828998 Force FILTER-FUEL


828998 FILTER-FUEL Force H005201SD, H005201TS, H005201UD, H009201SD, H009201UD, H009201US, H0092S88A, H015201US, H015211SS FILTER
828998 FILTER-FUEL Force
Rating:
48

Buy FILTER-FUEL 828998 Force genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$104.95
 

18-01-2023

-: -
RaceQuip Roll Cage Net with Quick Release Right Side Triangle SFI 37.1 Certified Black 828998
SFI 37.1 Rated (Tags Affixed); Constructed of Premium 1" Polypropylene Webbing || Jig-built For Consistency || Side Net Prevents Head Movement || Uses a Heavy-Duty 2" Ratchet to Maintain Tension || Quick Release Stainless Steel Halyard Snap
Number on catalog scheme: 13
 

Force entire parts catalog list:

H005201SD 1996,1997
H005201TS 1997
H005201UD 1998,1999
H009201SD 1996,1997
H009201UD 1998
H009201US 1998
H0092S88A 1988
H015201US 1998
H015211SS 1996,1997

Information:


Operating units above the rating definitions will result in shorter service life before overhaul.
Industrial Rating Definitions
A Rating (Continuous)
* For heavy-duty service when engine is operated at rated load and speed up to 100 percent of the time without interruption or load cycling.* Time at full load up to 100 percent of the duty cycle.* Typical examples are: pipeline pumping, ventilation, and customer specifications.B Rating
* For service where power and/or speed are cyclic.* Time at full load not to exceed 80 percent of the duty cycle.* Typical examples are: irrigation where normal pump demand is 85 percent of the duty cycle, oil field mechanical pumping and drilling, and stationary/plant air compressors.C Rating (Intermittent)
* For service where power and/or speed are cyclic.* The horsepower and speed capability of the engine can be used for one uninterrupted hour, followed by one hour of operation at or below the A rating.* Time at full load not to exceed 50 percent of the duty cycle.* Typical examples are: agricultural tractors, harvesters and combines, off-highway trucks, fire pump application power, blast hole drills, rock crushers and wood chippers with high torque rise, and oil field hoisting.D Rating
* For service when rated power is required for periodic overloads.* The maximum horsepower and speed capability of the engine can be used for a maximum of 30 uninterrupted minutes, followed by one hour of followed by one hour of C rating operation.* Time at full load not to exceed 10 percent of the duty cycle.* Typical examples are: offshore cranes, runway snow blowers, water well drills, portable air compressors, and fire pump certification power.E Rating
* For service where rated power is required for a short time for initial starting or sudden overload. For emergency service where standard power is unavailable.* The maximum horsepower and speed capability of the engine can be utilized for a maximum of 15 uninterrupted minutes, followed by one hour at C rating operation, or for the duration of the emergency.* Time at full load is not to exceed 5 percent of the duty cycle.* Typical examples are: standby centrifugal water pumps, oil field well servicing, crash trucks, and gas turbine starters.Generator Set Engine Ratings
All ratings shown are subject to manufacturing tolerances of plus or minus three percent.Standby Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 100 or less.* Typical peak demand: 80 percent of the Standby rated kW, with 100 percent of the rating available for the duration of emergency outage* Typical Application: Building Service Standby within an enclosed sheltered environmentPrime Plus 10 Percent Rating
* Typical load factor: 60 percent or less.* Typical operating hours per year: 500 or less.* Typical peak demand: 80 percent of the Prime Plus 10 Percent rated kW, with 100 percent of the rating available for the duration of emergency outage.* Typical applications: Standby, Rental Unit, Power Module, Unreliable Utility, and Interruptible Rates.Prime Rating
* Typical load factor: 60 to 70 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated output is used for less than 10 percent of the operating hours.* Typical applications: Industrial, Pumping, Construction, Peak Shaving, and Cogeneration.Continuous Rating
* Typical load factor: 70 to 100 percent.* Typical operating hours per year: no limit.* Typical peak demand: 100 percent of the Continuous rated kW is used for less than 100 percent of the operating hours.* Typical application: Base Load, Utility, and Cogeneration.