08M60-ZW7-B00 PROPELLER, THREE-BLADE (Honda Code 5806104). (13-1/4X15) (CR) Honda
BF115A1 LCA, BF115A1 XCA, BF115A2 LCA, BF115A2 XCA, BF115A3 LCA, BF115A3 XCA, BF115A4 LCA, BF115A4 XCA, BF130A1 LCA, BF130A1 XCA, BF130A2 LCA, BF130A2 XCA, BF130A3 LCA, BF130A3 XCA, BF130A4 LCA, BF130A4 XCA
PROPELLER
Price: query
Rating:
Compatible models:
Honda entire parts catalog list:
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER KIT » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
- PROPELLER » 08M60-ZW7-B00
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
3563-13
Engine Intake Manifold #1 Absolute Pressure : Out of Calibration 1785-13
Intake Manifold Pressure Sensor : Out of Calibration During key on, the signal voltage from the intake manifold pressure sensor indicated an intake manifold pressure greater than +/- 18 kPa (3 psi).
Reference sensor: Atmospheric Pressure Sensor
3563–21
Engine Intake Manifold #1 Absolute Pressure : Data Drifted Low 1785–21
Intake Manifold Pressure Sensor : Data Drifted Low The 5 VDC supply to the sensor has been lost.
The code is logged.
Table 2
Troubleshooting Test Steps Values Results
1. Check for Codes
Note: The engine coolant temperature must be greater than 0° C (32° F) before beginning this procedure.
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Look for active codes that are associated with the system for the event code.
Codes
Result: An associated code is active.
Repair: Troubleshoot any associated codes before continuing with this test.
Result: A code is active or logged.
Proceed to Test Step 2.
2. Check for Debris
A. Turn the keyswitch to the OFF position.
B. Check the sensor for debris.
C. If applicable, check the reference sensor for debris.
D. Check the sensor measurement port for blockage by debris.
E. If debris is found, clear the debris from the measurement port and replace the sensor.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Debris
Result: The sensor measurement port is not blocked by debris.
Proceed to Test Step 3.
Result: A -13 code is not active.
Return to service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 3.
3. Inspect the Sensor Connector
A. Turn the keyswitch to the OFF position.
B. Inspect the sensor connector for moisture and corrosion.
Moisture
Result: The sensor connector does not have moisture or corrosion.
Proceed to Test Step 5.
Result: The sensor connector has moisture and/or corrosion.
Proceed to Test Step 4.
4. Remove any moisture and/or corrosion
A. Turn the keyswitch to the OFF position.
B. Disconnect the sensor connector.
C. Remove any moisture and/or corrosion from the outside of the connector. Check for moisture and corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following code:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
If the problem is not resolved, proceed to Test Step 5.
5. Check for Moisture and/or Corrosion in the Circuit
A. Turn the keyswitch to the OFF position.
B. Check all the connectors in the circuit for moisture and/or corrosion.
C. Check for corrosion inside the connector. Verify that the seals for the wires are sealing correctly. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information.
D. If necessary, repair or replace the connector.
E. Reconnect the connector. Verify that the connection is secure.
F. Connect Cat ET.
G. Use Cat ET to monitor the following:
- Codes
Moisture
Result: A -13 code is not active.
Return the service.
Result: A -13 code is active.
Repair: Replace the sensor. If more than one -13 code is active and the codes have a reference sensor, replace the reference sensor.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts propeller Honda:
08M60-ZW7-B30
08M60-ZW7-B30 PROPELLER, THREE-BLADE (Honda Code 5806138). (13-1/4X21) (CR)
BF115A1 LCA, BF115A1 XCA, BF115A2 LCA, BF115A2 XCA, BF115A3 LCA, BF115A3 XCA, BF115A4 LCA, BF115A4 XCA, BF130A1 LCA, BF130A1 XCA, BF130A2 LCA, BF130A2 XCA, BF130A3 LCA, BF130A3 XCA, BF130A4 LCA, BF130A4 XCA
08M60-ZW7-B20
08M60-ZW7-B20 PROPELLER, THREE-BLADE (Honda Code 5806120). (13-1/4X19) (CR)
BF115A1 LCA, BF115A1 XCA, BF115A2 LCA, BF115A2 XCA, BF115A3 LCA, BF115A3 XCA, BF115A4 LCA, BF115A4 XCA, BF130A1 LCA, BF130A1 XCA, BF130A2 LCA, BF130A2 XCA, BF130A3 LCA, BF130A3 XCA, BF130A4 LCA, BF130A4 XCA
08M60-ZW7-B10
08M60-ZW7-B10 PROPELLER, THREE-BLADE (Honda Code 5806112). (13-1/4X17) (CR)
BF115A1 LCA, BF115A1 XCA, BF115A2 LCA, BF115A2 XCA, BF115A3 LCA, BF115A3 XCA, BF115A4 LCA, BF115A4 XCA, BF130A1 LCA, BF130A1 XCA, BF130A2 LCA, BF130A2 XCA, BF130A3 LCA, BF130A3 XCA, BF130A4 LCA, BF130A4 XCA