T8930 1 Force FEELER GAUGE


T8930 1 FEELER GAUGE Force H0503B83A FEELER
T8930 1 FEELER GAUGE Force
Rating:
53

Buy FEELER GAUGE T8930 1 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: &nbsp
 

Compatible models:

H0503B83A   Force

Force entire parts catalog list:

H0503B83A 1983

Information:


Illustration 1 g02453536
Slide locking tab (2) into the unlocked position. Disconnect harness assembly (1) from differential pressure sensor (3).
Remove differential pressure sensor (3) from manifold (4).
Remove O-ring (5) (not shown) from differential pressure sensor (3).
Illustration 2 g02453736
Slide locking tab (6) into the unlocked position. Disconnect harness assembly (7) from absolute pressure sensor (8).
Remove absolute pressure sensor (8) from manifold (4).
Remove O-ring seal (9) (not shown) from pressure sensor (8).
Illustration 3 g02453877
Illustration 4 g02453879
If necessary, follow Step 7.a through Step 7.g in order to remove manifold (4) and tube assemblies from the NOx Reduction System (NRS) manifold.
Remove plastic breather tube from the crankcase breather cannister and the valve mechanism cover. Refer to Disassembly and Assembly, "Crankcase Breather- Remove" for the correct procedure.
Remove bolt (11) from tube assembly (13). Remove bolt (12) from clip for the tube assembly. Loosen hose clamp (14) from the hose for tube assembly (13).
Remove tube assembly (13) from manifold (4) and the NRS manifold. Remove O-ring seals (10) (not shown).
Remove bolt (15) from tube assembly (17). Remove bolt (18) from the clip for the tube assembly. Loosen hose clamp (23) from the hose for tube assembly (17).
Remove tube assembly (17) from manifold (4) and the NRS manifold. Remove O-ring seals (16) (not shown).
If necessary, remove connection (19) and connection (20) from the NRS manifold.
Cut cable strap (21) from harness assemblies. Remove bolts (22) from manifold (4). Remove the manifold from the inlet elbow. Installation Procedure
Ensure that wiring harness are correctly routed and the cable straps are not over tightened. Over tightening of the cable straps will damage the wiring harness convoluting.
Ensure that all components are clean and free from wear and damage. If necessary, replace any components that are worn or damaged. Ensure that all tube assemblies are clean and free from restriction.
Illustration 5 g02453879
Illustration 6 g02453877
If necessary, follow Step 2.a through Step 2.j in order to install manifold (4) and tube assemblies to the NOx Reduction System (NRS) manifold.
If necessary, install connection (19) and connection (20) NRS manifold. Tighten connections to a torque of 9 N m (80 lb in).
Position manifold (4) onto the inlet elbow. Install bolts (22). Tighten the bolts to a torque of 22 N m (195 lb in).
Install new O-ring seals (16) (not shown) onto tube assembly (17). Install tube assembly (17) into manifold (4) and install bolt (15).
Install hose for tube assembly (17) onto connection (20). Install bolt (18) for the clip for tube assembly (17).
Tighten bolt (18) and bolt (15) to a torque of 22 N m (195 lb in). Securely tighten hose clamp (23).
Install new O-ring seals (10) (not shown) onto tube assembly (13). Install tube assembly (13) into manifold (4) and install bolt (11).
Install hose for tube assembly (13) onto connection (19). Install bolt (12) to the clip for tube assembly (13).
Tighten bolt (11) and bolt (12) to a torque of 22 N m (195 lb in). Securely tighten hose clamp (14).
Install plastic breather tube to the crankcase breather cannister and the valve mechanism cover. Refer to Disassembly and Assembly, "Crankcase Breather- Install" for the correct procedure.
Install a new cable strap (21) to harness assemblies. Note: Ensure that cable straps meet the Original Equipment Manufactures (OEM) specification.
Illustration 7 g02453736
Install a new O-ring seal (9) (not shown) to pressure sensor (8). Note: Ensure that the O-ring seal is correctly seated onto the absolute pressure sensor.
Install absolute pressure sensor (8) to the manifold. Tighten the absolute pressure sensor to a torque of 10 N m (89 lb in).
Connect harness assembly (7) to absolute pressure sensor (8). Slide locking tab (6) into the locked position.
Illustration 8 g02453536
Install new O-ring seal (5) onto differential pressure sensor (3). Note: Ensure that the O-ring seal is correctly seated onto the differential pressure sensor.
Install differential pressure sensor (3) to manifold (4). Tighten the differential pressure sensor to a torque of 10 N m (89 lb in).
Connect harness assembly (1) to the differential pressure sensor. Slide locking tab (2) into the locked position.


Back to top