5030398 JOHNSON BOLT, Bearing housing


5030398 BOLT, Bearing housing JOHNSON BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S BOLT
5030398 BOLT, Bearing housing JOHNSON
Rating:
73

Buy BOLT, Bearing housing 5030398 JOHNSON genuine, new aftermarket parts with delivery

You can buy parts:

As an associate, we earn commssions on qualifying purchases through the links below
$11.39
 

13-09-2024

CN: Marine Parts Manufac
Outboard Engine 90105-08M02 97095-08025 97395-08025 90105-081A7 97075-08025 Bolt with Washer for Yamaha, 827207 8878272 for Mercury, 09117-08057 08064 08110 for Suzuki, 5030398 for Johnson Evinrude
SouthMarine fit Yamaha 90105-08M02 97095-08025 97395-08025 90105-081A7 97075-08025 97080-08025 98902-08025 98903-08025 || fit Mercury: 827207, 8878272 || fit Suzuki: 09117-08057, 09117-08064, 09117-08110, 09117-08110-000 || fit Johnson Evinrude OEM: 5030398 || Fit Yamaha F9.9 (1998-2008) - F13.5 (2002-2007) - F15 (1998-2007) F20 & F50 & F60 || Material: Stainless Steel || If you are unsure, please provide your engine serial number.
Number on catalog scheme: 35
 

BRP JOHNSON entire parts catalog list:

BJ115L4SDA, BJ115PX4SDA, J115PL4SDA, J115PX4SDA 2006
BJ115L4SRC, BJ115X4SRC, J115PL4SRC, J115PX4SRC 2004
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140CX4STS 2003
J140PL4SOR 2005
J140PL4STS, J140PX4STS 2003
J140PX4SOR 2005
J25PL4SOC, J25TEL4SOC 2005
J25PL4SRS 2004
J30PL4SDR 2006
J30PL4SOC, J30TEL4SOC 2005
J30PL4SRS 2004
J30PL4SUA 2007
J30TEL4SDR 2006
J30TEL4SUA 2007
J60PL4SNF 2002
J70FLTLECS 1998
J70PL4SNF 2002
J90PL4SOR, J90PX4SOR 2005

Information:


