.4 N m (31 4 lb in)(2) Torque for small terminal nuts ... 1.7 0.3 N m (15 3 lb in)
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 2°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature increase of 91°C (196°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 N m (38 6 lb ft)7C9365
Terminal No. 1 is normally open below actuation temperature.Terminal No. 2 is common.Terminal No. 3 is normally closed below actuation temperature.With a temperature increase of 107 1.5°C (225 2°F), terminal No. 1 closes and terminal No. 3 opens.With a temperature increase of 100°C (212°F), terminal No. 1 opens and terminal No. 3 closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft) 5N8857
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 98 1.5°C (208 2°F), terminal A closes and terminal C opens.With a temperature decrease of 91°C (196°F), terminal A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft)2W8916
Terminal A is normally open below actuation temperature.Terminal B is common.Terminal C is normally closed below actuation temperature.With a temperature increase of 92 1.5°C (198 2°F), terminal A closes and terminal C opens.With a temperature decrease of 85°C (185°F), terminal No. A opens and terminal C closes.(1) Final torque for switch assembly ... 52 8 N m (38 6 lb ft) 3N7442
Low Water Temperature SwitchSwitch must open between ... 24 and 29°C (75 and 84°F)Switch must close between ... 18 and 24°C (64 and 75°F) 8N1693 For Ether Aid
Switch must open between ... 35 and 41°C (95 and 106°F)Switch must close ... 27°C (81°F min)Final installation tighten screws to a torque of ... 1.7 0.2 N m (15 2 lb in)Final torque for switch assembly ... 40 5 N m (29 4 lb ft)Pressure
6T6652
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 103 kPa (15 psi).Terminal No. 3 is normally closed below 103 kPa (15 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 158 28 kPa (23 4 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 124 21 kPa (18 3 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F)9X4276
When installing switch, tighten to a maximum of ... 40 5 N m (29 4 lb ft)Terminal No. 1 is common.Terminal No. 2 is normally open below 48 kPa (7 psi).Terminal No. 3 is normally closed below 48 kPa (7 psi).With pressure increase, terminal No. 2 closes and terminal No. 3 opens at ... 93.0 20.8 kPa (13.5 3.0 psi)With pressure decrease, terminal No. 2 opens and terminal No. 3 closes at ... 68.9 20.8 kPa (10.0 3.0 psi)Temperature range (operating) ... -40 to 121°C (-40.0 to 250°F) 2L3402
Current rating: 24 volts DC ... 4A32 volts DC ... 2AWith an increase in pressure, switch closes at ... 20.7 to 27.6 kPa (3 to 4 psi) 7N5946, For use with time delay and shutdown systems
Circuit 1: normally closedCircuit 2: normally openWith an increase in pressure, circuit 1 opens and circuit 2 closes at ... 145 kPa (21 psi) max.With a decrease in pressure, circuit 2 opens and circuit 1 closes at ... 75 20 kPa (11 3 psi) 3N7443, Alarm or Shutoff
With an increase of pressure, switch operates at ... 130 to 145 kPa (19 to 21 psi)With a decrease of pressure, switch operates at ... 105 to 110 kPa (15 to 16 psi)Starter Magnetic
Pull in voltage a 25° C ... 17 VCurrent consumption (draw) both windings at 24V ... 0.82 0.06 AType duty ... Intermittent(1) Torque for large terminal nuts ... 3.6 0.4 N m (31 4 lb in)(2) Torque for small terminal nuts ... 1.7 0.3 N m (15 3 lb in)
Parts cover Force:
F476066-1
F476066-1 COVER, THERMOSTAT
H0700H79A, H0706A91B, H0709B79A, H0750H79A, H0756H80F, H0756H81G, H0756H82H, H0757B79E, H0757H76C, H0757H78D, H0758H80B, H0758H82E, H0759H79A, H0850H79A, H0850H80A, H0850H81C, H0851H79A, H0851X88A, H0853F88B, H0853F89C, H0853F89E, H0853F89F, H0853F89
F660995
F660995 COVER (ASSEMBLY-REMOTE CONTROL0
H0257F88A, H0257F88B, H0352F90B, H0352F90C, H0353E91A, H0353E91B, H0355D89A, H0356F89B, H0357C88B, H0357F88A, H0357F89C, H0357G90A, H0407E92C, H0504H88C, H0504H88D, H0505C89B, H0507A89C, H0507A89D, H0507A90A, H0507A90B, H0507A90C, H0507A90D, H0507A91
F664672
F664672 COVER, TERMINAL BLOCK COVER
H0851X88A, H0853F88B, H0853F89C, H0853F89E, H0853F89F, H0853F89G, H0856A89A, H0856A89H, H0856C87A, H0856C87B, H0856L89D, H0856Y89B, H085LD89A, H085LD89B, H085LD89C, H0903E91H, H0903F90B, H0903F90C, H0903F91A, H0903F91C, H0906A90A, H090LD90A, H1201A90
817802A 3
817802A 3 COVER
H0851X88A, H0853F88B, H0856C87B, H0903E91H, H0903F90B, H0903F91A, H0903F91C, H0906A90A, H1201A90A, H1251A88A, H1251A88B, H1251A88C, H1251A89A, H1251A89B, H1251A89C, H1251A89D, H1251A89E, H1251F87B, H1501E89A
F694995
819317F
FK719135F
F631707F