0324661 JOHNSON BLADDER,Fuel pump


0324661 BLADDER,Fuel pump JOHNSON BJ3REDS, BJ4BREDS, BJ4BREUC, J3REIA, J3RENM, J3REOD, J3RERE, J3RETB, J3REUC, J4BRECRJ, J4RDHCDE, J4RDHCUD, J4REEA, J4REIA, J4RENM, J4REOD, J4RERE, J4RETB, J4RLSIB, J4RLSSM, J5RCIC, J5RCSS, J5RHCNR, J5RHCTA, J8RCIC, J8RCNR, J8RCSS, J8RCTA BLADDER

Buy BLADDER,Fuel pump 0324661 JOHNSON genuine, new aftermarket parts with delivery
Number on catalog scheme: 32
 

BRP JOHNSON entire parts catalog list:

BJ3REDS, SJ3REDS 1996
BJ4BREDS, BJ4BRLEDS, BJ4REDS, BJ4RLEDS, J4REDS, J4RLEDS, SJ4REDS, SJ4RLEDS 1996
BJ4BREUC, BJ4BRLEUC, J4REUC, J4RLEUC 1997
J3REIA 1991
J3RENM 1992
J3REOD 1995
J3RERE 1994
J3RETB 1993
J3REUC 1997
J4BRECRJ, J4BRLECRJ 1998
J4RDHCDE 1986
J4RDHCUD, J4RDHLCUD 1987
J4REEA, J4RLEEA 1999
J4REIA, J4RLEIA 1991
J4RENM, J4RLENM 1992
J4REOD, J4RLEOD 1995
J4RERE, J4RLERE 1994
J4RETB, J4RLETB 1993
J4RLSIB, J4RSIB 2001
J4RLSSM, J4RSSM 2000
J5RCIC, J5RHCIC, J5RHLCIC, J5RLCIC 1981
J5RCSS, J5RHCSS, J5RHLCSS, J5RLCSS 1980
J5RHCNR, J5RHLCNR 1982
J5RHCTA, J5RHLCTA 1983
J8RCIC, J8RLCIC 1981
J8RCNR, J8RLCNR, J8SRLCNR 1982
J8RCSS, J8RLCSS 1980
J8RCTA, J8RLCTA, J8SRLCTA 1983

Information:


Sulfuric Acid Burn Hazard may cause serious personal injury or death.The exhaust gas cooler may contain a small amount of sulfuric acid. The use of fuel with sulfur levels greater than 15 ppm may increase the amount of sulfuric acid formed. The sulfuric acid may spill from the cooler during service of the engine. The sulfuric acid will burn the eyes, skin and clothing on contact. Always wear the appropriate personal protective equipment (PPE) that is noted on a material safety data sheet (MSDS) for sulfuric acid. Always follow the directions for first aid that are noted on a material safety data sheet (MSDS) for sulfuric acid.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Illustration 1 g06102111
Typical example
Illustration 2 g06102122
Typical example
Disconnect harness assembly (1) from exhaust gas recirculation valve (2).
Remove bolts (3) from tube assembly (5). Support the exhaust gas recirculation valve as bolts (3) are removed.
Remove exhaust gas recirculation valve (2) from the inlet manifold.
Remove gasket (4) (not shown) and gasket (9) (not shown).
If necessary, remove bolts (6) and remove tube assembly (5) from exhaust cooler (NRS) (7) and exhaust gas recirculation valve (2).
Remove gasket (8) (not shown).Installation Procedure
Table 1
Required Tools
Tool Part Number Part Description Qty
A 4C-5598 Anti-Seize Compound 1
Sulfuric Acid Burn Hazard may cause serious personal injury or death.The exhaust gas cooler may contain a small amount of sulfuric acid. The use of fuel with sulfur levels greater than 15 ppm may increase the amount of sulfuric acid formed. The sulfuric acid may spill from the cooler during service of the engine. The sulfuric acid will burn the eyes, skin and clothing on contact. Always wear the appropriate personal protective equipment (PPE) that is noted on a material safety data sheet (MSDS) for sulfuric acid. Always follow the directions for first aid that are noted on a material safety data sheet (MSDS) for sulfuric acid.
Keep all parts clean from contaminants.Contaminants may cause rapid wear and shortened component life.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Dispose of all fluids according to local regulations and mandates.
Ensure that all components are clean and free from wear and damage. If necessary, replace any components that are worn or damaged.
Inspect the airways of the exhaust gas recirculation valve for deposits and debris. Use a suitable clean lint free cloth with a suitable engine cleaner to clean the deposits and debris out of the exhaust gas recirculation valve.
Illustration 3 g06102111
Typical example
Illustration 4 g06102122
Typical example
Clean the gasket surface's of exhaust gas recirculation valve (2).
Ensure that tube assembly (5) is clean and free from restriction, wear, and damage. If necessary, replace the tube assembly.
Position a new gasket (9) (not shown) onto exhaust gas recirculation valve (2). Ensure that the gasket is correctly orientated.
Position exhaust gas recirculation valve (2) onto the inlet manifold.
Position a new gasket (4) (not shown) between tube assembly (5) and exhaust gas recirculation valve (2).
Apply Tooling (A) to the threads of bolts (3).
Position tube assembly (5) onto exhaust cooler (NRS) (7).
Loosely install bolts (3) to tube assembly (5).
Position a new gasket (8) (not shown) onto tube assembly (5).
Position tube assembly (1) onto exhaust cooler (NRS) (7).
Apply Tooling (A) to the threads bolts (6).
Loosely install bolts (6) to tube assembly (5).
Tighten bolts (3) and bolts (6) to a torque of 25 N m (221 lb in). Ensure that tube assembly (5) is not strained as the bolts are tightened.
Connect harness assembly (1) to exhaust gas recirculation valve (2).
After replacement of the exh


Back to top