Illustration 1 g00880157
Test Step 1. Inspect Electrical Connectors and Wiring
Turn the keyswitch to the OFF/RESET position.
Thoroughly inspect the J1/P1 ECM connector, the J3/P3 machine connector, and all other connectors in the wiring harness. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.Expected Result:All connectors, pins, and sockets should be completely inserted and coupled. The harness and wiring should be free of corrosion, abrasion, and pinch points. All connections and grounds should be tight and free of corrosion.Results:
OK - Proceed to Test Step 2.
Not OK - Repair: Repair the circuit.Verify that the repair eliminates the problem.STOPTest Step 2. Check the Resistance through the Solenoid
Turn the keyswitch to the OFF/RESET position.
Disconnect the push/pull solenoid for the variable pitch fan.
Measure the resistance between J160:1 (Push Solenoid) and J160:2 (Digital Return).
Measure the resistance between J160:4 (Pull Solenoid) and J160:3 (Digital Return).Expected Result:Resistance should be 25 5 Ohms.Results:
OK - The push/pull solenoid for the variable pitch fan has the correct resistance. Proceed to Test Step 3.
Not OK - The push/pull solenoid for the variable pitch fan is faulty.Repair: Install a new push/pull solenoid for the variable pitch fan.Verify that the repair eliminates the problem.STOPTest Step 3. Check the Status of the Manual Purge Switch onCaterpillar Electronic Technician (Cat ET)
Connect Cat ET to the service tool connector.
Turn the keyswitch to the ON position.
Observe the status for "Engine Fan Manual Purge Switch" on Cat ET while you operate the switch.
Turn the keyswitch to the OFF/RESET position.Expected Result:The status of the switch should be "On" when the switch is depressed. The status should read "Off" when the switch is released.Results:
OK - The manual purge switch is working properly. Proceed to Test Step 5.
Not OK - The ECM does not recognize the input from the manual purge switch. Proceed to Test Step 4.Test Step 4. Check the Manual Purge Switch
Turn the keyswitch to the OFF/RESET position.
Disconnect the J161/P161 manual purge switch connector.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the released position.
Measure continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) with the manual purge switch in the depressed position.Expected Result:There should be no continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the released position. There should be continuity between P161:A (Manual Purge Switch) and P161:B (Digital Return) when the switch is in the depressed position.Results:
OK - There is no continuity when the switch is in the released position. There is continuity when the switch is in the depressed position. Proceed to Test Step 5.
Not OK - There is a problem with the manual purge switch.Repair: Replace the manual purge switch with a new switch.Verify that the repair eliminates the problem.STOPTest Step 5. Check for Shorts in the Harness for the Variable Pitch Fan
Illustration 2 g00880165
Disconnect the J1/P1 ECM connector.
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between P1:45 (Manual Purge Switch) and chassis ground.
Measure the resistance between P1:13 (Pull Solenoid) and chassis ground.
Measure the resistance between P1:10 (Push Solenoid) and chassis ground.
Measure the resistance between P1:45 (Manual Purge Switch) and P1:5 (Digital Return).
Measure the resistance between P1:13 (Pull Solenoid) and P1:5 (Digital Return).
Measure the resistance between P1:10 (Push Solenoid) and P1:5 (Digital Return).
Measure the resistance between P1:45 (Manual Purge Switch) and P1:13 (Pull Solenoid).
Measure the resistance between P1:45 (Manual Purge Switch) and P1:10 (Push Solenoid).
Measure the resistance between P1:13 (Pull Solenoid) and P1:10 (Push Solenoid).Expected Result:The resistance for each measurement should be greater than 20,000 Ohms.Results:
OK - There are no shorts in the harness. Proceed to Test Step 6.
Not OK - There is a short between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.STOPTest Step 6. Check for Open Circuits in the Harness for the Variable Pitch Fan
Illustration 3 g00880165
Turn the keyswitch to the OFF/RESET position and disconnect the J1/P1 ECM connector.
Use a suitable piece of wire to short P1:45 (Manual Purge Switch) and P1:5 (Digital Return).
Disconnect the J160/P160 push/pull solenoid connector.
Disconnect the J161/P161 manual purge switch connector.
Measure the resistance between J161:B (Manual Purge Switch) and J161:C (Digital Return).
Use a suitable piece of wire to short P1:13 (Pull Solenoid) and P1:5 (Digital Return).
Measure the resistance between P160:4 (Pull Solenoid) and P160:3 (Digital Return).
Use a suitable piece of wire to short P1:10 (Push Solenoid) and P1:5 (Digital Return).
Measure the resistance between P160:1 (Push Solenoid) and P160:2 (Digital Return).
Remove all shorts and reconnect all connectors.Expected Result:The resistance should be less than 10 Ohms.Results:
OK - The wiring harness for the variable pitch fan is operating correctly. The ECM is not sending the correct signal to the push/pull solenoid for the variable pitch fan.Repair: Verify your results. Replace the ECM. Refer to Troubleshooting, "Replacing the ECM" before replacing the ECM.Verify that the repair eliminates the problem.STOP
Not OK - There is an open circuit between the ECM and the push/pull solenoid and/or the manual purge switch.Repair: Repair the circuit.Verify that the repair eliminates the problem.STOP


Parts bolt JOHNSON:

5030037
 
5030037 BOLT, Anode
BJ115L4SDA, BJ140CX4DR, BJ140L4SDR, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ
5030989
 
5030989 BOLT, Plate
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR,
5030987
 
5030987 BOLT
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030402
BOLT, Front, mount
5030402 BOLT, Front, mount
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4S
5030782
5031215
 
5031215 BOLT (8X16mm)
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC
5033638
 
5033638 *BOLT, CAM SHAFT HOUSING
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J200CX4S
5034123
 
5034123 BOLT
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4STS, J140PX4SOR, J90PL4SOR
Back to top