90518-ZW1-003 Honda SHIM, GEAR (Honda Code 4857058).


90518-ZW1-003 SHIM, GEAR (Honda Code 4857058). Honda BF75AT LHTA, BF75AT LRTA, BF75AT XRTA, BF75AW LHTA, BF75AW LRTA, BF75AW XRTA, BF90AT LHTA, BF90AT LRTA, BF90AT XRTA, BF90AW LHTA, BF90AW LRTA, BF90AW XRTA SHIM
90518-ZW1-003 SHIM, GEAR (Honda Code 4857058). Honda
Rating:
53

Buy SHIM, GEAR (Honda Code 4857058). 90518-ZW1-003 Honda genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$30.59
 

25-08-2024
0.5625[0.25] pounds
US: PowerToolReplacement
Honda 90518-ZW1-003 Shim Gear
Honda Genuine, OEM Honda Replacement Part || Honda replacement gear shim, part number 90518-ZW1-003
Number on catalog scheme: 22
 

Honda entire parts catalog list:

BF75AT LHTA 1997
BF75AT LRTA 1997
BF75AT XRTA 1997
BF75AW LHTA 1998
BF75AW LRTA 1998
BF75AW XRTA 1998
BF90AT LHTA 1997
BF90AT LRTA 1997
BF90AT XRTA 1997
BF90AW LHTA 1998
BF90AW LRTA 1998
BF90AW XRTA 1998

Information:


Table 1
Diagnostic Codes Table    
Code and Description     Conditions which Generate this Code     System Response    
337-2 Engine Auxiliary Engine Shutdown Switch : Erratic, Intermittent, or Incorrect     The two inputs from the emergency stop switch are in the opposite state.     The code is logged.    The Electronic Control Module (ECM) receives two signals from the emergency stop switch. The signals allow the ECM to determine the status of the emergency stop switch. The ECM will shut down the engine when both of the signals are open. When both of the signals are connected to the −Battery the emergency stop switch is not active, and the engine will run. If two different signals are detected during the powerup, the ECM will determine that one of the signals is incorrect. A diagnostic code will be logged and a diagnostic code will remain active. The engine will continue to run when the ECM detects two different signals. If both of the signals are open, the engine will stop.The customer can install multiple emergency stop switches. When the Engine Control Switch (ECS) is turned to the ON position, the engine will begin the sequence for start-up.When the emergency stop switch is activated, the ECM will stop firing the injectors. The engine will stop. When an emergency stop is received by the ECM, the ECM will activate the output for the solenoid valve that controls the air shutoff valve. When the solenoid valve activates, the air shutoff valve closes removing the intake air to the engine. Manually open the air shutoff valve in order to start the engine.Note: The air shutoff is optional. Set the programmable parameter with Caterpillar Electronic Technician (ET) in order to enable the air shutoff. The 970-31 Engine Auxiliary Engine Shutdown Switch event code will be set when the remote emergency stop switch is activated. This event will prevent engine operation. Electrical power to the ECM must be removed for 3 seconds in order to clear this event.
Illustration 1 g03364434
Typical schematic
Illustration 2 g03323450
Terminal locations at the P1 ECM connector (P1-5) Digital return (P1-23) E-Stop 1 (P1-28) E-Stop 2
Table 2
Troubleshooting Test Steps    Values    Results    
1. Inspect the Electrical Connectors and the Wiring
A. Turn the main disconnect switch to the OFF position.
B. Thoroughly inspect the ECM connectors. Also, inspect the connectors at the air shutoff mechanism that are for the solenoids. Also, inspect the switches for the air shutoff. Refer to Troubleshooting, "Electrical Connectors - Inspect"
C. Perform a
45 N (10 lb) pull test on each of the wires that are associated with the e-top circuit.
D. Check the allen head screw on each ECM connector for the proper torque. Refer to the diagnostic functional test Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
E. Check the harness and the wiring for abrasion and for pinch points from the air shutoff solenoid to the ECM.
   
Connectors    
Results: The connectors and wiring appear to be OK.
Proceed to Test Step 2
Results: The connectors and/or wiring are not OK.
Repair: Repair the wiring and/or the connectors. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are coupled.
Verify that the repair eliminated the problem.
   
2. Check for Logged Codes
A. Connect Cat ET to the service tool connector.
B. Restore the electrical power to the ECM.
C. Start Cat ET
D. Check for an active 337-2 code.
Note: Wait at least 30 seconds in order for diagnostic codes to become active.
- Restore the wiring to the original configuration.
   
Codes    
Results: A 337-2 code is not active.
Proceed to Test Step 4.
Results: A 337-2 code is active.
Repair: The wires between the ECM and the remote e-stop are in opposite states. Proceed to Test Step 3.
   
3. Check for an Open Circuit
A. Disconnect the J1/P1 ECM connector.
B. Measure the resistance between P1-23 at the ECM connector and terminal 2 at the emergency stop switch.
C. Measure the resistance between P1-28 at the ECM connector and terminal 2 at the emergency stop switch.
   
Open Circuit    
Results: The measurements do not indicate an open circuit.
Proceed to Test Step 4.
Results: At lease one of the measurements indicate an open circuit
Repair: Determine the cause of the open circuit. Repair the problem, when possible. Replace parts, if necessary.
Verify that the repair eliminates the problem.
   
4. Check the status while the Remote Emergency Stop Switch is Active
A. Restore electrical power to the ECM.
B. Stat Cat ET.
C. Observe the status of the remote emergency stop switch using Cat ET.
D. Activate the emergency stop switch. If multiple remote emergency stop switches have been installed, ensure that any other remote emergency stop switch has not been activated.
   
ON    
Results: The status of the emergency stop switch reads ON. The switch is working properly.
Proceed to Test Step 5.
Results: The status of the emergency stop switch does not read ON.
Proceed to Test Step 6.
   
5. Check the Status while the Remote Emergency Stop Switch is Not Active
A. Deactivate the remote emergency stop switch.
Note: Ensure that the solenoid valves retract and that the air shutoff valves are open.
B. Observe the status of the remote emergency stop switch using Cat ET.    
OFF    
Results: The status of the remote emergency stop switch displays OFF.
Repair: The remote emergency stop switch is functioning properly. There may be an intermittent problem. If the problem is intermittent, refer to Troubleshooting, "Electrical Connectors - Inspect".
Results: The status of the remote emergency stop switch does not display OFF.
Proceed to Test Step 6.    
6. Check for Proper Operation of the ECM
A. Disconnect the J1/P1 ECM connectors.
B. Fabricate a jumper wire that is long enough to use as a test lead at the ECM connector. Crimp a connector socket to one end of the jumper wire.
C. Remove the P1-23 and P1-28 wires from terminal location at the ECM connector. Install the jumper wire into the P1-23 and P1-28 terminal locations.
D. Connect the J1/P1 ECM connectors.
E. Restore the electrical power to the ECM.
F. Measure the voltage between the jumper wire and the engine ground stud while you


Parts shim Honda:

90528-ZW1-003
SHIM, BEVEL GEAR (F) (Honda Code 4857447).
90528-ZW1-003 SHIM, BEVEL GEAR (F) (Honda Code 4857447).
BF75AT LHTA, BF75AT LRTA, BF75AT XRTA, BF75AW LHTA, BF75AW LRTA, BF75AW XRTA, BF90AT LHTA, BF90AT LRTA, BF90AT XRTA, BF90AW LHTA, BF90AW LRTA, BF90AW XRTA
Back to top