F7026 Force STOP NUT


F7026 STOP NUT Force H0032H84G, H0042081C, H0042082D, H0042083E, H0042C84L, H0043F85A, H005201RS, H005201SD, H005201TS, H005201UD, H0052C88A, H0064H82H, H0071H84E, H0072B81D, H0072H82E, H0091H83C, H0091H84D, H009201RS, H009201SD, H009201UD, H009201US, H0092284D, H0092H81 STOP
F7026 STOP NUT Force
Rating:
23

Buy STOP NUT F7026 Force genuine, new aftermarket parts with delivery
Number on catalog scheme: 14
 

Force entire parts catalog list:

H0032H84G 1984
H0042081C 1981
H0042082D 1982
H0042083E 1983
H0042C84L 1984
H0043F85A 1985,1986
H005201RS 1995
H005201SD 1996,1997
H005201TS 1997
H005201UD 1998,1999
H0052C88A 1988,1989,1990,1991,1992,1993,1994,1995
H0064H82H 1982
H0071H84E 1984,1985
H0072B81D 1981
H0072H82E 1982
H0091H83C 1983
H0091H84D 1984
H009201RS 1995
H009201SD 1996,1997
H009201UD 1998
H009201US 1998
H0092284D 1984,1985,1986,1987,1988,1989,1990,1991,1992,1993,1994,1995
H0092H81H 1981
H0092H81J 1981,1982
H0092H83K 1983
H0092H84L 1984
H0092S88A 1988
H0092S91A 1991
H0093S91A 1991
H0094H81F 1981,1982
H0095B81G 1981
H0095H82H 1982
H015201RS 1995
H015201US 1998
H015211SS 1996,1997
H0152B83J 1983,1984
H0152C84K 1984
H0152H81G 1981
H0152S89A 1989
H025201RD 1995,1996
H025201TD 1997
H025201TS 1997
H025201US 1998

Information:


Table 1
Default Minimum Maximum
0 minutes 1 minute 1440 minutes "Idle Shutdown Timer Maximum RPM"
This parameter resets the "Idle Shutdown Timer" if engine speed goes above the programmed "Idle Shutdown Timer Maximum RPM". Programming this parameter to 2120 rpm disables this feature. By disabling this feature, the "Idle Shutdown Timer" cannot be overridden by increasing the engine rpm. If this parameter is programmed to a value below 2120 rpm and the "PTO Shutdown Timer" is used, the timer will be reset when the engine rpm exceeds the programmed value.
Table 2
Default Minimum Maximum
2120 rpm 600 rpm 2120 rpm "Allow Idle Shutdown Override"
This parameter determines if the clutch or the service brake can be used to override the idle shutdown timer during the driver alert. The driver alert is the last 90 seconds when the check engine lamp begins flashing. This parameter requires the "Idle Shutdown Time" to be programmed to three or more minutes for the parameter to be enabled. When the "Idle Shutdown Time" is programmed to zero minutes, this feature is disabled.In order to override the timer under the following conditions, depress the clutch or the service brake if the parameter is programmed to "Outside Temperature Based" or "J1587 Outside Temperature Based" and the driver alert is activated. Depression of the clutch or the service brake will override the timer:
The outside temperature is below the programmed "Minimum Idle Shutdown Outside Temperature".
The outside temperature is above the" Maximum Idle Shutdown Outside Temperature".Note: The engine will not shut down when the timer is overridden.If the outside temperature is between the "Minimum Idle Shutdown Outside Temperature" and the "Maximum Idle Shutdown Outside Temperature", the timer is not overridden and the engine will shut down. If the "Outside Temperature Based" option is programmed, an air temperature sensor must be installed in order to measure the outside temperature.
Table 3
Default Alternative
Yes No
Outside Temperature Based
(J1587) Outside Temperature Based "Minimum Idle Shutdown Outside Temp"
This parameter determines the lower outside temperature limit when the "Allow Idle Shutdown Override" is programmed to one of the following options:
"Outside Temperature Based"
"J1587 Outside Temperature Based"
Table 4
Default Minimum Maximum
49 °C (120 °F) −40 °C (−40 °F) 49 °C (120 °F)
Illustration 1 g01261767
The "Allow Idle Shutdown Override" is programmed to the "Outside Temperature Based" option or to the "Outside Temperature Based (J1587)" option.
"Maximum Idle Shutdown Outside Temperature"
This parameter determines the upper outside temperature limit when the "Allow Idle Shutdown Override" is programmed to one option of the options that follow:
"Outside Temperature Based"
"J1587 Outside Temperature Based"Illustration 1 indicates that the "Allow Idle Shutdown Override" is allowed in the final 90 seconds of the timer's countdown. During the final 90 seconds, one of the following conditions must exist in order for the engine to be shut down:
The outside temperature is below the programmed "Minimum Idle Shutdown Outside Temperature".
The outside temperature is above the "Maximum Idle Shutdown Outside Temperature".
Table 5
Default Minimum Maximum
49 °C (120 °F) −40 °C (−40 °F) 49 °C (120 °F) "A/C Switch Fan-On Time"
Note: Program this parameter only when a normally closed high pressure A/C switch is connected to P1-41.The timer prevents excessive cycling of the cooling fan clutch due to successive cycling of the A/C switch. Programming this parameter to "0" disables the function.The ECM has a built-in timer. This parameter programs the duration of the timer. Programming depends on the refrigerant, and the design of the air conditioning system as well as the use of the signal input. Program the timer to one second when another system also provides a time delay.This feature requires the "Fan Control Type" to be programmed to any value except "None".
Table 6
Default Minimum Maximum
0 seconds 1 second 600 seconds "Engine Retarder Delay"
This parameter provides a programmable delay after provisions to turn on the engine retarder or the engine brake are met.
Table 7
Default Minimum Maximum
0 seconds


