90350 2 Force STUD (M10 x 227)


90350 2 STUD (M10 x 227) Force H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD STUD
90350 2 STUD (M10 x 227) Force
Rating:
33

Buy STUD (M10 x 227) 90350 2 Force genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$2.92
 

17-11-2021
0.12[0.00] Pounds
-: -
Imperial 90350-2 Brass Pipe Thread Close Nipple, 1/8", Per Package Of 10
Pipe Thread: 1/8-27 || Dry seal pipe threads || Vibration resistance: fair || Working pressure up to 1,200 psi || Can be used with brass or iron pipe
Number on catalog scheme: 24
 

Force entire parts catalog list:

H075412VD 1999
H090312RD 1995
H090412SD 1996,1997
H090412UD 1998
H090422VD 1999
H120412RD 1995
H120412SD 1996,1997
H120412UD 1998,1999

Information:

Check Connectors for Moisture and Corrosion
Illustration 1 g01131211
Detail A illustrates the incorrect angle of wire entry into the connector. The wire should enter the connector at a perpendicular angle. (typical example)Inspect all the harnesses. Ensure that the routing of the wiring harness allows the wires to enter the face of each connector at a perpendicular angle. Otherwise, the wire will deform the seal bore. The damaged seal will create a path for the entrance of moisture. Verify that the seals for the wires are sealing correctly.
Illustration 2 g01131276
Diagram for the installation of a connector plug (typical example) (1) Electronic Control Module (ECM) connector (2) Correctly inserted plug (3) Incorrectly inserted plugEnsure that the sealing plugs are in place. If any of the plugs are missing, replace the plug. Ensure that the plugs are inserted correctly into the connector.
Illustration 3 g01131019
Seal for a three-pin connector (typical example)
Illustration 4 g01131165
Seal for the ECM connector (typical example)Disconnect the suspect connector and inspect the connector seal. Ensure that the seal is in good condition. If necessary, replace the connector.Thoroughly inspect the connectors for evidence of moisture entry.Note: Some minor seal abrasion on connector seals is normal. Minor seal abrasion will not allow the entry of moisture.If moisture or corrosion is evident in the connector, the source of the moisture entry must be found. The source of the moisture entry must be repaired. If the source of the moisture entry is not repaired, the fault will recur. Simply drying the connector will not fix the fault. Check the following items for the possible moisture entry path:
Missing seals
Incorrectly installed seals
Nicks in exposed insulation
Improperly mated connectorsMoisture can also travel to a connector through the inside of a wire. If moisture is found in a connector, thoroughly check the connector harness for damage. Also check other connectors that share the harness for moisture.Check the Wires for Damage to the Insulation
Carefully inspect each wire for signs of abrasion, nicks, and cuts.Inspect the wires for the following conditions:
Exposed insulation
Rubbing of a wire against the engine
Rubbing of a wire against a sharp pointCheck all of the fasteners for the harness and the ECM in order to verify that the harness is correctly secured. Also check all of the fasteners in order to verify that the harness is not compressed. Pull back the harness sleeves in order to check for a flattened portion of wire. A fastener that has been overtightened flattens the harness. This damages the wires that are inside the harness.Inspect the Connector Terminals
Visually inspect each terminal in the connector. Verify that the terminals are not damaged. Verify that the terminals are correctly aligned in the connector and verify that the terminals are correctly located in the connector.Perform a Pull Test on Each Wire Terminal Connection
Illustration 5 g01131435
Receptacle lock wedge (typical example)Ensure that the locking wedge for the connector is installed correctly. Terminals cannot be retained inside the connector if the locking wedge is not installed correctly.Perform the 45 N (10 lb) pull test on each wire. Each terminal and each connector should easily withstand 45 N (10 lb) of tension and each wire should remain in the connector body. This test checks whether the wire was correctly crimped in the terminal and whether the terminal was correctly inserted into the connector.Check Individual Pin Retention into the Socket
Illustration 6 g01131604
Diagram for testing pin retention (typical example)Verify that the sockets provide good retention for the pins. Insert a new pin into each socket one at a time in order to check for a good grip on the pin by the socket.Check the Locking Mechanism of the Connectors
Ensure that the connectors lock correctly. After you lock the connectors, ensure that the two halves cannot be pulled apart.Verify that the latch tab of the connector is correctly latched. Also verify that the latch tab of the connector returns to the locked position.Check the Allen Head Screws on the Connectors
Visually inspect the allen head screws for the ECM connectors. Ensure that the threads on each allen head screw are


Parts stud Force:

826393
 
826393 STUD (5/16-18 X 2-1/4") WITH DRI LOC
H0706A91B, H090312RD, H0903E91H, H1201A90A, H120412RD
826394
 
826394 STUD (3/8-16 x 3-27/32") With Dry Loc
H0706A91B, H075312SD, H075312UD, H075412VD, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD
826388
 
826388 STUD (5/16-18 X 1-1/4") WITH DRI LOC, CARBURETOR
H040312RD, H0407E92C, H090312RD, H0903E91H, H090412SD, H090412UD, H090422VD
820702 1
 
820702 1 STUD (M10)
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
90350 1
 
90350 1 STUD (M10 x 100)
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
90350 12
 
90350 12 STUD (M10 x 63)
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
90350 3
 
90350 3 STUD (M10 x 190)
H075412VD, H090312RD, H090412SD, H090412UD, H090422VD, H120412RD, H120412SD, H120412UD
42917 4
 
42917 4 STUD (M8 x 48)
H090312RD, H090412SD, H120412RD, H120412SD
Back to top