31110-ZY3-000ZA Honda FLYWHEEL *TBLACK* (Honda Code 6991434). (BLACK)


31110-ZY3-000ZA FLYWHEEL *TBLACK* (Honda Code 6991434). (BLACK) Honda BF175AK1 LA, BF175AK1 XA, BF175AK1 XCA, BF175AK2 LA, BF175AK2 XA, BF175AK2 XCA, BF200A2 LA, BF200A2 XA, BF200A2 XCA, BF200A2 XXA, BF200A2 XXCA, BF200A3 LA, BF200A3 XA, BF200A3 XCA, BF200A3 XXA, BF200A3 XXCA, BF200A4 LA, BF200A4 XA, BF200A4 XCA, BF200 FLYWHEEL
31110-ZY3-000ZA FLYWHEEL *TBLACK* (Honda Code 6991434). (BLACK) Honda
Rating:
53

Buy FLYWHEEL *TBLACK* (Honda Code 6991434). (BLACK) 31110-ZY3-000ZA Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$482.50
 

19-08-2018
25 Hundredths Pounds
Honda: Honda
Honda 31110-ZY3-000ZA Flywheel *Tblack*
Honda 31110-ZY3-000ZA Flywheel *Tblack*
Number on catalog scheme: 11
 

Honda entire parts catalog list:

BF175AK1 LA 2007
BF175AK1 XA 2007
BF175AK1 XCA 2007
BF175AK2 LA 2007
BF175AK2 XA 2007
BF175AK2 XCA 2007
BF200A2 LA 2002
BF200A2 XA 2002
BF200A2 XCA 2002
BF200A2 XXA 2002
BF200A2 XXCA 2002
BF200A3 LA 2003
BF200A3 XA 2003
BF200A3 XCA 2003
BF200A3 XXA 2003
BF200A3 XXCA 2003
BF200A4 LA 2004
BF200A4 XA 2004
BF200A4 XCA 2004
BF200A4 XXA 2004
BF200A4 XXCA 2004
BF200A5 LA 2005
BF200A5 XA 2005
BF200A5 XCA 2005
BF200A5 XXA 2005
BF200A5 XXCA 2005
BF200A6 LA 2006
BF200A6 XA 2006
BF200A6 XCA 2006
BF200A6 XXA 2006
BF200A6 XXCA 2006
BF200AK0 LA 2007
BF200AK0 XA 2007
BF200AK0 XCA 2007
BF200AK1 LA 2007
BF200AK1 XA 2007
BF200AK1 XCA 2007
BF200AK2 LA 2007
BF200AK2 XA 2007
BF200AK2 XCA 2007
BF225A2 LA 2002
BF225A2 XA 2002
BF225A2 XCA 2002
BF225A2 XXA 2002
BF225A2 XXCA 2002
BF225A3 LA 2003
BF225A3 XA 2003
BF225A3 XCA 2003
BF225A3 XXA 2003
BF225A3 XXCA 2003
BF225A4 LA 2004
BF225A4 XA 2004
BF225A4 XCA 2004
BF225A4 XXA 2004
BF225A4 XXCA 2004
BF225A5 LA 2005
BF225A5 XA 2005
BF225A5 XCA 2005
BF225A5 XXA 2005
BF225A5 XXCA 2005
BF225A6 LA 2006
BF225A6 XA 2006
BF225A6 XCA 2006
BF225A6 XXA 2006
BF225A6 XXCA 2006
BF225AK0 LA 2007
BF225AK0 XA 2007
BF225AK0 XCA 2007
BF225AK0 XXA 2007
BF225AK0 XXCA 2007
BF225AK1 LA 2007
BF225AK1 XA 2007
BF225AK1 XCA 2007
BF225AK1 XXA 2007
BF225AK1 XXCA 2007
BF225AK2 LA 2007
BF225AK2 XA 2007
BF225AK2 XCA 2007
BF225AK2 XXA 2007
BF225AK2 XXCA 2007

Information:


Personal injury or death can result from high voltage.When power generation equipment must be in operation to make tests and/or adjustments, high voltage and current are present.Improper test equipment can fail and present a high voltage shock hazard to its user.Make sure the testing equipment is designed for and correctly operated for high voltage and current tests being made.When servicing or repairing electric power generation equipment:
Make sure the unit is off-line (disconnected from utility and/or other generators power service) , and either locked out or tagged DO NOT OPERATE.
Remove all fuses.
Make sure the generator engine is stopped.
Make sure all batteries are disconnected.
Make sure all capacitors are discharged.Failure to do so could result in personal injury or death. Make sure residual voltage in the rotor, stator and the generator is discharged.
Accidental engine starting can cause injury or death to personnel working on the equipment.To avoid accidental engine starting, disconnect the battery cable from the negative (−) battery terminal. Completely tape all metal surfaces of the disconnected battery cable end in order to prevent contact with other metal surfaces which could activate the engine electrical system.Place a Do Not Operate tag at the Start/Stop switch location to inform personnel that the equipment is being worked on.
Grounding the Frame
In any generator set installation, the frame of the generator must be positively connected to an earth ground. This connection is the first connection that is made at the installation. This connection is the last connection that should be removed. If the generator set is on flexible mounting pads, the ground connection must be flexible to avoid possible breakage in later operation.Ground connection cable or straps should have at least the current carrying capacity of the largest line lead to the connected load. Joints in cables or straps must be clean, free of electrical resistance, and protected from possible oxidation. Bolted ground connection joints eventually oxidize. The joints are frequent sources of radio frequency interference (RFI). Joints that are silver soldered and bolted are preferred.Neutral Connections
The generators with a Wye Configuration usually have the neutral ground when the generator is installed. Grounding the neutral is for preventing damage to equipment.If the neutral wire is grounded and one of the phase leads becomes grounded, the excessive current will open a load circuit breaker. Also, the excessive current will cause the generator voltage to collapse. The result depends on the following items: electrical characteristics of the generator , type of fault and trip rating of the circuit breaker. An undervoltage device may be required to provide an adequate short circuit protection.There are some cases when the neutral wire is not grounded. An ungrounded generator neutral lead is acceptable when the possibility of grounds to the phase leads has been eliminated. An example of such measures is ground fault protective circuits. Ground fault protection requires the entire group of distribution circuits to be treated as a system. The owner should contact a certified consultant if a new distribution system is being developed. The owner should also contact a certified consultant if an existing system should be modified for the ground fault protection.Single Units
Each unit should be connected to a common ground.In a three-phase, four-wire system, the neutral wire should be grounded according to local wiring codes.Be sure to check your local wiring codes.Connection Diagrams
The generator lead connections are located in the terminal box on the generator or in the enclosure for the control panel.Change the position of the wire terminals to modify the connection. The code for the winding is specified on the nameplate.Wiring Code A for Three-Phase Configuration
Illustration 1 g00952030
Illustration 2 g00952058
Factory connection for "A" wiring code
Table 1
L-L Voltage for Wiring Code A
Winding 50 Hz 60 Hz
6 190-208 190-240
7 220-230 -
8 - 190-208 R 230 voltage sensing - 0 => (T8) / 110 V => (T11)R 438 LS voltage sensing - 0 => (T3) / 220 V => (T2)Wiring Code B for Single-Phase Configuration or Three-Phase Configuration
Illustration 3 g00952097
Illustration 4 g00952196
Factory connection for "B" wiring code


Back to top