F663366 Force MEDALLION, "FORCE"


F663366 MEDALLION, "FORCE" Force H0257F88A, H0257F88B, H0355D89A, H0356F89B, H0357C87A, H0357C88B, H0357F88A, H0357F89C, H0504H88C, H0504H88D, H0504P89B, H0505C89B, H0507A89C, H0507A89D, H0507C87A, H0507C87C, H0507C88B, H0507F87B, H0507F88A, H0507Z89B, H0851X88A, H0853F88B, H0853F89 MEDALLION
F663366 MEDALLION, "FORCE" Force
Rating:
98

Buy MEDALLION, "FORCE" F663366 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: 6
 

Force entire parts catalog list:

H0257F88A 1988,1989
H0257F88B 1988,1989,1991
H0355D89A 1989
H0356F89B 1989
H0357C87A 1987
H0357C88B 1988
H0357F88A 1988
H0357F89C 1989
H0504H88C 1988
H0504H88D 1988
H0504P89B 1989
H0505C89B 1989
H0507A89C 1989
H0507A89D 1989
H0507C87A 1987
H0507C87C 1987
H0507C88B 1988
H0507F87B 1987
H0507F88A 1988
H0507Z89B 1989
H0851X88A 1988
H0853F88B 1988,1989
H0853F89C 1989
H0853F89E 1989
H0853F89F 1989
H0853F89G 1989
H0856A89A 1989
H0856A89H 1989
H0856C87A 1987
H0856C87B 1987
H0856L89D 1989
H0856Y89B 1989
H1251A88A 1988
H1251A88B 1988
H1251A88C 1988
H1251A89A 1989
H1251A89B 1989
H1251A89C 1989
H1251A89D 1989
H1251A89E 1989
H1251F87A 1987
H1251F87B 1987

Information:

Starting The Engine
Woodward PSG Governor:
1. Perform all pre-start checks outlined previously. In addition, be sure the alternator and alternator belt are properly installed and adjusted.2. Push the START-STOP switch to the START position.3. When the engine starts, release the START-STOP switch. On some installations, low alternator output frequency will operate a relay to stop the starter. The alternator belts on these arrangements must be inspected regularly for proper belt tension and conditions.4. Start the load.5. Regulate the engine speed with the RAISE-LOWER switch to attain the required instrument panel gauge readings.Woodward UG8 Governor:
Start the engine as follows: If the governor is equipped with an electric motor, operate synchronizer knob (2) by using the RAISE-LOWER switch on the control panel. 1. Perform all pre-start checks outlined previously.2. Check the oil level in the sight level gauge with the engine stopped. Oil level should be near the top of the sight level gauge. See the LUBRICATION AND MAINTENANCE PROCEDURES, Section F. 3. Turn the load limit knob (3) until the indicator is between "5" and "7".
1-Droop knob. 2-Synchronizer knob. 3-Load limit knob. 4-Synchronizer Indicator. 5-Load pointer.4. Turn the synchronizer knob (2) clockwise until the indicator (4) is at "8".5. Move the START-STOP switch to the START position; start the engine.6. Run the engine at low idle for 5 minutes.7. Turn the load limit knob (3) to "10".8. Turn synchronizer knob (2) clockwise until the engine runs at full governed speed.9. Turn speed droop knob (1) to obtain proper droop for the operation: a. For single unit operation, set knob (1) at "0".b. For parallel operation: See Parallel Operation Droop Adjustment in the ELECTRIC SET OPERATION instructions. Speed droop knob (1) on the first unit on the line may be set at "0" droop, and the remaining units set between "30" and "70". These settings should provide constant speed or frequency. If constant speed is not required, set droop knob (1) on all units between "30" and "70".10. Apply the load and readjust the synchronizer knob (2) to obtain the desired load division. Load pointer (5) indicates the relative load.Stopping The Engine
1. Remove the load. See ELECTRIC SET OPERATION instructions if equipped with an electric set generator.2. Reduce engine speed to low idle: Push down and hold the RAISE-LOWER switch until the engine low idle speed is reached. When manually operating a UG8 Governor, move the synchronizer knob until the synchronizer indicator points to "8", or the low idle stop is reached. 3. While the engine is idling, check the engine oil level. Oil level must be maintained between the ADD and FULL mark on the side of the dipstick marked "CHECK WITH ENGINE RUNNING".4. Stop the engine. a. Solenoid Shutoff: Move the ON-OFF-STOP switch to the STOP position. Hold the switch until the engine stops. (Do not confuse this with the "RAISE-LOWER" switch.)
ON-OFF-STOP SWITCHb. PSG Governor: Move the shutoff lever forward, or hold the lever up, depending upon installation. Hold the lever in this position until the engine stops. c. UG8 Governor: Turn the load limit knob to "O". 5. Fill the fuel tank. See the LUBRICATION AND MAINTENANCE PROCEDURES, Section F.6. Drain the raw water system if below freezing temperatures are expected; see Section G.7. Observe the Service Meter reading. Perform the periodic maintenance as instructed in the LUBRICATION AND MAINTENANCE CHART.


Parts medallion Force:

F694366 1
 
F694366 1 MEDALLION-US MARINE (RED) (89A/91D)
H0091H84D, H0092284D, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H0152C84K, H0152S89A, H0407E92C, H0507A91A, H0507A91C, H0507A92A, H0507E91B, H0706A91B, H0851X88A, H0853F88B, H0903E91D, H0903E91H, H0903F91A, H0903F91C, H090LD90B, H090LD90C, H090LD91
F693366
 
F693366 MEDALLION-FORCE
H1251A89B, H1251A89C, H1251A89D, H1251A89E
Back to top