36123-ZW4-H12 Honda SEE PART DETAILS - PRI; ARMATURE


36123-ZW4-H12 SEE PART DETAILS - PRI; ARMATURE Honda BF25D4 LHTA, BF25D4 LRTA, BF25D4 SRTA, BF25D5 LHTA, BF25D5 LRTA, BF25D5 SRTA, BF25D6 LHTA, BF25D6 LRTA, BF25D6 SRTA, BF25DK0 LRTA, BF25DK2 LRTA, BF25DK3 LRTA, BF30D4 LHTA, BF30D4 LRTA, BF30D4 SRTA, BF30D5 LHTA, BF30D5 LRTA, BF30D5 SRTA, BF30D6 LHTA, SEE
36123-ZW4-H12 SEE PART DETAILS - PRI; ARMATURE Honda
Rating:
33

Buy SEE PART DETAILS - PRI; ARMATURE 36123-ZW4-H12 Honda genuine, new aftermarket parts with delivery
Number on catalog scheme: 6
 

Honda entire parts catalog list:

BF25D4 LHTA 2004
BF25D4 LRTA 2004
BF25D4 SRTA 2004
BF25D5 LHTA 2005
BF25D5 LRTA 2005
BF25D5 SRTA 2005
BF25D6 LHTA 2006
BF25D6 LRTA 2006
BF25D6 SRTA 2006
BF25DK0 LRTA 2007
BF25DK2 LRTA 2007
BF25DK3 LRTA 2007
BF30D4 LHTA 2004
BF30D4 LRTA 2004
BF30D4 SRTA 2004
BF30D5 LHTA 2005
BF30D5 LRTA 2005
BF30D5 SRTA 2005
BF30D6 LHTA 2006
BF30D6 LRTA 2006
BF30D6 SRTA 2006
BF30DK0 LRTA 2007
BF30DK0 SRTA 2007
BF30DK2 LRTA 2007
BF30DK2 SRTA 2007
BF30DK3 LRTA 2007
BF30DK3 SRTA 2007
BF40A6 LHTA 2006
BF40A6 LRTA 2006
BF40AK0 LRTA 2007
BF40DK2 LRTA 2007
BF50A6 LHTA 2006
BF50A6 LRTA 2006
BF50A6 SRJA 2006
BF50A6 XRTA 2006
BF50AK0 LRTA 2007
BF50AK0 SRJA 2007
BF50AK0 XRTA 2007
BF50DK2 LRTA 2007
BF50DK2 XRTA 2007
BF60AK1 LRTA 2007
BF60AK1 XRTA 2007
BFP60AK1 LRTA 2007
BFP60AK1 LRTB 2007
BFP60AK1 XRTA 2007

Information:


