0387374 JOHNSON BEARING HSG.SEAL ASSY.


0387374 BEARING HSG.SEAL ASSY. JOHNSON 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, J150TLCIA, J150TLCNM, J150TLCSF, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCSA, J175TLCTD, J200TLCIH, J200TLCNE, J200TLCSF, J200TLCTD, J235TLCI BEARING
0387374 BEARING HSG.SEAL ASSY. JOHNSON
Rating:
93

Buy BEARING HSG.SEAL ASSY. 0387374 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$76.99
 

08-09-2017
4.00[1.80] pounds
OMC: OMC
0387374 Bearing Housing and Seal Assembly for OMC Chevy Stringer Stern Drives 387374
OMC||0387374||Used, freshwater part, needle bearings are smooth||1976-83||150, 175, 200, 235
Number on catalog scheme: 24
 

BRP JOHNSON entire parts catalog list:

150TL78S, 150TXL78S 1978
150TL79C, 150TXL79C 1979
175TL77S, 175TXL77S 1977
175TL78C, 175TX78C 1978
175TL79R, 175TXL79R 1979
200TL76S, 200TXL76S 1976
200TL77C, 200TXL77C 1977
200TL78R, 200TX78R 1978
200TL79A, 200TXL79A 1979
235TL70A, 235TXL79A 1979
235TL78R, 235TX78R 1978
J150TLCIA, J150TLCIH, J150TXCIA, J150TXCIH 1981
J150TLCNM, J150TXCNM 1982
J150TLCSF, J150TLCSR, J150TXCSF, J150TXCSR 1980
J150TLCTB, J150TLCTE, J150TXCTB, J150TXCTE 1983
J175TLCIH, J175TLCIM, J175TXCIH, J175TXCIM 1981
J175TLCNB, J175TXCNB 1982
J175TLCSA, J175TLCSF, J175TXCSA, J175TXCSF 1980
J175TLCTD, J175TLCTE, J175TXCTD, J175TXCTE 1983
J200TLCIH, J200TXCIB, J200TXCIH 1981
J200TLCNE, J200TXCNE 1982
J200TLCSF, J200TLCSM, J200TXCSF, J200TXCSM 1980
J200TLCTD, J200TLCTS, J200TXCTD, J200TXCTS 1983
J235TLCIB, J235TLCIH, J235TXCIB, J235TXCIH 1981
J235TLCNE, J235TXCNE 1982
J235TLCSM, J235TXCSM 1980
J235TLCTD, J235TLCTS, J235TXCTD, J235TXCTS 1983

Information:


Illustration 1 g00800583
EMCP II+ (1) Generator set control+ (GSC+) (2) Upper display (3) Lower display (4) Alarm module (ALM) (5) Custom Alarm module (CAM) (6) Speed potentiometer (7) Start Aid switch (8) Voltage adjust rheostat (9) Caterpillar monitoring system control (10) Scroll switch (11) Display mode (12) Fault alarm indicators (13) Keypad (14) Emergency stop push button (ESPB) (15) Panel lights (16) Engine control switch (ECS) (17) "LH/RH switch"
Illustration 2 g00800584
EMS II (1) Display mode (2) Scroll switch (3) Display module (4) Engine oil pressure (5) Engine coolant temperature (6) Engine intake manifold pressure (7) Engine exhaust temperature (8) Reset push button (9) "LH/RH switch" (10) Battery monitor (11) Engine oil temperature (12) Engine inlet air temperature (13) Fuel pressure (14) Emergency stop push button (ESPB) (15) Engine control switch (ECS)EMCP II+
The EMCP II+ consists of the following components: Generator Set Control+ (GSC+), Instrument Panel, Alarm Module and Synchronizing Light Module. Refer to Illustration 1.Generator Set Control+ (GSC+)
The main component of the EMCP II+ system is the generator set control+ (GSC+) (1). The GSC+ is designed to operate when the GSC+ is powered by 24 VDC or 32 VDC. The GSC+ monitors the generator set. The GSC+ controls many of the functions of the generator set. The GSC+ has four main components: fault indicators, upper display, lower display and keypad.Fault Indicators
The ten fault indicators (12) are used in order to show a fault that is present. The ten fault indicators are also used to describe a fault that is present. The fault indicators are divided into four groups. The four groups are the fault alarm indicator, the spare fault indicators, the fault shutdown indicator and the dedicated shutdown indicators.Upper Display
The primary function of the upper display (2) is showing the following information of the generator output: AC voltage, current and frequency. Several options are available on the upper display for AC metering. These options can be viewed one at a time by pressing the AC Meter key on the keypad.Lower Display
The lower display (3) shows values for power metering, engine parameters and the relay status. The left side of the lower display serves as a power meter for the generator set.Keypad
The keypad (13) is used to control the information that is shown on upper display (2) and lower display (3). The seven keys have two sets of functions, normal functions and service functions. See the topic Systems Operation, "Service Mode" for a description of the service functions of the keys. The normal functions of the keys are described in the following paragraphs.Power Meter Key - This key controls the viewing of power meter information. This information is shown on the lower display. Pressing the key for at least five seconds causes all the power meter data to scroll once. The default power meter data then resumes scrolling. Briefly pressing this key for less than five seconds will stop the scrolling of the power meter functions, until the key is pressed again. AC Meter Key - The AC meter key controls the viewing of the AC parameters on the upper display. Pressing the key causes the display to show a different set of parameters.Engine Meter Key - This key controls the viewing of engine parameters on the lower display. Pressing the key stops the scrolling of engine conditions. The value for one particular engine condition will show continuously. The pointer flashes indicating that the scrolling is stopped. The scrolling of the engine conditions will resume when the engine meter key is pressed again.Lamp Test Key - Pressing this key performs a lamp test on the GSC+ and the optional alarm module. On the GSC+, the ten fault indicators are ON CONTINUOUSLY. Every segment of upper display (2) and lower display (3) are ON. On the optional alarm module, all of the indicators are ON and the horn sounds. The lamp test function automatically turns off when the key is held on for more than ten seconds. Alarm Code Key - If fault alarm indicator is FLASHING, pressing this key causes the upper display (2) to show the corresponding alarm fault code. If the alarm code key is pressed again the upper display reverts to the previous display. If fault alarm indicator is OFF, this key has no function. For more information on alarm fault codes, see Systems Operation, "Fault Description".Exit Key - This key only functions when the GSC + is in Service Mode. See Systems Operation, "Service Mode".Service Mode Key - Pressing this key causes the GSC+ to enter service mode. See Systems Operation, "Service Mode" for more information.Instrument Panel
The engine control switch (ECS) (16) determines the status of the control panel. If the ECS is in the AUTO position the generator can be remotely controlled and remotely monitored with a Customer Communication Module. See Systems Operation, "Customer Communication Module". The GSC+ allows the engine to start whenever the remote initiating contact is closed. The engine starts and the engine runs while the ECS is in the MANUAL START position. If the ECS is placed in the COOLDOWN/STOP position the engine shuts down after a cooldown period. If the ECS is placed in the OFF/RESET position the engine shuts down immediately and any fault indicators are reset. If the ESPB is pushed in the dedicated emergency stop indicator will not be reset.If the red emergency stop push button (ESPB) (14) is pressed, the fuel is shut off. The operator must turn the ESPB clockwise until the ESPB releases in order to restart the engine. Next turn the ECS to OFF/RESET and then turn the ECS to the MANUAL START.The voltage adjust rheostat (VAR) (8) connects to the voltage regulator and the VAR is used to adjust generator voltage to the desired level. The VAR is used in place of the voltage level rheostat. The voltage level rheostat is located on the assembly for the generator voltage regulator.The optional speed adjust potentiometer (SP) (6) is used to raise


Parts bearing JOHNSON:

0314693
 
0314693 BEARING
100ESL71A, 100ESL72R, 100ML79S, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL78C, 175TL79R, 200TL78
0385503
BEARING, Ball
0385503 BEARING, Ball
100ML79S, 115EL77S, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 23
0385482
BEARING, Wrist pin
0385482 BEARING, Wrist pin
115ESL73M, 115ESL74B, 115ESL75E, 135ESL73M, 135ESL74B, 135ESL75E, 200TL76S, 55E76E, 70EL76D, 75ELR76D, 85EL76D, 85ESL73M, 85ESL74B, 85ESL75E
0387139
 
0387139 BEARING SET,Conn.rod
115ESL75E, 135ESL75E, 200TL76S, 85EL76D, 85ESL75E, J100WMLCDR, J100WTLCUA, J110MLCDC, J115MLCOS, J90MLCDC, J90MLCOS
0387817
BEARING,Pinion
0387817 BEARING,Pinion
150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLS
0387245
 
0387245 BEARING HOUSING & SEAL
150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, J115MLCNB, J115MLCTE, J140MLCNB, J140MLCTE, J150STLCTE, J150TLCIA, J150TLCNM, J150TLCSF, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCSA, J175TLC
0386319
 
0386319 BEARING ASSY.,Forward gear
175TL77S, 200TL76S, 200TL77C
0389039
BEARING ASSY
0389039 BEARING ASSY
150TL78S, 175TL78C, 200TL78R, 235TL78R, BJ130TLEDM, BJ130TLEUB, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ200CXEDR, BJ200CXEEB, BJ200CXSSE, BJ200PLSIF, BJ225CXEEC, BJ225CXSSR, BJ225P
Back to top