F7011 Force ELASTIC STOP NUT, 10 - 24


F7011 ELASTIC STOP NUT, 10 - 24 Force H0033H75C, H0042081C, H0042082D, H0042083E, H0042C84L, H0043F85A, H005201RS, H005201SD, H005201TS, H005201UD, H0052C88A, H0060B76A, H0060B78B, H0060H79C, H0060H80D, H0062B78J, H0062H79K, H0062H79M, H0064H78D, H0064H80F, H0064H82H, H0067H79C, H0070B79 ELASTIC
F7011 ELASTIC STOP NUT, 10 - 24 Force
Rating:
93

Buy ELASTIC STOP NUT, 10 - 24 F7011 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: 47
 

Force entire parts catalog list:

H0033H75C 1975,1977
H0042081C 1981
H0042082D 1982
H0042083E 1983
H0042C84L 1984
H0043F85A 1985,1986
H005201RS 1995
H005201SD 1996,1997
H005201TS 1997
H005201UD 1998,1999
H0052C88A 1988,1989,1990,1991,1992,1993,1994,1995
H0060B76A 1976
H0060B78B 1978
H0060H79C 1979
H0060H80D 1980
H0062B78J 1978
H0062H79K 1979
H0062H79M 1979
H0064H78D 1978
H0064H80F 1980
H0064H82H 1982
H0067H79C 1979
H0070B79A 1979
H0071H81B 1981
H0071H82C 1982
H0071H83D 1983
H0071H84E 1984,1985
H0072B81D 1981
H0072H79B 1979
H0072H80C 1980
H0072H82E 1982
H0075H79A 1979
H0082H76G 1976,1977
H0082H78J 1978
H0082H79K 1979
H0091B80B 1980
H0091H79A 1979
H0091H83C 1983
H0091H84D 1984
H0092284D 1984,1985,1986,1987,1988,1989,1990,1991,1992,1993,1994,1995
H0092B80G 1980
H0092H79F 1979
H0092H81H 1981
H0092H81J 1981,1982
H0092H83K 1983
H0092H84L 1984
H0092S88A 1988
H0092S91A 1991
H0093S91A 1991
H0094H81F 1981,1982
H0095B81G 1981
H0095H82H 1982
H0101B78A 1978
H0102H76C 1976,1977
H0102H78E 1978
H0121B79A 1979
H0122H79E 1979
H0125H79E 1979
H0152B78D 1978
H0152B83J 1983,1984
H0152C84K 1984
H0152H79E 1979
H0152H80F 1980
H0152H81G 1981
H0152S89A 1989
H0202B80L 1980
H0202B81M 1981
H0202H79K 1979
H0202H82N 1982
H0252B83G 1983,1984
H0252H77B 1977
H0252H78C 1978
H0252H78D 1978

Information:


