24320-ZV4-000 Honda ROD A, SHIFT (Honda Code 2796217).


24320-ZV4-000 ROD A, SHIFT (Honda Code 2796217). Honda BF15A1 LA, BF15A1 LAS, BF15A1 SA, BF15A1 SAS, BF15A1 XAS, BF15A2 LA, BF15A2 LAS, BF15A2 SA, BF15A2 SAS, BF15A2 XAS, BF15AM LA, BF15AM LAS, BF15AM SA, BF15AM SAS, BF15AM XAS, BF15AW LA, BF15AW LAS, BF15AW SA, BF15AW SAS, BF15AW XAS, BF15AX LA, BF15AX ROD

Buy ROD A, SHIFT (Honda Code 2796217). 24320-ZV4-000 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$34.44
 

06-05-2021
0.25[0.00] Pounds
-: -
Honda 24320-ZV4-000 Rod A Shift
Honda 24320-ZV4-000 Rod A Shift
Number on catalog scheme: 10
 

Honda entire parts catalog list:

BF15A1 LA 2001
BF15A1 LAS 2001
BF15A1 SA 2001
BF15A1 SAS 2001
BF15A1 XAS 2001
BF15A2 LA 2002
BF15A2 LAS 2002
BF15A2 SA 2002
BF15A2 SAS 2002
BF15A2 XAS 2002
BF15AM LA 1997
BF15AM LAS 1997
BF15AM SA 1997
BF15AM SAS 1997
BF15AM XAS 1997
BF15AW LA 1998
BF15AW LAS 1998
BF15AW SA 1998
BF15AW SAS 1998
BF15AW XAS 1998
BF15AX LA 1999
BF15AX LAS 1999
BF15AX SA 1999
BF15AX SAS 1999
BF15AX XAS 1999
BF15AY LA 2000
BF15AY LAS 2000
BF15AY SA 2000
BF15AY SAS 2000
BF15AY XAS 2000
BF9.9AM LA 1997
BF9.9AM LAS 1997
BF9.9AM SA 1997
BF9.9AM SAS 1997
BF9.9AM XA 1997
BF9.9AM XAS 1997
BF9.9AW LA 1998
BF9.9AW LAS 1998
BF9.9AW SA 1998
BF9.9AW SAS 1998
BF9.9AW XA 1998
BF9.9AW XAS 1998
BF9.9AX LA 1999
BF9.9AX LAS 1999
BF9.9AX SA 1999
BF9.9AX SAS 1999
BF9.9AX XA 1999
BF9.9AX XAS 1999
BF9.9AY LA 2000
BF9.9AY LAS 2000
BF9.9AY SA 2000
BF9.9AY SAS 2000
BF9.9AY XA 2000
BF9.9AY XAS 2000

Information:


