F588 Force FLUSHING ADAPTER


F588 FLUSHING ADAPTER Force H0062H79K, H0062H79M, H0064H78D, H0067H79C, H0072H79B, H0082H76G, H0082H79K, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0094H81F, H0102H76C, H0102H78E, H0122H79E, H0152B78D, H0152H79E, H0152H80F, H0152H81G, H0202B80L, H0202H79K, H0252H77B, H0252H78 FLUSHING
F588 FLUSHING ADAPTER Force
Rating:
38

Buy FLUSHING ADAPTER F588 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: &nbsp
 

Force entire parts catalog list:

H0062H79K 1979
H0062H79M 1979
H0064H78D 1978
H0067H79C 1979
H0072H79B 1979
H0082H76G 1976,1977
H0082H79K 1979
H0092B80G 1980
H0092H79F 1979
H0092H81H 1981
H0092H81J 1981,1982
H0094H81F 1981,1982
H0102H76C 1976,1977
H0102H78E 1978
H0122H79E 1979
H0152B78D 1978
H0152H79E 1979
H0152H80F 1980
H0152H81G 1981
H0202B80L 1980
H0202H79K 1979
H0252H77B 1977
H0252H78C 1978
H0252H78D 1978
H0254H75A 1975,1976

Information:

Start By:
Prepare the machine for disassembly and assembly procedures. For additional information, refer to Disassembly and Assembly, "Preparation for Disassembly".Note: Put identification on all lines, hoses, wires, and tubes for installation purposes. Use caps and plugs on all lines, hoses, and tubes in order to prevent fluid loss or contamination of the systems.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Evacuate the air conditioning system.Reference: Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"Reference: Special Publication, NEDG5065, "Air Conditioning Tools"
Illustration 1 g00851713
Open the radiator grill.
Illustration 2 g00852277
Remove bolt (2) and the washer from the hose clip on hose assembly (1) .
Disconnect hose assemblies (1) and (4) .
Remove three bolts (3), the washers, and refrigerant condenser (5) .Installation Procedure
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Effective July 1, 1992 regulations prohibit the venting of any refrigerant into the atmosphere. Refer to Caterpillar publications Service Manuals, SENR3334, SENR5664, and NEDG5065 for the proper procedure, the proper equipment, and the proper tools needed in order to reclaim refrigerant from any Caterpillar equipment.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Illustration 3 g00852277
Install refrigerant condenser (5), three bolts (3), and the washers.
Connect hose assemblies (1) and (4) .
Position hose assembly (1) on refrigerant condenser (5). Install the hose clip, bolt (2), and the washer.
Illustration 4 g00851713
Close the radiator grill.
Charge the air conditioning system. The correct charge of refrigerant is approximately 1.2 kg (2.6 lb).Reference: Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134A Refrigerant"Reference: Special Publication, NEDG5065, "Air Conditioning Tools"


Back to top