F499036-1 Force END-Control Rod (.250-28 LH)


F499036-1 END-Control Rod (.250-28 LH) Force H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD, H090LD90B, H090LD90C, H090LD91D, H1201A90A, H120412RD, H120412SD, H120412UD, H120LD91B, H120LD91D, H120LD92B, H1501E89A END
F499036-1 END-Control Rod (.250-28 LH) Force
Rating:
98

Buy END-Control Rod (.250-28 LH) F499036-1 Force genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$23.39
 

30-07-2022
0.1[0.05] Pounds
-: -
Mercury Marine New OEM LH Control End, F499036, F9036, F85036, F499036-1
Supersedes Part #s: F499036, F9036, F85036 || Sold Each || Please verify your own fitment
Number on catalog scheme: 17
 

Force entire parts catalog list:

H0706A91B 1991,1992,1993,1994,1995
H075312SD 1996,1997
H075312UD 1998
H075412VD 1999
H090312RD 1995
H0903E91H 1991,1992,1993,1994
H090412SD 1996,1997
H090412UD 1998
H090422VD 1999
H090LD90B 1990,1991
H090LD90C 1990
H090LD91D 1991
H1201A90A 1990,1991,1992,1993,1994
H120412RD 1995
H120412SD 1996,1997
H120412UD 1998,1999
H120LD91B 1991
H120LD91D 1991
H120LD92B 1992
H1501E89A 1989,1990,1991,1992,1993,1994

Information:

Troubleshooting
Troubleshooting can be difficult. On the following pages there is a list of possible problems. To make a repair to a problem, make reference to the cause and correction.This list of problems, causes and corrections will only give an indication of where a possible problem can be, and what repairs are needed. Normally, more or other repair work is needed beyond the recommendations in the list. Remember that a problem is not normally caused only by one part, but by the relation of one part with other parts. This list can not give all possible problems and corrections. The serviceman must find the problem and its source, then make the necessary repairs. Problems 1 through 5 are for troubleshooting the self-powered engine protection system. To troubleshoot the energized-to-run (ETR) protection systems, refer to Troubleshooting Guide (ETR), Form No. SENR3609.Problem Index
1. Contactor Switch (Water Temperature) Fails to Signal Shutoff.2. Contactor Switch (Water Temperature) Signals Shutoff at Low Temperature.3. Oil Pressure Contactor Fails to Signal Shutoff.4. Overspeed Contactor Switch Fails to Signal Shutoff.5. Overspeed Contactor Switch Signals Shutoff at Low Speed.Problem Checklist
Problem 1. Contactor Switch (Water Temperature) Fails To Signal Shutoff Probable Cause1. Incorrect Electrical Connections Check connections to other components or install new wiring. See WIRING DIAGRAM for SELF-POWERED PROTECTION in the WIRING DIAGRAMS section.2. Low Water Level in Cooling System Fill the cooling system.3. Incorrect Setting Test operation (trip) temperature setting and if necessary install new contactor switch with proper setting. See Specifications. Problem 2. Contactor Switch (Water Temperature) Signals Shutoff At Low Temperature Probable Cause1. Incorrect Setting Test operating (trip) temperature setting and if necessary install new contactor switch with proper setting. See Specifications. Problem 3. Oil Pressure Contactor Fails To Signal Shutoff Probable Cause1. Incorrect Electrical Connections See JUNCTION BOX WIRING DIAGRAM for SELF-POWERED PROTECTION in the WIRING DIAGRAMS section for the correct wiring connections.2. Incorrect Setting Test and adjust contactor. If necessary install new contactor switch. Problem 4. Overspeed Contactor Switch Fails To Signal Shutoff Probable Cause1. Incorrect Electrical Connections Check connection, wiring and correct where necessary. See WIRING DIAGRAM for SELF-POWERED PROTECTION in the WIRING DIAGRAMS section.2. Incorrect Setting Adjust setting or install new contactor switch with the correct rpm range if necessary. Problem 5. Overspeed Contactor Signals Shutoff At Low Speed Probable Cause1. Incorrect Setting Adjust setting or install new contactor switch with the correct rpm range if necessary.Mechanical Gauges For Temperature
To check these gauges, put the bulb of the gauge in a pan of oil. Do not let the bulb touch the pan. Put a thermometer in the oil to measure the temperature. Make a comparison of temperatures on the thermometer with the temperatures on the direct reading gauge.Mechanical Gauges For Oil Pressure
To check these gauges connect the gauge to a pressure source that can be measured with accuracy. Make a comparison of pressure on the gauge of test equipment with the pressure on the direct reading gauge.Contactor Switch For Water Temperature
Fabricated heat sink.2F7112 Thermometer.3J5389 Plug.8T500 Circuit Tester.1. Make a heat sink as shown. Material can be brass, steel or cast iron. Drill a 17.8 mm (.70 in.) hole through the plate and use a tap to make 1/2 in. NPT threads.2. Put marks on the two contactor wires that connect the contactor to the circuit. Disconnect the two wires.
Heat Sink [Dimensions in mm (in.)].3. Remove the contactor and install a 3J5389 Plug. Install the contactor switch in the heat sink.4. Put the heat sink and contactor in water as shown. Use blocks to support the heat sink at surface level.5. Connect the 8T500 Circuit Tester between the wires that connected the contactor to the circuit.
Test of Contactor Switch
(1) 2F7112 Thermometer. (2) Fabricated heat sink.6. Put the 2F7112 Thermometer in the water.7. Use a torch to heat the water to the temperature range at which the contactor must activate. If the circuit test light does not come on within the temperature range given in the Specifications make a replacement of the contactor.8. Let the water temperature go down. If the circuit tester light does not go out within the temperature range given in the Specifications make a replacement of the contactor.Mechanical Overspeed Switch
6B344 Tach Drive Adapter5L8164 Tach Drive Adapter6V7800 Multimeter1. Install 6B344 Tach Drive Adapter between the tach drive and the overspeed contactor. The 5L8184 Tach Drive Adapter must also be installed between the 6B344 Tach Drive Adapter and the overspeed contactor. The 6B344 Tach Drive Adapter provides a 1 to 2 increase drive ratio. The 5L8184 Tach Drive Adapter has a 1 to 1 drive ratio and is used only to provide clearance for the overspeed contactor.2. Determine the overspeed setting using the chart shown. For rated speed not shown in chart, use 118% of rated speed 25 rpm. 3. Identify (for reassembly) and disconnect harness wires from C (common) and NO (normally open) terminals of the overspeed contactor. Insulate each disconnected wire with tape.4. Reset the overspeed contactor


Parts end Force:

813448
 
813448 END CAP
H0407E92C, H0706A91B, H075312SD, H0903E91H, H1201A90A, H1501E89A
813452
END FRAME KIT
813452 END FRAME KIT
H0407E92C, H0706A91B, H075312SD, H0903E91H, H1201A90A, H1501E89A
F15189
 
F15189 END CAP
H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD, H090LD91D, H1201A90A, H120412RD, H120412SD, H120412UD, H120LD91D, H120LD92B, H1501E89A
813428
 
813428 END CAP ASSEMBLY
H090312RD, H090412SD, H120412RD, H120412SD
Back to top