22261-ZW6-030 Honda HOUSING, CLUTCH


22261-ZW6-030 HOUSING, CLUTCH Honda BF2.3DK2 LCHA, BF2.3DK2 SCHA, BF2D1 LCHA, BF2D1 SA, BF2D1 SAB, BF2D1 SCAB, BF2D1 SCHA, BF2D1 SHA, BF2D2 LCHA, BF2D2 SA, BF2D2 SAB, BF2D2 SCAB, BF2D2 SCHA, BF2D2 SHA, BF2D3 LCHA, BF2D3 SA, BF2D3 SAB, BF2D3 SCAB, BF2D3 SCHA, BF2D3 SHA, BF2D4 LCHA, BF2D HOUSING
22261-ZW6-030 HOUSING, CLUTCH Honda
Rating:
93

Buy HOUSING, CLUTCH 22261-ZW6-030 Honda genuine, new aftermarket parts with delivery
Number on catalog scheme: 9
 

Honda entire parts catalog list:

BF2.3DK2 LCHA 2007
BF2.3DK2 SCHA 2007
BF2D1 LCHA 2001
BF2D1 SA 2001
BF2D1 SAB 2001
BF2D1 SCAB 2001
BF2D1 SCHA 2001
BF2D1 SHA 2001
BF2D2 LCHA 2002
BF2D2 SA 2002
BF2D2 SAB 2002
BF2D2 SCAB 2002
BF2D2 SCHA 2002
BF2D2 SHA 2002
BF2D3 LCHA 2003
BF2D3 SA 2003
BF2D3 SAB 2003
BF2D3 SCAB 2003
BF2D3 SCHA 2003
BF2D3 SHA 2003
BF2D4 LCHA 2004
BF2D4 SA 2004
BF2D4 SAB 2004
BF2D4 SCAB 2004
BF2D4 SCHA 2004
BF2D4 SHA 2004
BF2D5 LCHA 2005
BF2D5 SCAB 2005
BF2D5 SCHA 2005
BF2D5 SHA 2005
BF2D6 LCHA 2006
BF2D6 SCAB 2006
BF2D6 SCHA 2006
BF2D6 SHA 2006
BF2DK0 LCHA 2007
BF2DK0 SCAB 2007
BF2DK0 SCHA 2007
BF2DX LCHA 1999
BF2DX SA 1999
BF2DX SAB 1999
BF2DX SCAB 1999
BF2DX SCHA 1999
BF2DY LCHA 2000
BF2DY SA 2000
BF2DY SAB 2000
BF2DY SCAB 2000
BF2DY SCHA 2000
BF2DY SHA 2000

Information:


Illustration 1 g03659437
(A) Sea water inlet (B) Sea water outlet (1) Coolant temperature sensor (2) Aftercooler (3) Fuel cooler (4) Auxiliary sea water pump (5) Sea water pressure sensor (6) Engine oil cooler (7) Water pump (8) Heat exchanger (9) Transmission oil cooler - if equipped (10) Coolant level switch (11) Coolant expansion tankCoolant Flow Circuit
Illustration 2 g03660446
(6) Heat exchanger (7) Water pump (12) Cylinder head (13) Turbine housing (14) Exhaust manifold (15) Coolant expansion tank (16) Temperature regulatorThe water pump is located on the front of the cylinder block. The water pump is belt-driven from the crankshaft pulley.Coolant from the heat exchanger is pulled into the inlet of the water pump by impeller rotation. The coolant exits the pump directly into the engine oil cooler.After the water exits the oil cooler, the water is dispersed to three main components: cylinder block and head, turbocharger and exhaust manifold.The coolant that was directed to the cylinder block next flows into the cylinder head.The coolant exits the cylinder head and combines with the flow of coolant from the exhaust manifold and the turbocharger. The combined coolant then flows to the water temperature regulator. The coolant then flows through a deaerator in order to purge excess air to the expansion tank. The water is then returned to the heat exchanger in order to be cooled.Air vents are provided on the water outlet of the turbocharger. The air vents aid in removing air from the system during the initial filling of the cooling system. The air vents also aid in removing air from the system after a flushing process.Note: The water temperature regulator controls the direction of flow. When the coolant temperature is below the normal operating temperature, the water temperature regulator is closed. The coolant is directed from the cylinder head to the inlet of the water pump. When the coolant temperature reaches the normal operating temperature, the water temperature regulator opens. Coolant then travels to the heat exchanger for cooling.Note: The water temperature regulator is an important part of the cooling system. The water temperature regulator divides coolant flow between the heat exchanger and the bypass in order to maintain the normal operating temperature. If the water temperature regulator is not installed in the system, there is no mechanical control, and most of the coolant will travel the path of least resistance through the bypass. This action will cause the engine to overheat in hot weather and the engine will not reach normal operating temperature in cold weather.Raw Water Circuit
Illustration 3 g03660436
(A) Sea water inlet (B) Sea water outlet (2) Aftercooler (3) Fuel cooler (8) Heat exchanger (9) Transmission oil cooler - if equipped (17) Sea water-cooled exhaust riser - if equippedIn many instances, a separate cooling source is used to supply coolant to the aftercooler. The coolant supply can be fresh water, or the coolant supply can be sea water. Because of the possible unknown composition of the cooling water, a special pump is needed to move the coolant through the system. Two types of pumps are available for use in the raw water circuit.
A bronze pump is used when sea water enters the system. This type of pump will resist the corrosive action of the coolant that passes through the pump.
A cast iron pump is used when the coolant is pure and noncorrosive. Raw water is drawn in through the inlet of the auxiliary water pump. The raw water will flow through the fuel cooler before the auxiliary water pump inlet if the engine is equipped with the optional fuel cooler. The raw water is forced out of the pump and into the aftercooler. The raw water flows through the aftercooler and exits at the end of the aftercooler. The raw water then travels through the marine gear cooler(if equipped), the heat exchanger, and the exhaust elbow (if equipped). The raw water is then discharged.Heat Exchanger
Inboard mounted heat exchangers are typically designed as a shell that surrounds many thin tubes. Systems that are cooled with a heat exchanger require a sea water pump in order to circulate sea water through the thin tubes in the heat exchanger. Cooling system water is then circulated in the opposite direction through the shell that surrounds the tubes. Heat is transferred from the hot coolant to the cool sea water that is flowing through the thin tubes.


Parts housing Honda:

53168-GAH-700
 
53168-GAH-700 HOUSING, THROTTLE (UPPER) (Honda Code 6007843).
BF2.3DK2 LCHA, BF2.3DK2 SCHA, BF2D1 LCHA, BF2D1 SAB, BF2D1 SCAB, BF2D1 SCHA, BF2D1 SHA, BF2D2 LCHA, BF2D2 SAB, BF2D2 SCAB, BF2D2 SCHA, BF2D2 SHA, BF2D3 LCHA, BF2D3 SAB, BF2D3 SCAB, BF2D3 SCHA, BF2D3 SHA, BF2D4 LCHA, BF2D4 SAB, BF2D4 SCAB, BF2D4 SCHA,
Back to top