Table 1
Typical Voltage Of Electrical System During Cranking At Various Ambient Temperatures
Temperature 12 V System 24 V System
−23 to −7°C (−10 to 20°F) 6 to 8 V 12 to 16 V
−7 to 10°C (20 to 50°F) 7 to 9 V 14 to 18 V
10 to 27°C (50 to 80°F) 8 to 10 V 16 to 24 V Table 2 shows the maximum acceptable loss of voltage in the battery circuit. The battery circuit supplies high current to the starting motor. The values in the table are for engines which have service of 2000 hours or more.
Table 2
Maximum Acceptable Voltage Drop In The Starting Motor Circuit During Cranking
Circuit 12 V System 24 V System
Battery post "-" to the starting motor terminal "-" 0.7 V 1.4 V
Drop across the disconnect switch 0.5 V 1.0 V
Battery post "+" to the terminal of the starting motor solenoid "+" 0.5 V 1.0 V
Solenoid terminal "Bat" to the solenoid terminal "Mtr" 0.4 V 0.8 V Voltage drops that are greater than the amounts in table 2 are caused most often by the following conditions:
Loose connections
Corroded connections
Faulty switch contactsDiagnosis Procedure
The procedures for diagnosing the starting motor are intended to help the technician determine if a starting motor needs to be replaced or repaired. The procedures are not intended to cover all possible problems and conditions. The procedures serve only as a guide.
If equipped with electric start, do not crank the engine for more than 30 seconds. Allow the starter to cool for two minutes before cranking again.Never turn the disconnect switch off while the engine is running. Serious damage to the electrical system can result.
If the starting motor does not crank or cranks slow, perform the following procedure:
Measure the voltage of the battery. Measure the voltage across the battery posts with the multimeter when you are cranking the engine or attempting to crank the engine. Do not measure the voltage across the cable post clamps.
If the voltage is equal to or greater than the voltage in table 1, then go to step 2.
The battery voltage is less than the voltage in Table 1. A low charge in a battery can be caused by several conditions.
Deterioration of the battery
A shorted starting motor
A faulty alternator
Loose drive belts
Current leakage in another part of the electrical system
Measure the current that is sent to the starting motor solenoid from the positive post of the battery. Note: If the following conditions exist, do not perform the test in step 2 because the starting motor has a problem.
The voltage at the battery post is within 2 V of the lowest value in the applicable temperature range of table 1.
The large starting motor cables get hot.Use a suitable ammeter in order to measure the current. Place the jaws of the ammeter around the cable that is connected to the "bat" terminal. Refer to Specifications, "Starter Motor" for the maximum current that is allowed for no load conditions.The current and the voltages that are specified in Specifications are measured at a temperature of 27°C (80°F). When the temperature is below 27°C (80°F), the voltage will be lower through the starting motor. When the temperature is below 27°C (80°F), the current through the starting motor will be higher. If the current is too great, a problem exists in the starting motor. Repair the problem or replace the starting motor.If the current is within the specification, proceed to step 3.
Measure the voltage of the starting motor.
Use the multimeter in order to measure the voltage of the starting motor, when you are cranking or attempting to crank the engine.
If the voltage is equal to or greater than the voltage that is given in table 1, then the battery and the starting motor cable that goes to the starting motor are within specifications. Go to step 5.
The starting motor voltage is less than the voltage specified in table 1. The voltage drop between the battery and the starting motor is too great. Go to step 4.
Measure the voltage.
Measure the voltage drops in the cranking circuits with the multimeter. Compare the results with the voltage drops which are allowed in table 2.
Voltage drops are equal to the voltage drops that are given in table 2 or the voltage drops are less than the voltage drops that are given in Table 2. Go to step 5 in order to check the engine.
The voltage drops are greater than the voltage drops that are given in table 2. The faulty component should be repaired or replaced.
Rotate the crankshaft by hand in order to ensure that the crankshaft is not stuck. Check the oil viscosity and any external loads that could affect the engine rotation.
If the crankshaft is stuck or difficult to turn, repair the engine.
If the engine is not difficult to turn, go to step 6.
Attempt to crank the starting motor.
The starting motor cranks slowly. Remove the starting motor for repair or replacement.
The starting motor does not crank. Check for the blocked engagement of the pinion gear and flywheel ring gear.Note: Blocked engagement and open solenoid contacts will give the same electrical symptoms.


Parts rod Honda:

16593-881-010
 
16593-881-010 ROD, THROTTLE (Honda Code 0497651).
BF8A3 LA, BF8A3 SA, BF8A4 LA, BF8A4 SA, BF8A5 LA, BF8A5 SA, BF8A6 LA, BF8A6 SA, BF8AK0 LA, BF8AK0 SA, BF8AM LA, BF8AM SA, BF8AM XA, BF8AW LA, BF8AW SA, BF8AW XA, BF8AX LA, BF8AX SA, BF8AX XA, BF8AY LA, BF8AY SA, BF8AY XA
16622-881-000
 
