13213-PWA-003 Honda BEARING C, CONNECTING ROD (BROWN) (DAIDO)


13213-PWA-003 BEARING C, CONNECTING ROD (BROWN) (DAIDO) Honda BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA BEARING
13213-PWA-003 BEARING C, CONNECTING ROD (BROWN) (DAIDO) Honda
Rating:
93

Buy BEARING C, CONNECTING ROD (BROWN) (DAIDO) 13213-PWA-003 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$27.29
 

12-11-2023
0.5625[0.25] pounds
-: -
Genuine Honda 13213-PWA-003 Connecting Rod Bearing
Fit '09-'12 (KA/KC/KX) || Genuine OEM || Direct fit || Genuine Honda Parts 13213-PWA-003 Connecting Rod (Brown) Bearing C
 
$22.59
 

24-09-2017

Acura: Acura
Acura 13213-PWA-003 Engine Connecting Rod Bearing
Genuine Acura OEM product
Number on catalog scheme: 6
 

Honda entire parts catalog list:

BF60AK1 LRTA 2007
BF60AK1 XRTA 2007
BF75DK0 LHTA 2007
BF75DK0 LRTA 2007
BF75DK2 LRTA 2007
BF90DK0 LHTA 2007
BF90DK0 LRTA 2007
BF90DK0 XRTA 2007
BF90DK2 LRTA 2007
BF90DK2 XRTA 2007
BFP60AK1 LRTA 2007
BFP60AK1 LRTB 2007
BFP60AK1 XRTA 2007

Information:

General Troubleshooting And Repair Of The Engine Horsepower Meter And Accessories
General Troubleshooting Procedure
The following section gives a general procedure for isolating a faulty portion of the entire Engine Horsepower Meter Arrangement. It is written to enable a person with reasonable knowledge of electricity and a multimeter to find simple faults which are field repairable, without taking the unit to an electronics repair facility or returning it to the manufacturer.If the following procedure does not isolate the problem, U.S. dealers should return the unit (Horsepower Meter or flowmeter only) to the appropriate address shown on page 49. Dealers outside the U.S. may wish to have the unit further inspected and repaired locally by a qualified electronics shop which is familiar with digital circuitry.The material on pages 20-23 and pages 26-48 is intended only for those situations where it is not practical to return the unit to the U.S. for repair. U.S. dealers are urged to send their units to Fluidyne Instrumentation where repairs and calibration can be performed more precisely and efficiently. Be sure to check out the components by using the following procedure in the order indicated. Do not omit any tests unless the unit is known to operate correctly in that specific mode.
Do not use a continuity light to trace circuits on either printed circuit board. Some semiconductor components can be damaged if 3 volts is connected across them.
1. Turn the POWER switch to ON (Be sure the knob has not slipped on the shaft).2. Do any of the display lights light? a) YES - Go to Step 3.b) NO - Open the Horsepower Meter and perform the steps shown on page 6. If the problem cannot be identified as a blown fuse, bad switch contact, broken wire, loose battery connection, dead batteries, etc., return the unit to Fluidyne Instrumentation (see page 49). If the problem is known to be in the power board, return only the power board to Fluidyne.3. Are the display lights dim? a) NO - Go to Step 4.b) YES - Check for a voltage at the batteries of greater than 5.2 volts. If the voltage is less, recharge the batteries to over 6 volts and recheck. (If the batteries won't charge, go to Step 15.) Check for voltage losses between the batteries and wiring point 16 and the displays. The voltage should be greater than 5 volts at wiring point 16.4. Do any of the lights have the correct brilliance? a) YES - Go to Step 5.b) NO - Review Step 2. If the problem cannot be found, return the unit to Fluidyne.5. If all digits light correctly, go to Step 6. Individual lamps or related 7447's (integrated circuits) may fail while most digits work properly. Interchange known good components with suspected components. See page 24. Be sure to remove the plug-in lights carefully so they separate correctly from their sockets. Replacement lamps and 7447's are available from Fluidyne. If any soldered component is suspected, return the entire unit to Fluidyne.6. With the POWER switch ON, turn the MODE switch to the BATT. TEST position (be sure the knob has not slipped on the shaft). Is the displayed value greater than 5.0 volts? a) YES - The power supply circuit and displays are basically operational. Go to Step 7.b) NO - Review Step 2. If the problem cannot be found, return the unit to Fluidyne.7. If the BATT. TEST value is less than 5.80 volts, recharge the batteries so there is sufficient power to complete the remaining tests. If the batteries cannot be charged, Step 15.8. Turn the MODE switch to the ENGINE SPEED VERIFY position. Is 6000 rpm displayed? a) YES - The tachometer circuit in the Horsepower Meter is operational. Go to Step 9.b) NO - Is only one digit wrong? (1) YES - See step 5.(2) NO - Check for broken wires, a broken switch, etc. If no physical defects can be seen, an oscilliscope is needed for more testing. Return the unit to Fluidyne. A tachometer circuit defect will not affect the flow rate readings or horsepower tests.9. Connect the Tachometer Generator and RPM cable to the Horsepower Meter. Turn the MODE switch to any position except ENGINE SPEED VERIFY. Spin the generator shaft by hand. Is a fluctuating reading displayed (approximately 300 - 500 rpm)? a) YES - All tachometer components are basically operational. If difficulty is encountered while running on an engine, check the tachometer generator and adjustment (see the NOTE below and page 8). Be sure to install the generator only finger-tight and check that the tachometer drive ratio is correct (shaft running at 1/2 engine speed). Electrical noise (from older electric sets) can be eliminated by using a shielded 9S3048 Cable Assembly between the tachometer generator and the 5P2159 Cable. If the tachometer circuit is correct while running an engine, go to Step 10.b) NO - Check the rpm cable for continuity and for shorts, and the tachometer generator (see page 13). If the generator and cable check is satisfactory, look for obvious physical defects in the readout box. If none can be seen, return the unit to Fluidyne. Pin A of the threaded connector of the rpm cable should be connected to the center terminal of the phone jack on the opposite end. Some cables may be assembled wrong.10. Turn the MODE switch to the GAL/HR CALIB. position. If the unit has been turned on for at least 5 minutes, is the GAL/HR CALIB. value (top display) stable and within the tolerance given on the lid of the unit? a) YES - The gallons per hour circuitry is basically operational. Go to Step 11.b) NO - If the value is within 1.0 gph, the unit may simply need to be calibrated. See pages 9 - 12. Special electronic equipment is needed for calibration (see page 11), so it is suggested that the unit be returned to Fluidyne for correct calibration. It is also possible that the Digital-to-Analog Converter (DAC) is malfunctioning.