Table 1
Diagnostic Trouble Codes for the ARD Nozzle Heater    
CDL Code     Description     Notes    
3182-5     Aftertreatment #1 Fuel Injector #1 Heater : Current Below Normal     The Electronic Control Module (ECM) detects the following conditions:
A low current condition (open circuit) in the circuit for the Aftertreatment Regeneration Device (ARD) nozzle heater relay circuit for one second.
The ECM has been powered for at least one second.
The ECM is not attempting to power the ARD nozzle heater relay.    
3182-6     Aftertreatment #1 Fuel Injector #1 Heater : Current Above Normal     The ECM detects the following conditions:
A high current condition (short circuit) in the circuit for the ARD nozzle heater circuit for at least one second.
The ECM has been powered for at least one second.
The ECM is attempting to power the ARD nozzle heater relay.    The ARD nozzle can become plugged with carbon or with debris. The engine is equipped with a system that cleans the nozzle. The ECM periodically tests the condition of the nozzle. The ARD combustion head contains an electric heating element. The heating element operates periodically in order to clean the nozzle.ARD Nozzle Heater TestThe electronic service tool includes the "ARD Nozzle Heater Test". This override will assist the analysis of the ARD nozzle heater circuit. The override can be used to control the operation of the ARD nozzle heater while the engine is not running.
Illustration 1 g02453041
Schematic for the ARD nozzle heater
Illustration 2 g02041053
Pin locations on the P2 connector for the ARD nozzle heater (41) ARD nozzle heater relay return (43) ARD nozzle heater relay control
Illustration 3 g02169813
Pin locations on the 31-pin connector and the 40-pin connector for the ARD nozzle heater circuit
Illustration 4 g02474716
Control panel for the Clean Emissions Module (CEM) (1) 2-pin connector for the ARD nozzle heater (2) Relay for the ARD nozzle heater (3) Connector for the ARD nozzle heater relay (hidden)Test Step 1. Inspect Electrical Connectors And Wiring
Check that the fuses are not blown.
Check the harness for abrasion and pinch points from the ARD nozzle heater back to the ECM. Check the harness for abrasion and pinch points from the ARD nozzle heater back to the battery.
Inspect the connectors for the ARD heater and the ARD heater relay. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Thoroughly inspect the 31-pin connector and the 40-pin connector. Refer to Troubleshooting, "Electrical Connectors - Inspect".
Perform a 45 N (10 lb) pull test on each of the wires in the ECM connector and the connectors that are associated with the ARD nozzle heater.
Check the screw for the ECM connector for the correct torque of 6 N m (53 lb in).
Check the harness for abrasions and for pinch points from the heating element back to the ECM.Results:
All connectors, pins, and sockets are correctly coupled and/or inserted. The harness is free of corrosion, abrasion, and pinch points. The fuses are not blown. - Proceed to Test Step 2.
There is a fault with the harness and connectors - Repair: Repair the connectors or the harness and/or replace the connectors or the harness. Ensure that all of the seals are correctly in place and ensure that the connectors are correctly connected. Replace blown fuses.
Start the engine. Wait for the engine to reach operating temperature.
Use the electronic service tool to check for active diagnostic codes.
Do not energize the heater for more than 30 seconds. If the heater is energized more than 30 seconds, damage to the heater can occur. Allow the heating element to cool for 2 minutes between power cycles.
Use the "ARD Nozzle Heater Test" in the electronic service tool to switch on the ARD nozzle heater. Check for active diagnostic codes.
Confirm that the fault has been eliminated.Note: If a fuse is replaced and the fault reoccurs, continue with this procedure.STOPTest Step 2. Check for Active Diagnostic Codes
Connect the electronic service tool to the diagnostic connector.
Start the engine. Wait for the engine to reach operating temperature.
Check for an active 3182-5 diagnostic code.
Do not energize the heater for more than 30 seconds. If the heater is energized more than 30 seconds, damage to the heater can occur. Allow the heating element to cool for 2 minutes between power cycles.
Use the "ARD Nozzle Heater Test" in the electronic service tool to switch on the ARD nozzle heater. Check for an active 3182-6 diagnostic code.
Use the "ARD Nozzle Heater Test" in the electronic service tool to switch off the ARD nozzle heater.Results:
A 3182-5 diagnostic code is active or recently logged. - Proceed to Test Step 3.
A 3182-6 diagnostic code is active or recently logged. - Proceed to Test Step 6.
There are no active 3182 diagnostic codes. - There may be a fault with the switched power circuit for the ARD nozzle heater. The ECM does not monitor the status of this condition. Proceed to Test Step 11.Test Step 3. Create a Short at the ARD Nozzle Heater Relay
Turn the keyswitch to the OFF position.
Disconnect the connector for the ARD nozzle heater relay.
Fabricate a jumper wire that is 150 mm (6 in


Parts elastic Force:

F7001
 
F7001 ELASTIC STOP NUT
H0252H77B, H0252H78C, H0254H75A, H0351H76K, H0352H77H, H0352H79L, H0353H78K, H0353H80M, H0353H81N, H0353H82P, H0356H75F, H0456B78J, H0456B79K, H0555H74G, H0559H77H
F1910
 
F1910 ELASTIC STOP NUT, 1/4 - 20
H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75A, H0306B80C, H0307H81D, H0350H78L, H0351H76K, H0352H77H, H0352H79L, H0353H78K, H0353H80M, H0353H81N, H0353H82P, H0356H75F, H0357C86A, H0357H83N, H0456B78
F7005
 
F7005 ELASTIC STOP NUT
H0033H75C, H0042B78C, H0042B80G, H0042H77B, H0042H78D, H0042H78E, H0042H79F, H0054H76D, H0060B76A, H0062B78J, H0062H79K, H0062H79M, H0067H79C, H0072H79B, H0072H80C, H0082H76G, H0082H78J, H0082H79K, H0091B80B, H0091H79A, H0092B80G, H0092H79F, H0101B78
Back to top