Parts stop Force:

F1997
 
F1997 STOP NUT, 8 - 32
H0091H83C, H0091H84D, H0092284D, H0092H81J, H0092H83K, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H0094H81F, H0095H82H, H0152B83J, H0152C84K, H0152S89A, H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75
F7004
 
F7004 STOP NUT, 3/8 - 16
H0071H81B, H0071H82C, H0071H83D, H0091H83C, H0091H84D, H0095B81G, H0095H82H, H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75A, H0257F88A, H0257F88B, H0306B80C, H0307H81D, H0350H78L, H0351H76K, H0352F90
F1804
 
F1804 STOP NUT, 10 - 32
H0033H75C, H0060B76A, H0062H79M, H0082H76G, H0082H79K, H0091B80B, H0091H79A, H0091H83C, H0091H84D, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0092H83K, H0092H84L, H0094H81F, H0101B78A, H0102H76C, H0102H78E, H0121B79A, H0122H79E, H0152B78D, H0152B83
F1803
 
F1803 STOP NUT
H0060B76A, H0062H79M, H0082H76G, H0082H79K, H0091B80B, H0091H79A, H0091H83C, H0091H84D, H009201SD, H0092284D, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0092H83K, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H0094H81F, H0095B80F, H0095B81G, H0095H82
F7024
 
F7024 STOP NUT
H0060B76A, H0060B78B, H0060H79C, H0060H80D, H0064H80F, H0070B79A, H0071H81B, H0071H82C, H0071H83D, H0075H79A, H0091B80B, H0091H79A, H0091H83C, H0091H84D, H0095B81G, H0095H82H, H0101B78A, H0121B79A, H0125H79E, H0202B80L, H0202B81M, H0202H79K, H0202H82
F702505
 
F702505 STOP, HIGH SPEED
H005201RS, H005201SD, H005201TS, H005201UD, H0052C88A
F702198
 
F702198 STOP, IDLE
H005201RS, H005201SD, H005201TS, H005201UD, H0052C88A
681490
 
681490 STOP, STARTER INTERIOCK
H0092S91A, H0093S91A
Back to top