32414-ZY6-640 COVER B, TERMINAL Honda
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150AK0 LA, BF150AK0 XA, BF150AK0 XCA, BF150AK2 LA, BF150AK2 XA, BF150AK2 XCA, BF250A LA, BF250A XA, BF250A XCA, BF250A XXA, BF25
COVER
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
Honda entire parts catalog list:
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE (2) » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
- STARTER CABLE » 32414-ZY6-640
Information:
Illustration 1 g01107274
Illustration 2 g01107279When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Minimum speed with no load ... 3300 rpmMaximum current with no load ... 80 ampVoltage ... 23.5 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 1.5 0.5 N m (13 4 lb in) (3) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 17.5 2.5 N m (155 22 lb in)Current draw at 24 V and 25 °C (77 °F)Pull-in windings ... 103 AmpHold-in windings ... 19 Amp maximum 6V-5537 Electric Starting Motor Gp and 6V-5207 Electric Starting Motor Gp
Illustration 3 g01107221
Illustration 4 g01107223When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F)Speed ... 7643 1683 rpmCurrent draw ... 67.5 7.5 ampVoltage ... 23 VNote: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (1) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (2) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 8 3 N m (70 27 lb in)Clearance between the pinion and the housing ... 9.1 mm (0.36 inch) 6V-5023 Electric Starting Motor Gp
Illustration 5 g01107286
Illustration 6 g01107308When the electric starting motor is viewed from the drive end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 5500 rpm minimumCurrent draw ... 140 amp maximumVoltage ... 24 V (1) Torque for the ground terminal nut ... 30.5 3.5 N m (270 30 lb in)Note: A maximum of three cable or wire terminals should be between the nuts. A maximum of two of the terminals may be equal to or greater than 0 AWG. (2) Torque for the battery terminal nut ... 30.5 3.5 N m (270 30 lb in) (3) Torque for the ground terminal nut ... 2.25 0.25 N m (20 2 lb in)Note: The wire terminal that is on the switch terminal must be insulated with heat shrink tubing. Do not use molded terminals. (4) Torque for the switch terminal nut ... 2.25 0.25 N m (20 2 lb in) (5) Torque for the motor terminal nut ... 30.5 3.5 N m (270 30 lb in) (6) Torque for the motor frame terminal nut ... 30.5 3.5 N m (270 30 lb in) 9X-0332 Solenoid KitCurrent consumption at 25 °C (77 °F) Pull-in windings at 24 V ... 51 ampHold-in windings at 24 V ... 7 amp
Parts cover Honda:
24812-ZW7-U01
24812-ZW7-U01 COVER, GRIP (Honda Code 6799548).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
24814-ZW7-U01
24814-ZW7-U01 COVER, LOCK ARM (Honda Code 6799597).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
24812-ZW5-U01
24812-ZW5-U01 COVER, L. GRIP (Honda Code 6799522).
BF115A1 LA, BF115A1 LCA, BF115A1 XA, BF115A1 XCA, BF115A2 LA, BF115A2 LCA, BF115A2 XA, BF115A2 XCA, BF115A3 LA, BF115A3 LCA, BF115A3 XA, BF115A3 XCA, BF115A4 LA, BF115A4 LCA, BF115A4 XA, BF115A4 XCA, BF115A5 LA, BF115A5 LCA, BF115A5 XA, BF115A5 XCA,
19315-ZY6-000
19315-ZY6-000 COVER, THERMOSTAT (Honda Code 7634389).
BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF150A4 LA, BF150A4 XA, BF150A4 XCA, BF150A5 LA, BF150A5 XA, BF150A5 XCA, BF150A6 LA, BF150A6 XA, B
19315-ZY6-010
19315-ZY6-010 COVER, THERMOSTAT (Honda Code 8951543).
BF115DK1 LA, BF115DK1 XA, BF115DK1 XCA, BF135A4 LA, BF135A4 XA, BF135A4 XCA, BF135A5 LA, BF135A5 XA, BF135A5 XCA, BF135A6 LA, BF135A6 XA, BF135A6 XCA, BF135AK0 LA, BF135AK0 XA, BF135AK0 XCA, BF135AK2 LA, BF135AK2 XA, BF135AK2 XCA, BF150A4 LA, BF150A4
15656-ZY3-000
15656-ZY3-000 COVER, OIL LEVEL GAUGE
BF175AK1 LA, BF175AK1 XA, BF175AK1 XCA, BF175AK2 LA, BF175AK2 XA, BF175AK2 XCA, BF200AK0 LA, BF200AK0 XA, BF200AK0 XCA, BF200AK1 LA, BF200AK1 XA, BF200AK1 XCA, BF200AK2 LA, BF200AK2 XA, BF200AK2 XCA, BF225AK0 LA, BF225AK0 XA, BF225AK0 XCA, BF225AK0 X
63347-ZY3-C00
63347-ZY3-C00 COVER, PLUG MAINTENANCE
BF175AK1 LA, BF175AK1 XA, BF175AK2 LA, BF175AK2 XA, BF175AK2 XCA, BF200AK1 LA, BF200AK1 XA, BF200AK1 XCA, BF200AK2 LA, BF200AK2 XA, BF200AK2 XCA, BF225AK1 LA, BF225AK1 XA, BF225AK1 XCA, BF225AK1 XXA, BF225AK1 XXCA, BF225AK2 LA, BF225AK2 XA, BF225AK2
32414-ZX2-300