90311-GK8-000 Honda COLLAR (6MM) (Honda Code 1709963).


90311-GK8-000 COLLAR (6MM) (Honda Code 1709963). Honda BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115AX LA, BF115AX LCA, BF115AX XA, BF115AX XCA, BF115AY LA, BF115AY LCA, BF115AY XA, BF115AY XCA, BF130A1 LA, BF130A1 LCA, BF130A1 XA, BF130A1 XCA, COLLAR
90311-GK8-000 COLLAR (6MM) (Honda Code 1709963). Honda
Rating:
88

Buy COLLAR (6MM) (Honda Code 1709963). 90311-GK8-000 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$11.97
 

21-01-2024
0.25[0.11] pounds
US: PowerToolReplacement
Honda 90311-GK8-000 Collar (6MM)
Honda Honda 90311-GK8-000 Collar (6MM)
Number on catalog scheme: 26
 

Honda entire parts catalog list:

BF115A1 LA 2001
BF115A1 LCA 2001
BF115A1 XA 2001
BF115A1 XCA 2001
BF115A2 LA 2002
BF115A2 LCA 2002
BF115A2 XA 2002
BF115A2 XCA 2002
BF115AX LA 1999
BF115AX LCA 1999
BF115AX XA 1999
BF115AX XCA 1999
BF115AY LA 2000
BF115AY LCA 2000
BF115AY XA 2000
BF115AY XCA 2000
BF130A1 LA 2001
BF130A1 LCA 2001
BF130A1 XA 2001
BF130A1 XCA 2001
BF130A2 LA 2002
BF130A2 LCA 2002
BF130A2 XA 2002
BF130A2 XCA 2002
BF130AX LA 1999
BF130AX LCA 1999
BF130AX XA 1999
BF130AX XCA 1999
BF130AY LA 2000
BF130AY LCA 2000
BF130AY XA 2000
BF130AY XCA 2000

Information:


Personal injury or death can result from improper troubleshooting and repair procedures.The following troubleshooting and repair procedures should only be performed by qualified personnel familiar with this equipment.
If the generator is not placed into operation immediately, the generator must be protected against moisture, dirt, and high temperatures. The protection of the generator will avoid undesirable problems with the insulation integrity and resistance.The resistance of the insulation of the windings must be measured before the generator is put into operation.If the environment for generator storage is humid, the resistance of the insulation of the windings must be measured periodically during storage. There is difficultly in determining the appropriate values of insulation resistance of a generator. The reading will vary with environmental conditions such as temperature and humidity. Dust, oil, grease, and dirt will affect the condition of generator insulation resistance as well as the quality and condition of the insulating material used. Periodic monitoring records are useful to conclude whether the motor is able to operate.Note: The insulation resistance must be measured using a megohm meter.Preparation for Insulation Testing
Verify that the generator frame is grounded to earth via a low impedance path that is less than 25 ohms.
Install a barrier around the work area to limit access to only the qualified personnel essential to conducting the test.
Perform the following steps before making test instrument connections and measuring the resistance of the insulation for windings:
Ensure that the generator has stopped
Ensure that all sources of power are switched off and that the unit is electrically isolated
Ensure that the generator is de-energized
Ensure that the generator is disconnected from the load
Use proper methods to prohibit the windings from becoming energized while making connections and conducting tests.
Use safe work practices to discharge the generator windings. Discharging is accomplished by connecting the winding to the generator frame. Verify that the winding to be tested has been discharged.
Isolate the windings that are to be tested from the remainder of the generator set. Isolating the windings includes disconnecting necessary components such as the following:
Voltage regulator
EMCP
Neutral to ground bonding conductor (if equipped)
The load share module (if equipped)
Power transformers (if equipped)
Temperature of the winding has been measured
All temperature sensors are groundedNote: Make sure that all windings that are not being tested, are appropriately grounded to the generator frame. For example, if a winding in the main stator is to be checked, then all of the following must be grounded to the generator stator frame:
Main rotor
Exciter rotor
Exciter stator
Auxiliary winding
Other componentsTherefore, only the main stator winding that is being tested should NOT be grounded.
Test the winding insulation.
Ensure that there is no residual power in the windings. Immediately following testing, the winding must be discharged manually or automatically with the test instrument.
Repeat Step 8 for each winding.
The generator can be reassembled after all of the windings have been tested and discharged.
Restore the unit to normal operating condition and remove the barrier.Measurement of the Stator Windings
The test voltage used for the stator windings of the generator must be what is shown in Table 1. The voltages used are in accordance with Standard IEEE43.
Table 1
Winding nominal voltage (V)    Insulation resistance test voltage (V)    
Less than 1000     500    
1000 - 2500     500 -1000    
2501 - 5000     1000 - 2500    
5001 - 12000     2500 - 5000    
Greater than 12000     5000 - 10000    The measurement of the insulation resistance of the stator windings must be made in the main terminal box. The meter (megohm meter) must be connected between the frame of the alternator and the winding. The frame must be grounded and all three phases of the stator winding must remain connected to the neutral point. Refer to Illustration 1.
Illustration 1 g03774134
Measuring all three phases (1) Generator frame (2) Stator windings (3) Megohm meter (4) Neutral connectionWhenever possible, each phase must be insulated and tested separately. The separate test allows the comparison between the phases. When a phase is tested, the other two phases must be tied to the same ground point of the frame. Refer to Illustration 2.
Illustration 2 g03774165
Measuring individual phases (6) Generator frame (7) Stator winding being tested (8) Megohm meter (9) Grounded windings (10) Neutral connectionResistance Check for Rotor, Exciter, and Accessories
Measurement of the Main Rotor Winding
Use the following steps to measure the rotor windings.
Illustration 3 g03774475
(15) Exciter stator (16) Exciter rotor (17) Diode connections (18) Diodes
Illustration 4 g03774508
(19) Rotor cables to be disconnected
Disconnect the rotor cables (19) from the set of diodes (18) on the exciter rotor (16) .
Connect the megohm meter between the rotor winding and the shaft of the alternator.Note:


Parts collar Honda:

53109-ZV0-000
 
53109-ZV0-000 COLLAR, DISTANCE (Honda Code 1815802).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
91551-ZV4-000
 
91551-ZV4-000 COLLAR, DISTANCE (6MM) (Honda Code 2801116).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
91563-ZV5-000
 
91563-ZV5-000 COLLAR, DISTANCE (6X10.5X25) (Honda Code 3706900).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
24854-ZV5-000
COLLAR, SLIDING PLATE (Honda Code 3703196).
24854-ZV5-000 COLLAR, SLIDING PLATE (Honda Code 3703196).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
91560-ZV5-000
COLLAR, STEERING ROD (Honda Code 3706892).
91560-ZV5-000 COLLAR, STEERING ROD (Honda Code 3706892).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
14635-ZW5-000
COLLAR, ROCKER (A) (Honda Code 5890686).
14635-ZW5-000 COLLAR, ROCKER (A) (Honda Code 5890686).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
14636-ZW5-000
 
14636-ZW5-000 COLLAR, ROCKER (B) (Honda Code 5890694).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
14651-PAB-A00
COLLAR A, IN. ROCKER (Honda Code 5612759).
14651-PAB-A00 COLLAR A, IN. ROCKER (Honda Code 5612759).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
Back to top