19289-ZY6-000 Honda CAP, WATER JOINT


19289-ZY6-000 CAP, WATER JOINT Honda BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4 CAP
19289-ZY6-000 CAP, WATER JOINT Honda
Rating:
48

Buy CAP, WATER JOINT 19289-ZY6-000 Honda genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Honda entire parts catalog list:

BF115DK1 LA 2007
BF115DK1 XA 2007
BF115DK1 XCA 2007
BF135A4 LA 2004
BF135A4 XA 2004
BF135A4 XCA 2004
BF135A5 LA 2005
BF135A5 XA 2005
BF135A5 XCA 2005
BF135A6 LA 2006
BF135A6 XA 2006
BF135A6 XCA 2006
BF135AK0 LA 2007
BF135AK0 XA 2007
BF135AK0 XCA 2007
BF135AK2 LA 2007
BF135AK2 XA 2007
BF135AK2 XCA 2007
BF150A4 LA 2004
BF150A4 XA 2004
BF150A4 XCA 2004
BF150A5 LA 2005
BF150A5 XA 2005
BF150A5 XCA 2005
BF150A6 LA 2006
BF150A6 XA 2006
BF150A6 XCA 2006
BF150AK0 LA 2007
BF150AK0 XA 2007
BF150AK0 XCA 2007
BF150AK2 LA 2007
BF150AK2 XA 2007
BF150AK2 XCA 2007
BF60AK1 LRTA 2007
BF60AK1 XRTA 2007
BF75DK0 LHTA 2007
BF75DK0 LRTA 2007
BF75DK2 LRTA 2007
BF90DK0 LHTA 2007
BF90DK0 LRTA 2007
BF90DK0 XRTA 2007
BF90DK2 LRTA 2007
BF90DK2 XRTA 2007
BFP60AK1 LRTA 2007
BFP60AK1 LRTB 2007
BFP60AK1 XRTA 2007

Information:

General Troubleshooting And Repair Of The Engine Horsepower Meter And Accessories
General Troubleshooting Procedure
The following section gives a general procedure for isolating a faulty portion of the entire Engine Horsepower Meter Arrangement. It is written to enable a person with reasonable knowledge of electricity and a multimeter to find simple faults which are field repairable, without taking the unit to an electronics repair facility or returning it to the manufacturer.If the following procedure does not isolate the problem, U.S. dealers should return the unit (Horsepower Meter or flowmeter only) to the appropriate address shown on page 49. Dealers outside the U.S. may wish to have the unit further inspected and repaired locally by a qualified electronics shop which is familiar with digital circuitry.The material on pages 20-23 and pages 26-48 is intended only for those situations where it is not practical to return the unit to the U.S. for repair. U.S. dealers are urged to send their units to Fluidyne Instrumentation where repairs and calibration can be performed more precisely and efficiently. Be sure to check out the components by using the following procedure in the order indicated. Do not omit any tests unless the unit is known to operate correctly in that specific mode.
Do not use a continuity light to trace circuits on either printed circuit board. Some semiconductor components can be damaged if 3 volts is connected across them.
1. Turn the POWER switch to ON (Be sure the knob has not slipped on the shaft).2. Do any of the display lights light? a) YES - Go to Step 3.b) NO - Open the Horsepower Meter and perform the steps shown on page 6. If the problem cannot be identified as a blown fuse, bad switch contact, broken wire, loose battery connection, dead batteries, etc., return the unit to Fluidyne Instrumentation (see page 49). If the problem is known to be in the power board, return only the power board to Fluidyne.3. Are the display lights dim? a) NO - Go to Step 4.b) YES - Check for a voltage at the batteries of greater than 5.2 volts. If the voltage is less, recharge the batteries to over 6 volts and recheck. (If the batteries won't charge, go to Step 15.) Check for voltage losses between the batteries and wiring point 16 and the displays. The voltage should be greater than 5 volts at wiring point 16.4. Do any of the lights have the correct brilliance? a) YES - Go to Step 5.b) NO - Review Step 2. If the problem cannot be found, return the unit to Fluidyne.5. If all digits light correctly, go to Step 6. Individual lamps or related 7447's (integrated circuits) may fail while most digits work properly. Interchange known good components with suspected components. See page 24. Be sure to remove the plug-in lights carefully so they separate correctly from their sockets. Replacement lamps and 7447's are available from Fluidyne. If any soldered component is suspected, return the entire unit to Fluidyne.6. With the POWER switch ON, turn the MODE switch to the BATT. TEST position (be sure the knob has not slipped on the shaft). Is the displayed value greater than 5.0 volts? a) YES - The power supply circuit and displays are basically operational. Go to Step 7.b) NO - Review Step 2. If the problem cannot be found, return the unit to Fluidyne.7. If the BATT. TEST value is less than 5.80 volts, recharge the batteries so there is sufficient power to complete the remaining tests. If the batteries cannot be charged, Step 15.8. Turn the MODE switch to the ENGINE SPEED VERIFY position. Is 6000 rpm displayed? a) YES - The tachometer circuit in the Horsepower Meter is operational. Go to Step 9.b) NO - Is only one digit wrong? (1) YES - See step 5.(2) NO - Check for broken wires, a broken switch, etc. If no physical defects can be seen, an oscilliscope is needed for more testing. Return the unit to Fluidyne. A tachometer circuit defect will not affect the flow rate readings or horsepower tests.9. Connect the Tachometer Generator and RPM cable to the Horsepower Meter. Turn the MODE switch to any position except ENGINE SPEED VERIFY. Spin the generator shaft by hand. Is a fluctuating reading displayed (approximately 300 - 500 rpm)? a) YES - All tachometer components are basically operational. If difficulty is encountered while running on an engine, check the tachometer generator and adjustment (see the NOTE below and page 8). Be sure to install the generator only finger-tight and check that the tachometer drive ratio is correct (shaft running at 1/2 engine speed). Electrical noise (from older electric sets) can be eliminated by using a shielded 9S3048 Cable Assembly between the tachometer generator and the 5P2159 Cable. If the tachometer circuit is correct while running an engine, go to Step 10.b) NO - Check the rpm cable for continuity and for shorts, and the tachometer generator (see page 13). If the generator and cable check is satisfactory, look for obvious physical defects in the readout box. If none can be seen, return the unit to Fluidyne. Pin A of the threaded connector of the rpm cable should be connected to the center terminal of the phone jack on the opposite end. Some cables may be assembled wrong.10. Turn the MODE switch to the GAL/HR CALIB. position. If the unit has been turned on for at least 5 minutes, is the GAL/HR CALIB. value (top display) stable and within the tolerance given on the lid of the unit? a) YES - The gallons per hour circuitry is basically operational. Go to Step 11.b) NO - If the value is within 1.0 gph, the unit may simply need to be calibrated. See pages 9 - 12. Special electronic equipment is needed for calibration (see page 11), so it is suggested that the unit be returned to Fluidyne for correct calibration. It is also possible that the Digital-to-Analog Converter (DAC) is malfunctioning.


Parts cap Honda:

15611-921-000
CAP, OIL (Honda Code 0282806).
15611-921-000 CAP, OIL (Honda Code 0282806).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
50331-ZV5-000
CAP, TILTING BOLT (Honda Code 3704921).
50331-ZV5-000 CAP, TILTING BOLT (Honda Code 3704921).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
56860-ZW1-701
CAP, OIL TANK (Honda Code 4900304).
56860-ZW1-701 CAP, OIL TANK (Honda Code 4900304).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
24814-ZW5-U01
CAP, GRIP (Honda Code 6799589).
24814-ZW5-U01 CAP, GRIP (Honda Code 6799589).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
24815-ZW5-U01
CAP, SWITCH (Honda Code 6799605).
24815-ZW5-U01 CAP, SWITCH (Honda Code 6799605).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
63515-ZC0-700
CAP, L. SIDE COVER (Honda Code 5893078).
63515-ZC0-700 CAP, L. SIDE COVER (Honda Code 5893078).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
90082-ZY6-003
 
90082-ZY6-003 CAP, BOLT (8MM) (Honda Code 7636236).
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4
16744-ZY6-000
 
16744-ZY6-000 CAP, REGULATOR (Honda Code 7633803).
BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF150A4 LA, BF150A4 XA, BF150A4 XCA, BF150A5 LA, BF150A5 XA, BF150A5 XCA
Back to top