Table 1
Programmable Parameters for the Electronic Control Module (ECM) and the Air/Fuel Ratio Control (AFRC)
Cat ET
"C.S.P (CUSTOMER SPECIFIED PARAMETERS)"
AFRC "Desired Oxygen at Full Load"
AFRC "Governor Gain Factor"
AFRC "Governor Stability Factor"
AFRC "Governor Compensation Factor"
AFRC "Auxiliary Proportional Governor Gain 1"
AFRC "Auxiliary Integral Governor Gain 1"
AFRC "Auxiliary Derivative Governor Gain 1"
AFRC "Low Idle Speed"
AFRC "Rated Engine Speed"
AFRC "Engine Accel. Rate"
AFRC "Engine Speed Droop"
ECM "Engine Compression Ratio"
ECM "Number of Detonation Sensors"
ECM "Rating Number"
ECM "Engine Load Timing Map"
ECM "Engine Configuration"
AFRC "Engine Operation Type"
AFRC "Governor Type Setting"
"TIMING"
ECM "Desired Engine Ignition Timing"
"O2/TEST"
AFRC "Air/Fuel Proportional Gain"
AFRC "Air/Fuel Integral Gain" If a module is replaced, the appropriate parameters must be copied from the old module. The settings can be recorded on paper and then programmed into the new module. Alternatively, this can be done with the "Copy Configuration" feature of theCaterpillar Electronic Technician (Cat ET).
Changing the parameters during engine operation can cause the engine to operate erratically and can cause engine damage.Unless you are otherwise instructed, only change the settings of the parameters when the engine is STOPPED.
"C.S.P. Customer Specified Parameters"
"DES FULL LOAD O2"
This parameter is the desired percent of exhaust oxygen when the engine is at 100 percent of rated load. The programmed value is assumed to be a dry oxygen reading. The oxygen sensor actually measures a wet reading. The software in the ECM is programmed to compensate for the difference.Entering a higher value of desired oxygen will cause the engine to run lean, with a higher air/fuel ratio. Leaner running causes these conditions: reduced exhaust emissions, lower exhaust temperatures, slightly increased fuel consumption and decreased power reserve.Entering a lower value of desired oxygen will cause the engine to run on a richer mixture, with a lower air/fuel ratio. Richer running causes these conditions: greater exhaust emissions, higher exhaust temperatures, lower fuel consumption, and increased power reserve. If the air/fuel mixture is too rich, detonation can occur.Governor Gain Settings
The settings for the governor gains tailor the response of the governor to the application. There are individual adjustments for the proportional gain, the stability, and the compensation. These settings are also called proportional gain, integral gain, and derivative gain.There are primary gains and alternate gains. Two sets of gains allow the engine performance to be optimal under different conditions. For example, primary gains would be selected when the generator is on the grid. Alternate gains would be selected when the generator is off the grid.The primary gains are selected when terminal P1-35 on the ECM is an open circuit.The alternate gains are selected when terminal P1-35 is connected to ground."GOV P-GAIN"
This parameter is based on a proportional multiplier. This parameter determines the speed of the throttle actuator response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed."GOV STAB"
This parameter is based on an integral multiplier. This parameter controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping."GOV COMP"
This parameter is based on a derivative multiplier. This parameter is used to adjust for the time delay between the control signal and the movement of the throttle actuator. If this value is too low, the engine speed will slowly hunt. If this value is too high, the engine speed will rapidly fluctuate."AUX 1 GOV GAIN"
This parameter is based on a proportional multiplier. This parameter determines the speed of the throttle actuator response in adjusting for the difference between the actual speed and the desired speed. Increasing this value provides a faster response to the difference between the actual speed and the desired speed.This parameter changes the reaction of the throttle actuator when the "AUX 1 GOV GAINS" parameter is enabled. If changing this value causes no effect, check the "AUX 1 GOV GAINS" to make sure that the status is "ENABLED"."AUX 1 GOV STAB"
This parameter is based on an integral multiplier. This parameter controls the speed for elimination of the error in the difference between the actual speed and the desired speed. Increasing this value provides less damping.This parameter changes the reaction of the throttle actuator when the "AUX 1 GOV GAINS" parameter is enabled. If changing this value causes no effect, check the "AUX 1 GOV GAINS" to make sure that the status is "ENABLED"."AUX 1 GOV COMP"
This parameter is based on a derivative multiplier. This parameter is used to adjust for the time delay between the control signal and the movement of the throttle actuator. If this value is too low, the engine speed will slowly hunt. If this value is too high, the engine speed will rapidly fluctuate.This parameter changes the reaction of the throttle actuator when the "AUX 1 GOV GAINS" parameter is enabled. If changing this value causes no effect, check the "AUX 1 GOV GAINS" to make sure that the status is "ENABLED"."LOW IDLE SPEED"
This parameter sets the engine low idle speed. The valid range for this parameter is from 250 to 1500 rpm. The engine will attempt to maintain this speed when the idle/rated switch is in the idle position.This value for this parameter must be less than the value for the "RATED SPEED" parameter. If the value for the "LOW IDLE


Parts see Honda:

90122-ZV1-010
SEE PART DETAILS - PRI; BOLT, FLANGE (6X12) (Honda Code 7184005).
90122-ZV1-010 SEE PART DETAILS - PRI; BOLT, FLANGE (6X12) (Honda Code 7184005).
BF35AM LHA, BF35AM LRA, BF35AM LRTA, BF35AM SHA, BF35AM XRTA, BF40A1 LHA, BF40A1 LHTA, BF40A1 LRA, BF40A1 LRTA, BF40A1 XRTA, BF40A2 LHA, BF40A2 LHTA, BF40A2 LRA, BF40A2 LRTA, BF40A2 XRTA, BF40A3 LHA, BF40A3 LHTA, BF40A3 LRA, BF40A3 LRTA, BF40A3 XRTA,
13325-PZ1-003
 
