F8559 Force DOWEL PIN


F8559 DOWEL PIN Force H0032H84G, H0042081C, H0042082D, H0042083E, H0042B78C, H0042B80G, H0042C84L, H0042C87A, H0042H77B, H0042H78D, H0042H78E, H0042H79F, H0043F85A, H005201RS, H005201SD, H005201TS, H005201UD, H0052C88A, H0054H76D, H0060B76A, H0060B78B, H0060H79C, H0060H80 DOWEL
F8559 DOWEL PIN Force
Rating:
48

Buy DOWEL PIN F8559 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: 31
 

Compatible models:

H0032H84G   H0042081C   H0042082D   H0042083E   H0042B78C   H0042B80G   H0042C84L   H0042C87A   H0042H77B   H0042H78D   H0042H78E   H0042H79F   H0043F85A   H005201RS   H005201SD   H005201TS   H005201UD   H0052C88A   H0054H76D   H0060B76A   H0060B78B   H0060H79C   H0060H80D   H0062B78J   H0062H79K   H0062H79M   H0064H78D   H0064H80F   H0064H82H   H0067H79C   H0070B79A   H0071H81B   H0071H82C   H0071H83D   H0071H84E   H0072B81D   H0072H79B   H0072H80C   H0072H82E   H0075H79A   H0082H76G   H0082H78J   H0082H79K   H0091B80B   H0091H79A   H0091H83C   H0091H84D   H009201RS   H009201SD   H009201UD   H009201US   H0092284D   H0092B80G   H0092H79F   H0092H81H   H0092H81J   H0092H83K   H0092H84L   H0092S88A   H0092S91A   H0093S91A   H0094H81F   H0095B80F   H0095B81G   H0095H82H   H0101B78A   H0102H76C   H0102H78E   H0121B79A   H0122H79E   H0125H79E   H015201RS   H015201US   H015211SS   H0152B78D   H0152B83J   H0152C84K   H0152H79E   H0152H80F   H0152H81G   H0152S89A   H0202B80L   H0202B81M   H0202H79K   H0202H82N   H025201RD   H025201TD   H025201TS   H025201US   H0252B83G   H0252H77B   H0252H78C   H0252H78D   H0254H75A   H0257F88A   H0257F88B   H0306B80C   H0307H81D   H0350H78L   H0351H76K   H0352F90B   H0352F90C   H0352H77H   H0352H79L   H0353E91A   H0353E91B   H0353H78K   H0353H80M   H0353H81N   H0353H82P   H0355D89A   H0356F89B   H0356H75F   H0357C86A   H0357C87A   H0357C88B   H0357F88A   H0357F89C   H0357G90A   H0357H83N   H040312RD   H040312SD   H040312UD   H0407E92C   H0456B78J   H0456B79K   H0456B80L   H0457H82N   H0457H83P   H0503B83A   H0503H84B   H0504H88C   H0504H88D   H0504P89B   H0505C89B   H0507A89C   H0507A89D   H0507A90A   H0507A90B   H0507A90C   H0507A90D   H0507A91A   H0507A91C   H0507A92A   H0507B85A   H0507C86A   H0507C87A   H0507C87C   H0507C88B   H0507E91B   H0507F87B   H0507F88A   H0507H81A   H0507H82B   H0507Z89B   H0555H74G   Force

Force entire parts catalog list:

H0032H84G 1984
H0042081C 1981
H0042082D 1982
H0042083E 1983
H0042B78C 1978
H0042B80G 1980
H0042C84L 1984
H0042C87A 1987
H0042H77B 1977
H0042H78D 1978
H0042H78E 1978
H0042H79F 1979
H0043F85A 1985,1986
H005201RS 1995
H005201SD 1996,1997
H005201TS 1997
H005201UD 1998,1999
H0052C88A 1988,1989,1990,1991,1992,1993,1994,1995
H0054H76D 1976
H0060B76A 1976
H0060B78B 1978
H0060H79C 1979
H0060H80D 1980
H0062B78J 1978
H0062H79K 1979
H0062H79M 1979
H0064H78D 1978
H0064H80F 1980
H0064H82H 1982
H0067H79C 1979
H0070B79A 1979
H0071H81B 1981
H0071H82C 1982
H0071H83D 1983
H0071H84E 1984,1985
H0072B81D 1981
H0072H79B 1979
H0072H80C 1980
H0072H82E 1982
H0075H79A 1979
H0082H76G 1976,1977
H0082H78J 1978
H0082H79K 1979
H0091B80B 1980
H0091H79A 1979
H0091H83C 1983
H0091H84D 1984
H009201RS 1995
H009201SD 1996,1997
H009201UD 1998
H009201US 1998
H0092284D 1984,1985,1986,1987,1988,1989,1990,1991,1992,1993,1994,1995
H0092B80G 1980
H0092H79F 1979
H0092H81H 1981
H0092H81J 1981,1982
H0092H83K 1983
H0092H84L 1984
H0092S88A 1988
H0092S91A 1991
H0093S91A 1991
H0094H81F 1981,1982
H0095B80F 1980
H0095B81G 1981
H0095H82H 1982
H0101B78A 1978
H0102H76C 1976,1977
H0102H78E 1978
H0121B79A 1979
H0122H79E 1979
H0125H79E 1979
H015201RS 1995
H015201US 1998
H015211SS 1996,1997
H0152B78D 1978
H0152B83J 1983,1984
H0152C84K 1984
H0152H79E 1979
H0152H80F 1980
H0152H81G 1981
H0152S89A 1989
H0202B80L 1980
H0202B81M 1981
H0202H79K 1979
H0202H82N 1982
H025201RD 1995,1996
H025201TD 1997
H025201TS 1997
H025201US 1998
H0252B83G 1983,1984
H0252H77B 1977
H0252H78C 1978
H0252H78D 1978
H0254H75A 1975,1976
H0257F88A 1988,1989
H0257F88B 1988,1989,1991
H0306B80C 1980
H0307H81D 1981
H0350H78L 1978

