12215-ZW4-000 Honda CYLINDER HEAD ASSY. *NH8* (Honda Code 6375554). (DARK GRAY)


12215-ZW4-000 CYLINDER HEAD ASSY. *NH8* (Honda Code 6375554). (DARK GRAY) Honda BF50A1 LHTA, BF50A1 LRA, BF50A1 LRTA, BF50A1 SRJA, BF50A1 XRTA, BF50A2 LHTA, BF50A2 LRA, BF50A2 LRTA, BF50A2 SRJA, BF50A2 XRTA, BF50A3 LHTA, BF50A3 LRA, BF50A3 LRTA, BF50A3 SRJA, BF50A3 XRTA, BF50AW LHTA, BF50AW LRA, BF50AW LRTA, BF50AW SRJA, BF50AW CYLINDER

Buy CYLINDER HEAD ASSY. *NH8* (Honda Code 6375554). (DARK GRAY) 12215-ZW4-000 Honda genuine, new aftermarket parts with delivery
Number on catalog scheme: 1
 

Honda entire parts catalog list:

BF50A1 LHTA 2001
BF50A1 LRA 2001
BF50A1 LRTA 2001
BF50A1 SRJA 2001
BF50A1 XRTA 2001
BF50A2 LHTA 2002
BF50A2 LRA 2002
BF50A2 LRTA 2002
BF50A2 SRJA 2002
BF50A2 XRTA 2002
BF50A3 LHTA 2003
BF50A3 LRA 2003
BF50A3 LRTA 2003
BF50A3 SRJA 2003
BF50A3 XRTA 2003
BF50AW LHTA 1998
BF50AW LRA 1998
BF50AW LRTA 1998
BF50AW SRJA 1998
BF50AW XRTA 1998
BF50AX LHTA 1999
BF50AX LRA 1999
BF50AX LRTA 1999
BF50AX SRJA 1999
BF50AX XRTA 1999
BF50AY LHTA 2000
BF50AY LRA 2000
BF50AY LRTA 2000
BF50AY SRJA 2000
BF50AY XRTA 2000

Information:


