90125-ZZ3-650 BOLT, STUD (10X154) Honda
BF60AK1 XRTA
BOLT
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
BF60AK1 XRTA
Honda
Honda entire parts catalog list:
Information:
Instrument Panel
Wiring Diagram For Instrument Panel
(1) Light switch. (2) Panel lights. (3) Instrument panel. (4) Ammeter. (5) Oil pressure gauge. (6) Water temperature gauge. (7) Gear oil pressure gauge. (8) Terminal strip. (9) Wire to battery. (10) Oil pressure switch with time delay. (11) Sending unit for oil pressure. (12) Sending unit for water temperature. (13) Sending unit for gear oil pressure.
Gauges With Resistors For 32 Volt System
(1) Resistor. (2) Oil pressure gauge. (3) Resistor. (4) Water temperature gauge. (5) Resistor. (6) Gear oil pressure gauge.
Resistor For 32 Volt System (65Ohms)Indicators And Sending Units
Sending Unit for Water Temperature
Sending Unit For Water Temperature
(1) Connection. (2) Bushing. (3) Bulb.The sending unit for water temperature is an electrical resistance. It changes the value of its resistance according to the temperature which the bulb (3) feels.The sending unit is in a series circuit with the electrical indicator. When the temperature is high, the resistance is high. This makes the indicator have a high reading.The sending unit must be in contact with the coolant. If the coolant level is too low because of a sudden loss of coolant while the engine is running or because the level is too low before starting the engine, the sending unit will not work correctly.Sending Unit for Oil Pressure
Sending Unit For Oil Pressure
(1) Connection. (2) Bushing.The sending unit for oil pressure is an electrical resistance. It has a material which changes electrical resistance according to pressure which it feels.The sending unit for oil pressure is in a series circuit with the electrical indicator. As the pressure on the sending unit changes, the reading on the indicator changes in the same way.Electric Hour Meter
Hour Meter Wiring Diagram
(1) Electrical hour meter. (2) Pressure switch. (3) To alternator or battery.Electric hour meter (1) measures the clock hours that the engine operates. The hour meter activates when pressure switch (2) closes. Pressure switch (2) closes the circuit from the positive terminal on the alternator or battery when the engine oil pressure is above approximately 6 psi (40 kPa).Electric Tachometer Wiring
(1) Magnetic pickup. (2) Terminal connections - terminals 7 and 8 on standby governor control. (3) Tachometer. (4) Ground connection - governor control chassis ground. (5) Governor control terminal strip. (6) Wiring connections - for second tachometer circuit. (7) All wire must be 22AWG shielded cable or larger. (8) Dual speed switch terminal strip. (9) Ground connection - ground to engine.Wiring Diagram
Starting And Charging System
(1) Off, start switch. (2) Ammeter. (3) Fuel shutoff solenoid. (4) Starter solenoid. (5) Alternator regulator. (6) Starter motor. (7) Pressure switch - normally open. (8) Alternator. (9) Battery. (10) Hourmeter. Automatic Start/Stop System
Automatic Start/Stop System Schematic (Hydraulic Governor)
(1) Starter motor and solenoid). (2) Shutoff solenoid. (3) Fuel pressure switch. (4) Water temperature switch. (5) Oil pressure switch. (6) Overspeed contactor. (7) Battery. (8) Low lubricating oil pressure light (OPL). (9) Overcrank light (OCL). (10) Overspeed light (OSL). (11) High water temperature light (WTL). (12) Automatic control switch (ACS).An automatic start/stop system is used when a standby electric set has to give power to a system if the normal (commercial) power supply has a failure. There are three main sections in the system. They are: the automatic transfer switch, the start/stop control panel (part of switch gear) and the electric set.Automatic Transfer Switch
Automatic Transfer Switch (Typical Illustration)The automatic transfer switch normally connects the 3-phase normal (commercial) power supply to the load. When the commercial power supply has a failure the switch will transfer the load to the standby electric set. The transfer switch will not transfer the load from commercial to emergency power until the emergency power gets to the rated voltage and frequency. The reason for this is, the solenoid that causes the transfer of power operates on the voltage from the standby electric set. When the normal power returns to the rated voltage and frequency and the time delay (if so equipped) is over, the transfer switch will return the load to the normal power supply.Control Panel (Later)
Electronic Modular Control Panel (EMCP II)