Parts bearing Honda:

91052-ZW1-B02
BEARING, NEEDLE (Honda Code 5743794). (1-1/8X1-1/2X1-1/4)
91052-ZW1-B02 BEARING, NEEDLE (Honda Code 5743794). (1-1/8X1-1/2X1-1/4)
BF75A1 LHTA, BF75A1 LRTA, BF75A1 XRTA, BF75A2 LHTA, BF75A2 LRTA, BF75A2 XRTA, BF75A3 LHTA, BF75A3 LRTA, BF75A3 XRTA, BF75A4 LHTA, BF75A4 LRTA, BF75A4 XRTA, BF75A5 LHTA, BF75A5 LRTA, BF75A5 XRTA, BF75A6 LHTA, BF75A6 LRTA, BF75A6 XRTA, BF75AX LHTA, BF7
91054-ZW1-B31
BEARING, TAPER ROLLER (Honda Code 6994420). (30X62X40)
91054-ZW1-B31 BEARING, TAPER ROLLER (Honda Code 6994420). (30X62X40)
BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA, BF115A6 LA, BF115A6 LCA, BF115A6 XA, BF115A6 XCA,
13211-PWA-003
BEARING A, CONNECTING ROD (BLUE) (DAIDO)
13211-PWA-003 BEARING A, CONNECTING ROD (BLUE) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
13212-PWA-003
BEARING B, CONNECTING ROD (BLACK) (DAIDO)
13212-PWA-003 BEARING B, CONNECTING ROD (BLACK) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
13214-PWA-003
BEARING D, CONNECTING ROD (GREEN) (DAIDO)
13214-PWA-003 BEARING D, CONNECTING ROD (GREEN) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
13343-PWA-003
BEARING C, MAIN (LOWER) (BROWN) (DAIDO)
13343-PWA-003 BEARING C, MAIN (LOWER) (BROWN) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
13344-PWA-003
BEARING D, MAIN (LOWER) (GREEN) (DAIDO)
13344-PWA-003 BEARING D, MAIN (LOWER) (GREEN) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
13345-PWA-003
BEARING E, MAIN (LOWER) (YELLOW) (DAIDO)
13345-PWA-003 BEARING E, MAIN (LOWER) (YELLOW) (DAIDO)
BF60AK1 LRTA, BF60AK1 XRTA, BF75DK0 LHTA, BF75DK0 LRTA, BF75DK2 LRTA, BF90DK0 LHTA, BF90DK0 LRTA, BF90DK0 XRTA, BF90DK2 LRTA, BF90DK2 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
Back to top