803910A99 DECAL SET Force
H075412VD, H090422VD
DECAL
Price: query
Rating:
Force entire parts catalog list:
Information:
Illustration 1 g00291249
Typical example
Note: All water temperature regulators do not have air vent valves (1). 119-3075 Water Temperature Regulator 126-5869 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 83 °C (172 ° to 181 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.75 mm (0.345 inch) 115-4223 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 102-8392 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 107-7568 Water Temperature Regulator 7E-5254 Water Temperature Regulator 119-3075 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 93 °C (199 °F)Begin to open temperature of the water temperature regulator. ... 79 ° to 82 °C (174 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 108-7045 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 93.9 °C (201.0 °F)Begin to open temperature of the water temperature regulator. ... 81.1 ° to 83.9 °C (178 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 7C-2190 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 97 °C (207 °F)Begin to open temperature of the water temperature regulator. ... 86 ° to 89 °C (187 ° to 192 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 30.5 0.5 mm (1.20 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch) 7E-1420 Water Temperature Regulator 9Y-3088 Water Temperature Regulator 9Y-3365 Water Temperature RegulatorFully open temperature of the water temperature regulator ... 94.4 °C (202 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 31.24 0.76 mm (1.230 0.030 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.1 mm (0.32 inch) 1W-8801 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 78 ° to 82 °C (172 ° to 180 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.5 0.5 mm (1.16 0.02 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.0 mm (0.32 inch) 1W-8802 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 94 °C (201 °F)Begin to open temperature of the water temperature regulator. ... 80 ° to 84 °C (176 ° to 183 °F) (1) Air vent valve (2) Closed dimension of the water temperature regulator ... 29.72 0.25 mm (1.170 0.010 inch) (3) Minimum stroke of the water temperature regulator at fully open temperature ... 8.13 mm (0.320 inch)
Illustration 2 g00589065
Typical example
4W-4011 Water Temperature Regulator 120-9453 Water Temperature Regulator 6I-4954 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 89 °C (192 °F)Begin to open temperature of the water temperature regulator. ... 75 ° to 78 °C (167 ° 172 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch) 4W-4794 Water Temperature Regulator Fully open temperature of the water temperature regulator ... 92 °C (198 °F)Begin to open temperature of the water temperature regulator. ... 81 ° to 84 °C (178 ° to 183 °F) (1) Minimum stroke of the water temperature regulator at fully open temperature ... 10.4 mm (0.41 inch)
Parts decal Force:
819526
819526 DECAL-Throttle Cable Adjust
H040312RD, H040312SD, H040312UD, H0407E92C, H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD, H1201A90A, H120412SD, H120412UD, H1501E89A
825064
825064 DECAL-Caution (Start In Gear)
H040312RD, H040312SD, H040312UD, H0407E92C, H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD, H1201A90A, H120412RD, H120412SD, H120412UD, H1501E89A
818029 1
818029 1 DECAL-Fuel Mix
H005201SD, H005201TS, H005201UD, H009201UD, H009201US, H015201US, H015211SS, H025201TD, H025201TS, H025201US, H040312UD, H075312UD, H075412VD, H090412UD, H090422VD, H120412UD
825149A 1
825149A 1 DECAL KIT-SHIFT TO NEUTRAL
H009201UD, H009201US, H015201US, H015211SS, H025201TD, H025201TS, H025201US, H040312UD, H075312UD, H075412VD, H090412UD, H090422VD, H120412UD
827282 2
827282 2 DECAL, Warning, Hi Voltage
H040312UD, H075312UD, H075412VD, H090412UD, H090422VD, H120412UD
855398A98
856985 16
856985 16 DECAL, EPA Label Information (Applied Top Of Block Near Exhaust Cover)
H075412VD, H090422VD
803188A99