(1) Optional panel lights. (2) Optional governor switch (shown) or speed potentionmeter. (3) Optional starting aid switch. (4) Engine control switch. (5) Optional alarm module (shown) or synchronizing lights module. (6) Voltage adjust rheostat. (7) Emergency stop push button. (8) Generator set control. (9) Optional panel light switch.The main function of the control panel is to control the start and shutoff of the engine.The engine control on the automatic start/stop control panel is an automatic engine control switch (ECS) with four positions. The positions of the engine control switch (4) are: OFF/RESET, AUTO, MAN./START, and COOLDOWN/STOP. Each light goes ON only when an abnormal condition in the engine stops the engine. The light for the condition in the engine that stopped the engine is ON even after the engine has stopped. Engine control switch (4) must be moved to the OFF/RESET position for the light to go OFF. Each light will go ON, for a light test, when the light is pushed in and held.When the generator is to be used as a standby electric power unit, the automatic control switch is put in the AUTO position. Now, if the normal (commercial) electric power stops, the engine starts and the generator takes the electric load automatically. When the normal (commercial) electric power is ON again, or the electric load, the transfer switch opens its contacts to the generator, and closes its contacts to the normal (commercial) electric power. After the transfer switch for the generator opens, the engine automatically stops, usually after running for a cooldown time.When the automatic engine control switch (ECS) is moved to the MAN./START position, the engine starts. It may now be necessary for the circuit breaker for the generator electric power to be closed manually to the load. If the generator is a standby electric power unit and the automatic engine control switch (ECS) is in the MAN./START position when normal (commercial) electric power stops, the automatic engine control switch (ECS) can be put into the AUTO position and
Wiring Diagram For Instrument Panel
(1) Light switch. (2) Panel lights. (3) Instrument panel. (4) Ammeter. (5) Oil pressure gauge. (6) Water temperature gauge. (7) Gear oil pressure gauge. (8) Terminal strip. (9) Wire to battery. (10) Oil pressure switch with time delay. (11) Sending unit for oil pressure. (12) Sending unit for water temperature. (13) Sending unit for gear oil pressure.
Gauges With Resistors For 32 Volt System
(1) Resistor. (2) Oil pressure gauge. (3) Resistor. (4) Water temperature gauge. (5) Resistor. (6) Gear oil pressure gauge.
Resistor For 32 Volt System (65Ohms)Indicators And Sending Units
Sending Unit for Water Temperature
Sending Unit For Water Temperature
(1) Connection. (2) Bushing. (3) Bulb.The sending unit for water temperature is an electrical resistance. It changes the value of its resistance according to the temperature which the bulb (3) feels.The sending unit is in a series circuit with the electrical indicator. When the temperature is high, the resistance is high. This makes the indicator have a high reading.The sending unit must be in contact with the coolant. If the coolant level is too low because of a sudden loss of coolant while the engine is running or because the level is too low before starting the engine, the sending unit will not work correctly.Sending Unit for Oil Pressure
Sending Unit For Oil Pressure
(1) Connection. (2) Bushing.The sending unit for oil pressure is an electrical resistance. It has a material which changes electrical resistance according to pressure which it feels.The sending unit for oil pressure is in a series circuit with the electrical indicator. As the pressure on the sending unit changes, the reading on the indicator changes in the same way.Electric Hour Meter
Hour Meter Wiring Diagram
(1) Electrical hour meter. (2) Pressure switch. (3) To alternator or battery.Electric hour meter (1) measures the clock hours that the engine operates. The hour meter activates when pressure switch (2) closes. Pressure switch (2) closes the circuit from the positive terminal on the alternator or battery when the engine oil pressure is above approximately 6 psi (40 kPa).Electric Tachometer Wiring
(1) Magnetic pickup. (2) Terminal connections - terminals 7 and 8 on standby governor control. (3) Tachometer. (4) Ground connection - governor control chassis ground. (5) Governor control terminal strip. (6) Wiring connections - for second tachometer circuit. (7) All wire must be 22AWG shielded cable or larger. (8) Dual speed switch terminal strip. (9) Ground connection - ground to engine.Wiring Diagram
Starting And Charging System
(1) Off, start switch. (2) Ammeter. (3) Fuel shutoff solenoid. (4) Starter solenoid. (5) Alternator regulator. (6) Starter motor. (7) Pressure switch - normally open. (8) Alternator. (9) Battery. (10) Hourmeter. Automatic Start/Stop System
Automatic Start/Stop System Schematic (Hydraulic Governor)
