11911-ZX2-000 Honda HANGER, ENGINE


11911-ZX2-000 HANGER, ENGINE Honda BF250A LA, BF250A XA, BF250A XCA, BF250A XXA, BF250A XXCA HANGER
11911-ZX2-000 HANGER, ENGINE Honda
Rating:
48

Buy HANGER, ENGINE 11911-ZX2-000 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$23.76
 

02-06-2022
0.5[0.00] Pounds
-: -
Honda 11911-ZX2-000 Hanger, Engine; 11911ZX2000 Made by Honda
Genuine, OEM Honda Replacement Part || Honda replacement engine hanger, part number 11911-ZX2-000
Number on catalog scheme: 2
 

Honda entire parts catalog list:

BF250A LA 2007
BF250A XA 2007
BF250A XCA 2007
BF250A XXA 2007
BF250A XXCA 2007

Information:


Illustration 1 g00605307
Illustration 2 g00605319 3E-1944 Electric Starting Motor When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 3628 413 rpmCurrent draw ... 84 16 AmpVoltage ... 23 Volt (1) Battery terminal nut Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (2) Ground terminal nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (3) Return terminal nut Tighten the nut on the return terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) Switch terminal Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Motor terminal nut Tighten the nut on the motor terminal to the following torque. ... 14.7 3.4 N m (130 30 lb in) (6) Motor frame nut Tighten the nut on the motor frame to the following torque. ... 8 3 N m (71 27 lb in)Clearance (X) between the pinion and the housing ... 1.02 0.76 mm (0.040 0.030 inch)SolenoidCurrent draw at 20 Volt and 25 °C (77 °F) Pull-in windings ... 36 2 AmpHold-in windings ... 6.75 Amp maximum 3E-2298 Electric Starting Motor 106-8559 Electric Starting Motor When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 8450 1250 rpmCurrent draw ... 65 15 AmpVoltage ... 23 Volt (1) Battery terminal nut Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (2) Ground terminal nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (3) Return terminal nut Tighten the nut on the return terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) Switch terminal Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Motor terminal nut Tighten the nut on the motor terminal to the following torque. ... 14.7 3.4 N m (130 30 lb in) (6) Motor frame nut Tighten the nut on the motor frame to the following torque. ... 8 3 N m (71 27 lb in)Clearance (X) between the pinion and the housing ... 4.6 mm (0.18 inch)SolenoidCurrent draw at 20 Volt and 25 °C (77 °F) Pull-in windings ... 56.5 4.5 AmpHold-in windings ... 14.6 Amp 7X-5987 Electric Starting Motor When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 7018 1517 rpmCurrent draw ... 147.5 27.5 AmpVoltage ... 11 Volt (1) Battery terminal nut Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (2) Ground terminal nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (3) Return terminal nut Tighten the nut on the return terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) Switch terminal Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Motor terminal nut Tighten the nut on the motor terminal to the following torque. ... 8 3 N m (71 27 lb in) (6) Motor frame nut Tighten the nut on the motor frame to the following torque. ... 8 3 N m (71 27 lb in)Clearance (X) between the pinion and the housing ... 1.02 0.76 mm (0.040 0.030 inch)SolenoidCurrent draw at 12 Volt and 25 °C (77 °F) Pull-in windings ... 89 5 AmpHold-in windings ... 23 2 Amp 9X-3416 Electric Starting Motor When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F) Speed ... 4050 750 rpmCurrent draw ... 68 10 AmpVoltage ... 24 Volt (1) Battery terminal nut Tighten the nut on the battery terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (2) Ground terminal nut Tighten the nut on the ground terminal to the following torque. ... 30.5 3.5 N m (23 3 lb ft) (3) Return terminal nut Tighten the nut on the return terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (4) Switch terminal Tighten the nut on the switch terminal to the following torque. ... 2.25 0.25 N m (20 2 lb in) (5) Motor terminal nut Tighten the nut on the motor terminal to the following torque. ... 8 3 N m (71 27 lb in) (6) Motor frame nut Tighten the nut on the motor frame to the following torque. ... 10 3 N m (7 2 lb ft)Clearance (X) between the pinion and the housing ... 1.78 0.25 mm (0.070 0.010 inch)SolenoidCurrent draw at 24 Volt and 25 °C (77 °F) Pull-in windings ... 44.5 2.5 AmpHold-in windings ... 7.5 0.6 Amp
Illustration 3 g00605377
Illustration 4 g00605392 3E-5381 Electric Starting Motor 9W-3748 Electric Starting Motor When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... ClockwiseNo load conditions at 25 °C (77 °F)


Back to top