13325-PZ1-003 SEE PART DETAILS - SUP; BEARING E, MAIN (YELLOW) (Honda Code 3701406). (DAIDO)
BF35AM LHA, BF35AM LRA, BF35AM LRTA, BF35AM SHA, BF35AM XRTA, BF40A1 LHA, BF40A1 LHTA, BF40A1 LRA, BF40A1 LRTA, BF40A1 XRTA, BF40A2 LHA, BF40A2 LHTA, BF40A2 LRA, BF40A2 LRTA, BF40A2 XRTA, BF40AW LHA, BF40AW LHTA, BF40AW LRA, BF40AW LRTA, BF40AW XRTA,
95701-06014-02
SEE PART DETAILS - PRI; BOLT, FLANGE (6X14) (Honda Code 3707114).
95701-06014-02 SEE PART DETAILS - PRI; BOLT, FLANGE (6X14) (Honda Code 3707114).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115AX LA, BF115AX LCA, BF115AX XA, BF115AX XCA, BF115AY LA, BF115AY LCA, BF115AY XA, BF115AY XCA, BF130A1 LA, BF130A1 LCA, BF130A1 XA, BF130A1 XCA,
87703-ZW5-U01
 
87703-ZW5-U01 SEE PART DETAILS - SUP; MARK, REMOTE CONTROL TOP MOUNT (Honda Code 6810824). SINGLE
BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF150A4 LA, BF150A4 XA, BF150A4 XCA, BF150A5 LA, BF150A5 XA, BF150A5 XCA, BF150A6 LA, BF150A6 XA, B
37250-ZV7-913
SEE PART DETAILS - PRI; TACHOMETER ASSY.
37250-ZV7-913 SEE PART DETAILS - PRI; TACHOMETER ASSY.
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
35618-ZW9-010
SEE PART DETAILS - PRI; PLATE, NEUTRAL SW
35618-ZW9-010 SEE PART DETAILS - PRI; PLATE, NEUTRAL SW
BF15DK0 LHSA, BF15DK0 LHTA, BF15DK0 LRTA, BF15DK0 SHSA, BF15DK0 SHTA, BF15DK2 LHSA, BF15DK2 LHTA, BF15DK2 LRTA, BF15DK2 SHSA, BF15DK2 SHTA, BF15DK3 LHSA, BF15DK3 LHTA, BF15DK3 LRTA, BF15DK3 SHSA, BF15DK3 SHTA, BF20DK0 LHTA, BF20DK0 LRTA, BF20DK0 SHTA
90602-ZV3-020
SEE PART DETAILS - SUP; CLAMP, TUBE (D18.8) (Honda Code 8673659).
90602-ZV3-020 SEE PART DETAILS - SUP; CLAMP, TUBE (D18.8) (Honda Code 8673659).
BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA, BF115A6 LA, BF115A6 LCA, BF115A6 XA, BF115A6 XCA, BF115AK0 LA, BF115AK0 XA, BF130A3 LA, BF130A3 LCA,
91301-ZV7-010
SEE PART DETAILS - PRI; O-RING, PUMP COVER
91301-ZV7-010 SEE PART DETAILS - PRI; O-RING, PUMP COVER
BF25A1 LHA, BF25A1 LHSA, BF25A1 LRSA, BF25A1 SHA, BF25A1 SHSA, BF25A1 SRSA, BF25A1 XRSA, BF25A2 LHA, BF25A2 LHSA, BF25A2 LRSA, BF25A2 SHA, BF25A2 SHSA, BF25A2 SRSA, BF25A2 XRSA, BF25A3 LHA, BF25A3 LHSA, BF25A3 LRSA, BF25A3 SHA, BF25A3 SHSA, BF25A3 SR
Back to top