(1) Starter motor and solenoid). (2) Shutoff solenoid. (3) Fuel pressure switch. (4) Water temperature switch. (5) Oil pressure switch. (6) Overspeed contactor. (7) Battery. (8) Low lubricating oil pressure light (OPL). (9) Overcrank light (OCL). (10) Overspeed light (OSL). (11) High water temperature light (WTL). (12) Automatic control switch (ACS).An automatic start/stop system is used when a standby electric set has to give power to a system if the normal (commercial) power supply has a failure. There are three main sections in the system. They are: the automatic transfer switch, the start/stop control panel (part of switch gear) and the electric set.Automatic Transfer Switch
Automatic Transfer Switch (Typical Illustration)The automatic transfer switch normally connects the 3-phase normal (commercial) power supply to the load. When the commercial power supply has a failure the switch will transfer the load to the standby electric set. The transfer switch will not transfer the load from commercial to emergency power until the emergency power gets to the rated voltage and frequency. The reason for this is, the solenoid that causes the transfer of power operates on the voltage from the standby electric set. When the normal power returns to the rated voltage and frequency and the time delay (if so equipped) is over, the transfer switch will return the load to the normal power supply.Control Panel (Later)
Electronic Modular Control Panel (EMCP II)
(1) Optional panel lights. (2) Optional governor switch (shown) or speed potentionmeter. (3) Optional starting aid switch. (4) Engine control switch. (5) Optional alarm module (shown) or synchronizing lights module. (6) Voltage adjust rheostat. (7) Emergency stop push button. (8) Generator set control. (9) Optional panel light switch.The main function of the control panel is to control the start and shutoff of the engine.The engine control on the automatic start/stop control panel is an automatic engine control switch (ECS) with four positions. The positions of the engine control switch (4) are: OFF/RESET, AUTO, MAN./START, and COOLDOWN/STOP. Each light goes ON only when an abnormal condition in the engine stops the engine. The light for the condition in the engine that stopped the engine is ON even after the engine has stopped. Engine control switch (4) must be moved to the OFF/RESET position for the light to go OFF. Each light will go ON, for a light test, when the light is pushed in and held.When the generator is to be used as a standby electric power unit, the automatic control switch is put in the AUTO position. Now, if the normal (commercial) electric power stops, the engine starts and the generator takes the electric load automatically. When the normal (commercial) electric power is ON again, or the electric load, the transfer switch opens its contacts to the generator, and closes its contacts to the normal (commercial) electric power. After the transfer switch for the generator opens, the engine automatically stops, usually after running for a cooldown time.When the automatic engine control switch (ECS) is moved to the MAN./START position, the engine starts. It may now be necessary for the circuit breaker for the generator electric power to be closed manually to the load. If the generator is a standby electric power unit and the automatic engine control switch (ECS) is in the MAN./START position when normal (commercial) electric power stops, the automatic engine control switch (ECS) can be put into the AUTO position and
Parts bolt Honda:
92101-05016-4J
92101-05016-4J BOLT, HEX. (5X16) (Honda Code 3706959).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
90014-ZW9-000
90014-ZW9-000 BOLT, FLANGE (6X10) (Honda Code 6643852).
BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF150A4 LA, BF150A4 XA, BF150A4 XCA, BF150A5 LA, BF150A5 XA, BF150A5 XCA, BF150A6 LA, BF150A6 XA, B
90008-ZW9-000
90008-ZW9-000 BOLT, FLANGE (8X35) (Honda Code 6643795).
BF115A4 LA, BF115A4 XA, BF115A6 LA, BF115A6 XA, BF115AK0 LA, BF115AK0 XA, BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA,
90158-ZW4-000
90158-ZW4-000 BOLT, FLANGE (8X70) (Honda Code 7226673).
BF60AK1 LRTA, BF60AK1 XRTA, BF75A2 LHTA, BF75A2 LRTA, BF75A2 XRTA, BF75A3 LHTA, BF75A3 LRTA, BF75A3 XRTA, BF75A4 LHTA, BF75A4 LRTA, BF75A4 XRTA, BF75A5 LHTA, BF75A5 LRTA, BF75A5 XRTA, BF75A6 LHTA, BF75A6 LRTA, BF75A6 XRTA, BF90A2 JHTA, BF90A2 JRTA, B
90009-PP4-E01
90009-PP4-E01 BOLT, SEALING (6MM) (Honda Code 3897873).
BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA, BF115A6 LA, BF115A6 LCA, BF115A6 XA, BF115A6 XCA,
90111-ZW4-H11
90111-ZW4-H11 BOLT, SOCKET (5X0.8) (Honda Code 7558539).
BF25D4 LHTA, BF25D4 LRTA, BF25D4 SRTA, BF25D5 LHTA, BF25D5 LRTA, BF25D5 SRTA, BF25D6 LHTA, BF25D6 LRTA, BF25D6 SRTA, BF25DK0 LRTA, BF25DK2 LRTA, BF25DK3 LRTA, BF30D4 LHTA, BF30D4 LRTA, BF30D4 SRTA, BF30D5 LHTA, BF30D5 LRTA, BF30D5 SRTA, BF30D6 LHTA,
12109-ZZ3-000
12109-ZZ3-000 BOLT, BLOCK OIL DRAIN
BF60AK1 LRTA, BF60AK1 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA
90002-ZZ3-000
90002-ZZ3-000 BOLT, FLANGE (8X60) (SUS)
BF60AK1 LRTA, BF60AK1 XRTA, BFP60AK1 LRTA, BFP60AK1 LRTB, BFP60AK1 XRTA