16622-881-000 ROD, CHOKE (Honda Code 0497669).
BF8A3 LA, BF8A3 SA, BF8A4 LA, BF8A4 SA, BF8A5 LA, BF8A5 SA, BF8A6 LA, BF8A6 SA, BF8AK0 LA, BF8AK0 SA, BF8AM LA, BF8AM SA, BF8AM XA, BF8AW LA, BF8AW SA, BF8AW XA, BF8AX LA, BF8AX SA, BF8AX XA, BF8AY LA, BF8AY SA, BF8AY XA
24310-881-701
 
24310-881-701 ROD, GEARSHIFT (L) (Honda Code 3131570).
BF8A3 LA, BF8A4 LA, BF8A5 LA, BF8A6 LA, BF8AK0 LA, BF8AM LA, BF8AW LA, BF8AX LA, BF8AY LA
16593-ZV4-000
ROD, THROTTLE (Honda Code 2795201).
16593-ZV4-000 ROD, THROTTLE (Honda Code 2795201).
BF15A1 LA, BF15A1 LAS, BF15A1 SA, BF15A1 SAS, BF15A1 XAS, BF15A2 LA, BF15A2 LAS, BF15A2 SA, BF15A2 SAS, BF15A2 XAS, BF15AM LA, BF15AM LAS, BF15AM SA, BF15AM SAS, BF15AM XAS, BF15AW LA, BF15AW LAS, BF15AW SA, BF15AW SAS, BF15AW XAS, BF15AX LA, BF15AX
16622-ZV4-000
ROD, CHOKE (Honda Code 2795219).
16622-ZV4-000 ROD, CHOKE (Honda Code 2795219).
BF15A1 LA, BF15A1 LAS, BF15A1 SA, BF15A1 SAS, BF15A1 XAS, BF15A2 LA, BF15A2 LAS, BF15A2 SA, BF15A2 SAS, BF15A2 XAS, BF15AM LA, BF15AM LAS, BF15AM SA, BF15AM SAS, BF15AM XAS, BF15AW LA, BF15AW LAS, BF15AW SA, BF15AW SAS, BF15AW XAS, BF15AX LA, BF15AX
17955-ZV4-000
 
17955-ZV4-000 ROD, CHOKE KNOB (Honda Code 2795722).
BF15A1 LA, BF15A1 LAS, BF15A1 SA, BF15A1 SAS, BF15A1 XAS, BF15A2 LA, BF15A2 LAS, BF15A2 SA, BF15A2 SAS, BF15A2 XAS, BF15AM LA, BF15AM LAS, BF15AM SA, BF15AM SAS, BF15AM XAS, BF15AW LA, BF15AW LAS, BF15AW SA, BF15AW SAS, BF15AW XAS, BF15AX LA, BF15AX
24310-ZV4-701
 
24310-ZV4-701 ROD, SHIFT (L) (Honda Code 3174489).
BF15A1 LA, BF15A1 LAS, BF15A2 LA, BF15A2 LAS, BF15AM LA, BF15AM LAS, BF15AW LA, BF15AW LAS, BF15AX LA, BF15AX LAS, BF15AY LA, BF15AY LAS, BF9.9AM LA, BF9.9AM LAS, BF9.9AW LA, BF9.9AW LAS, BF9.9AX LA, BF9.9AX LAS, BF9.9AX XA, BF9.9AX XAS, BF9.9AY LA,
24311-ZV4-700
 
24311-ZV4-700 ROD B, SHIFT (L) (Honda Code 2796183).
BF15A1 LA, BF15A1 LAS, BF15A2 LA, BF15A2 LAS, BF15AM LA, BF15AM LAS, BF15AW LA, BF15AW LAS, BF15AX LA, BF15AX LAS, BF15AY LA, BF15AY LAS, BF9.9AM LA, BF9.9AM LAS, BF9.9AW LA, BF9.9AW LAS, BF9.9AX LA, BF9.9AX LAS, BF9.9AX XA, BF9.9AX XAS, BF9.9AY LA,
Back to top