28441-848-650 Honda RATCHET, STARTER (Honda Code 0438614).


28441-848-650 RATCHET, STARTER (Honda Code 0438614). Honda BF8A3 LA, BF8A3 SA, BF8A4 LA, BF8A4 SA, BF8A5 LA, BF8A5 SA, BF8A6 LA, BF8A6 SA, BF8AK0 LA, BF8AK0 SA, BF8AM LA, BF8AM SA, BF8AM XA, BF8AW LA, BF8AW SA, BF8AW XA, BF8AX LA, BF8AX SA, BF8AX XA, BF8AY LA, BF8AY SA, BF8AY XA RATCHET
28441-848-650 RATCHET, STARTER (Honda Code 0438614). Honda
Rating:
83

Buy RATCHET, STARTER (Honda Code 0438614). 28441-848-650 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$12.00
 

11-05-2023
0.25[0.11] Pounds
-: -
Honda 28441-848-650 Ratchet Starter
Honda 28441-848-650 Ratchet Starter
Number on catalog scheme: 4
 

Honda entire parts catalog list:

BF8A3 LA 2003
BF8A3 SA 2003
BF8A4 LA 2004
BF8A4 SA 2004
BF8A5 LA 2005
BF8A5 SA 2005
BF8A6 LA 2006
BF8A6 SA 2006
BF8AK0 LA 2007
BF8AK0 SA 2007
BF8AM LA 1997
BF8AM SA 1997
BF8AM XA 1997
BF8AW LA 1998
BF8AW SA 1998
BF8AW XA 1998
BF8AX LA 1999
BF8AX SA 1999
BF8AX XA 1999
BF8AY LA 2000
BF8AY SA 2000
BF8AY XA 2000

Information:


Use of commercially available cooling system cleaners may cause damage to cooling system components. Use only cooling system cleaners that are approved for Caterpillar engines.
When any servicing or repair of the engine cooling system is performed, the procedure must be performed with the engine on level ground. This procedure will allow you to accurately check the coolant level. This procedure will also help in avoiding the risk of introducing an air lock into the coolant system.
Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This inspection is a good opportunity to replace the water pump, the water temperature regulator, and the hoses, if necessary. Drain
Pressurized System: Hot coolant can cause serious burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pressure.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Note: Refer to Operation and Maintenance Manual, "General Hazard Information" for information on Containing Fluid Spillage.
Illustration 1 g02119093
Typical example
Open the drain cock or remove the drain plug (1) on the engine. Also remove the drain plug (2). Open the drain cock or remove the drain plug on the radiator. Note: Some applications have two drain plugs on the cooler, only one is required for draining.Allow the coolant to drain into a suitable container.
Properly dispose of the drained material. Obey local regulations for the disposal of the material.
Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant.
Flush
Flush the cooling system with clean water in order to remove any debris.
Close the drain valves (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques. Cooling Systems with Heavy Deposits or Plugging
Note: For the following procedure to be effective, there must be some active flow through the cooling system components.
Flush the cooling system with clean water in order to remove any debris.
Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques.
Do not fill the cooling system faster than 5 L (1.3 US gal) per minute to avoid air locks.Cooling system air locks may result in engine damage.
Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap.
Start and run the engine at low idle for a minimum of 90 minutes. The coolant temperature should be at least 82 °C (180 °F).
Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal components.To avoid damage to the cooling system, make sure to completely flush the cooling system with clear water. Continue to flush the system until all signs of the cleaning agent are gone.
Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to Torque Specifications, SENR3130 for more information on the correct torques. Fill


Back to top