Information:


Table 1
Diagnostic Trouble Codes for the CAN Data Link Circuit
J1939 Code Code Description Comments
639-9 J1939 Network #1 : Abnormal Update Rate Another controller has incorrectly stopped transmitting an expected J1939 message or another controller has incorrectly started transmitting a conflicting J1939 message.
This diagnostic code applies to the CAN A datalink.
The ECM will log the diagnostic code.
The engine will not start.
1235-9 J1939 Network #3 : Abnormal Update Rate One of the following components has incorrectly stopped or started transmitting a data request:
• NOx sensors
• Diesel Exhaust Fluid (DEF) Tank Header Unit
• Diesel Oxidation Catalyst (DOC), Diesel Particulate Filter (DPF), or Selective Catalytic Reduction (SCR) inlet temperature sensor
This diagnostic code applies to the CAN C datalink.
The ECM will log the diagnostic code. The following background information is related to this procedure:The CAN data links are also known as J1939 data links. A data link is an industry standard for sending data between different devices in the same application.High-speed data is transferred via the data links. The data links cannot be accurately tested without complicated equipment. The data links require a resistance of 60 Ohms between the two wires to transmit the data correctly. This resistance is made up of two 120 Ohm resistors. The two resistors are known as "Terminating Resistors". The terminating resistors should be at opposite ends of a data link circuit. If this resistance is not present, then the data will be intermittent or unreadable.Note: The wiring for a J1939 data link is a shielded twisted-pair cable. If the wiring is damaged, the replacement type must be shielded twisted-pair cable.
Illustration 1 g06497597
Typical example of the schematic for the CAN A data link
Illustration 2 g06327401
Typical example of the schematic for the CAN C data link
Table 2
Troubleshooting Test Steps Values Results
1. Use the "System Communication Status to Check the Status of the Other Devices on the Suspect CAN Data Link"
A. In the electronic service tool, click the "Diagnostics" tab on the tool bar.
B. Select the "System Communication Status" option from the drop-down list.
Component Identified
Result: A 639-9 diagnostic code is active or logged.
Repair: Perform a full power-down of the application. Allow time for the DEF system to purge before turning the battery isolator to the OFF position.
Once the application is fully powered down, reapply power to the application. The 639-9 code will be reset.
Result: One or more of the devices on the suspect data link is not visible on the electronic service tool.
Repair: Thoroughly inspect the electrical connectors for the suspect devices
Refer to Troubleshooting, "Electrical Connectors - Inspect".
Check the power supply to the suspect devices.
If necessary, refer to Troubleshooting, "Electrical Power Supply - Test".
If the fault has been resolved, return the engine to service.
If the fault is still present, proceed to Test Step 2.
Result: All devices are visible on the electronic service tool.
Proceed to Test Step 2.
2. Check the Data Link Terminating Resistance
A. Disconnect the P1 connector and the P2 connector from the ECM.
B. Measure the resistance between P1:48 and P1:59. Measure the resistance between P2:102 and P2:80.
Between 50 Ohms and 70 Ohms
Result: The resistance is less than 50 Ohms - there is a short circuit in the harness.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all the seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair eliminates the fault.
Result: The resistance is between 110 and 130 Ohms - one of the terminating resistors may have failed.
Repair: Locate the two terminating resistors and remove the two terminating resistors from the harness. Depending on the application, one or both of the terminating resistors may be located in other ECMs on the data link.
Measure the resistance of the two terminating resistors.
If one of the terminating resistors is incorrect, replace the faulty terminating resistor.
If the two terminating resistors are between 110 and 130 Ohms, proceed to Test Step 4.
Result: The resistance is greater than 150 Ohms.
Proceed to Test Step 3.
Result: The resistance is between 50 and 70 Ohms
The resistance is correct. The fault may be in the connection to other devices on the data link.
Proceed to Test Step 3.
3. Check the Data Link Wiring
A. Disconnect each of the connectors that connect other devices on the data link.
B. Use a multimeter to measure the resistance between P1:48 and each of the CAN+ pins on other devices on the CAN A data link.
C. Use a multimeter to measure the resistance between P1:48 and pin (G) on the diagnostic connector.
D. Use a multimeter to measure the resistance between P1:59 and each of the CAN- pins on other devices on the CAN A data link.
E. Use a multimeter to measure the resistance between P1:59 and pin (F) on the diagnostic connector.
F. Use a multimeter to measure the resistance between P2:80 to each of the CAN+ pins on other devices on the CAN C data link.
G. Use a multimeter to measure the resistance between P2:102 to each of the CAN- pins on other devices on the CAN C data link.
Less than 2 Ohms
Result: At least one of the resistance measurements is greater than 2 Ohms - there is an open circuit or high resistance in the wiring.
Repair: Repair the connectors or the harness and/or replace the connectors or the harness.
Ensure that all seals are correctly in place and ensure that the connectors are correctly connected.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair has eliminated the fault.
Result: All measured resistances are less than 2 Ohms.
Proceed to Test Step 4.
4. Check the Other Devices on the CAN Data Link
A. Use the appropriate service tools to diagnose other devices on the data link.
Other devices are OK
Result: At least one of the other devices is not operating correctly.
Repair: Use the appropriate service tools to repair other devices on the data link.
Use the electronic service tool to clear all logged diagnostic codes and then verify that the repair eliminates the fault.
Result: The other devices are operating correctly.
Contact the