Table 1
Diagnostic Codes Table
Code and Description Conditions which Generate this Code System Response
110-3 Engine Coolant Temperature Sensor : Voltage Above Normal The engine's Electronic Control Module (ECM) detects signal voltage that is more than 4.95 VDC for eight seconds.
The ECM has been powered for at least two seconds. The code is logged if the engine has been running for more than seven minutes. The ECM uses the last valid engine coolant temperature. If the diagnostic code is active at start-up the ECM will use intake manifold temperature. If intake manifold air temperature is not valid, the ECM will default to 90 °C (194 °F) for engine coolant temperature. The ECM will activate the cooling fan after this code has been active for more than eight seconds.
110-4 Engine Coolant Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for eight seconds.
The ECM has been powered for at least two seconds.
172-3 Intake Manifold Air Temperature Sensor : Voltage Above Normal The engine's ECM detects signal voltage that is more than 4.95 VDC for eight seconds.
The ECM has been powered for at least two seconds. The ECM will log the diagnostic code. The ECM will flag the intake manifold air temperature as invalid data and the intake manifold air temperature is set to a default value of 40 °C (104 °F).
172-4 Intake Manifold Air Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for eight seconds.
The ECM has been powered for at least two seconds.
174-3 Fuel Temperature Sensor : Voltage Above Normal The engine's ECM detects signal voltage that is more than 4.95 VDC for eight seconds.
The ECM has been powered for at least two seconds. The code is logged. The ECM will flag the fuel temperature as invalid data and the fuel temperature is set to a default value of 40 °C (104 °F).
174-4 Fuel Temperature Sensor : Voltage Below Normal The ECM detects signal voltage that is less than 0.2 VDC for two seconds.
The ECM has been powered for at least two seconds. System OperationUse this procedure to troubleshoot any suspect problems with the following sensors:
Coolant temperature sensor
Coolant temperature sensor (separate circuit)
Intake manifold air temperature sensor
Fuel temperature sensorThe sensor signal for the passive sensor is routed from the ECM to terminal 1 of each sensor connector. The sensor return for the passive sensors is routed from the ECM to terminal 2 of each sensor connector.
Illustration 1 g01684275
Schematic for the passive analog sensors
Illustration 2 g01684280
Terminal locations at the P2 ECM connector for the passive analog sensors
(P2-84) Engine coolant temperature
(P2-30) Analog sensor return
(P2-54) Analog sensor return
(P2-95) Intake manifold air temperature
(P2-96) Fuel temperature
Illustration 3 g01684375
Terminal locations at the P1 ECM connector for the passive analog sensors
(P1-3) Sensor return
(P1-17) Coolant temperature (separate circuit)
Illustration 4 g01155187
Terminal locations at the connector for the passive analog sensors
(Terminal 1) Sensor signal
(Terminal 2) Analog sensor return Test Step 1. CHECK FOR "ACTIVE" AND "LOGGED" DIAGNOSTIC CODES
Turn the keyswitch to the OFF position.
Connect Caterpillar Electronic Technician (ET) to the service tool connector.
Turn the keyswitch to the ON position.
Monitor the diagnostic codes on Cat ET. Check and record any diagnostic codes. Note: Wait at least 30 seconds in order for the diagnostic codes to become active.
Determine if a diagnostic code has occurred several times. Note: A diagnostic code that is logged several times is an indication of an intermittent problem. Most intermittent problems are the result of a poor connection between a socket and a pin in a connector or of a poor connection between a wire and a terminal.
Determine if the problem is active and related to one of the following diagnostic codes:
-3
-4Expected Result:A diagnostic code is not active.Results:
OK - A diagnostic code is not active.Repair: The problem may be intermittent. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".STOP
Not OK - An active -3 diagnostic code is present.
Parts stop Force:
F1997
F1997 STOP NUT, 8 - 32
H0091H83C, H0091H84D, H0092284D, H0092H81J, H0092H83K, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H0094H81F, H0095H82H, H0152B83J, H0152C84K, H0152S89A, H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75
F7007
F7007 STOP NUT, 5/16 - 18
H0257F88A, H0257F88B, H0352F90B, H0352F90C, H0352H77H, H0352H79L, H0353E91B, H0353H78K, H0353H80M, H0353H81N, H0353H82P, H0355D89A, H0356F89B, H0356H75F, H0357C88B, H0357F89C, H0357G90A, H0456B78J, H0456B79K, H0456B80L, H0457H82N, H0457H83P, H0503H84
F1669
F1669 STOP NUT
H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75A, H0257F88A, H0257F88B, H0306B80C, H0307H81D, H0350H78L, H0351H76K, H0352F90B, H0352F90C, H0352H77H, H0352H79L, H0353E91A, H0353E91B, H0353H78K, H0353H80
F7004
F7004 STOP NUT, 3/8 - 16
H0071H81B, H0071H82C, H0071H83D, H0091H83C, H0091H84D, H0095B81G, H0095H82H, H0202B80L, H0202B81M, H0202H79K, H0202H82N, H0252B83G, H0252H77B, H0252H78C, H0252H78D, H0254H75A, H0257F88A, H0257F88B, H0306B80C, H0307H81D, H0350H78L, H0351H76K, H0352F90
F1804
F1804 STOP NUT, 10 - 32
H0033H75C, H0060B76A, H0062H79M, H0082H76G, H0082H79K, H0091B80B, H0091H79A, H0091H83C, H0091H84D, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0092H83K, H0092H84L, H0094H81F, H0101B78A, H0102H76C, H0102H78E, H0121B79A, H0122H79E, H0152B78D, H0152B83
F1803
F1803 STOP NUT
H0060B76A, H0062H79M, H0082H76G, H0082H79K, H0091B80B, H0091H79A, H0091H83C, H0091H84D, H009201SD, H0092284D, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0092H83K, H0092H84L, H0092S88A, H0092S91A, H0093S91A, H0094H81F, H0095B80F, H0095B81G, H0095H82
F7008
F7008 STOP NUT, 1/4 - 20
H0091B80B, H0091H79A, H0091H83C, H0091H84D, H0092B80G, H0092H79F, H0092H81H, H0092H81J, H0095B81G, H0095H82H, H0101B78A, H0102H76C, H0102H78E, H0121B79A, H0122H79E, H0125H79E, H0152B78D, H0152B83J, H0152C84K, H0152H79E, H0152H80F, H0257F88A, H0257F88
F2093
F2093 STOP NUT 3/8 - 24
H0257F88A, H0257F88B, H0352F90B, H0352F90C, H0353E91A, H0353E91B, H0355D89A, H0356F89B, H0357C86A, H0357C87A, H0357C88B, H0357F88A, H0357F89C, H0357G90A, H0456B80L, H0457H82N, H0457H83P, H0503H84B, H0504H88C, H0504H88D, H0504P89B, H0505C89B, H0507A89