Table 1
J1939 Code and Description CDL Code and Description Comments
3361-8
Aftertreatment #1 DEF Dosing Unit : Abnormal Frequency, Pulse Width, or Period 3102-8
Aftertreatment #1 DEF Dosing Unit : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #1 Diesel Exhaust Fluid Control Unit (DCU) #1 detects an abnormal motor speed signal from the pump.
The code is logged.
4337-8
Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature : Abnormal Frequency, Pulse Width, or Period 3096-8
Aftertreatment 1 Diesel Exhaust Fluid Dosing Temperature : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #1 DCU #1 detects an abnormal temperature signal from the pump.
The code is logged.
4376-7
Aftertreatment 1 Diesel Exhaust Fluid Return Valve : Not Responding Properly 3862-7
Aftertreatment 1 Diesel Exhaust Fluid Return Valve : Not Responding Properly The Aftertreatment #1 DCU #1 detects that the return valve is not responding properly.
The code is logged.
4390-8
Aftertreatment 2 Diesel Exhaust Fluid Doser 1 Temperature : Abnormal Frequency, Pulse Width, or Period 3098-8
Aftertreatment 2 Diesel Exhaust Fluid Doser 1 Temperature : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #2 DCU #1 detects an abnormal temperature signal from the pump.
The code is logged.
4442-7
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 1 Diverter Valve : Not Responding Properly 5009-7
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 1 Diverter Valve : Not Responding Properly The Aftertreatment #2 DCU #1 detects that the return valve is not responding properly.
The code is logged.
4451-8
Aftertreatment #2 DEF Dosing Unit : Abnormal Frequency, Pulse Width, or Period 3109-8
Aftertreatment #2 DEF Dosing Unit : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #2 DCU #1 detects an abnormal motor speed signal from the pump.
The code is logged.
7457-8
Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 2 : Abnormal Frequency, Pulse Width, or Period 5032-8
Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 2 : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #1 DCU #2 detects an abnormal motor speed signal from the pump.
The code is logged.
7460-8
Aftertreatment 1 Diesel Exhaust Fluid Doser 2 Temperature : Abnormal Frequency, Pulse Width, or Period 3097-8
Aftertreatment 1 Diesel Exhaust Fluid Doser 2 Temperature : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #1 DCU #2 detects an abnormal temperature signal from the pump.
The code is logged.
7462-8
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 2 : Abnormal Frequency, Pulse Width, or Period 5033-8
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 2 : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #2 DCU #2 detects an abnormal motor speed signal from the pump.
The code is logged.
7465-8
Aftertreatment 2 Diesel Exhaust Fluid Dosing 2 Temperature : Abnormal Frequency, Pulse Width, or Period 3099-8
Aftertreatment 2 Diesel Exhaust Fluid Dosing 2 Temperature : Abnormal Frequency, Pulse Width, or Period The Aftertreatment #2 DCU #2 detects an abnormal temperature signal from the pump.
The code is logged.
7536-7
Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 2 Diverter Valve : Not Responding Properly 5008-7
Aftertreatment 1 Diesel Exhaust Fluid Dosing Unit 2 Diverter Valve : Not Responding Properly The Aftertreatment #1 DCU #2 detects that the return valve is not responding properly.
The code is logged.
7537-7
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 2 Diverter Valve : Not Responding Properly 5010-7
Aftertreatment 2 Diesel Exhaust Fluid Dosing Unit 2 Diverter Valve : Not Responding Properly The Aftertreatment #2 DCU #2 detects that the return valve is not responding properly.
The code is logged.
Illustration 1 g06300380
(1) Aftertreatment #2 DCU #1
(2) Aftertreatment #2 DCU #2
(3) Aftertreatment #1 DCU #1
(4) Aftertreatment #1 DCU #2Probable Causes
Codes
Connectors and wiring
LeaksRecommended Actions
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot the associated code before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Inspect the Electrical Connectors and the Wiring
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the Diesel Exhaust Fluid (DEF) pump to purge, reset the code, and reset the Diesel Exhaust Fluid Controller Unit (DCU).
B. Disconnect the affected DEF pump electrical connector.
C. Inspect the connector terminals for DEF contamination or corrosion.
Connector and Wiring
Result: The connectors and/or wiring appear to be OK.
Proceed to Test Step 3.
Result: There is a problem with the connectors and/or wiring.
Repair: Replace the Pump Electronic Tank Unit (PETU) connector or wiring. Ensure that all the seals are properly in place and ensure that the connectors are coupled.
Proceed to Test Step 3.
3. Replace the Affected DEF Pump
A. Turn the keyswitch to the OFF position for 2 minutes. The keyswitch must be OFF for 2 minutes to allow the DEF pump to purge, reset the code, and reset the DCU.
B. Replace the appropriate DEF pump. Refer to the Disassembly and Assembly manual for additional information.
C. Turn the keyswitch to the ON position. Do not start the engine.
D. Connect Cat ET.
E. Select the "Selective Catalyst Reduction System".
F. Perform the following diagnostic test to pressurize the system:
-"Aftertreatment Dosing System Functional Test"
G. Visually inspect all DEF lines from the tank to the DEF injectors. Look for pinched, damaged, or disconnected lines.
H. Turn the keyswitch to the OFF position.
Leaks
Result: The lines are not leaking and the test completed successfully.
Return to service.
Result: The test did not complete successfully.
Repair: Perform the following procedure:
1. Repair or replace the damaged components.
2. Connect Cat ET.
3. Select the "Selective Catalyst Reduction System".
4. Perform the following diagnostic test to pressurize the system:
-"Aftertreatment Dosing System Functional Test"
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).


Back to top