Illustration 1 g00488507
System Schematic For Run Relay (RR)The contacts for the run relay (RR) are available for use by the customer. The RR is located within the relay module. The GSC+ activates the RR during engine cranking and running.Note: Whenever the GSC+ activates the RR, "K5" is shown on the lower display. "K5" is also shown on the lower display when the GSC+ attempts to activate the crank terminate relay. When the RR is not activated, "K5" is not shown.ProcedureThe possible cause of this diagnostic code is an open coil or a shorted coil of the RR.The following response is the system response to this fault while the RR is activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is deactivated. Also, any equipment that is connected to RM-23 is activated.The following response is the system response to this fault while the RR is not activated:
If a CID 445 occurs, then any equipment that is connected to RM-24 is not activated. Also, any equipment that is connected to RM-23 remains activated.The GSC+ treats this diagnostic code as an alarm fault. Active alarm faults are shown on the display when the alarm codes key is pressed. The active alarm faults are shown when the ECS is in any position except OFF/RESET. Clear the diagnostic code from the fault log after troubleshooting is complete.
Check the status of the diagnostic code (Active/Inactive).
Turn the ECS to OFF/RESET and then turn the ECS to STOP.
Press the alarm codes key.
Observe the upper display. Check that a CID 445 FMI 12 is showing.
If this diagnostic code is not showing, enter the service mode. View the fault log (OP1). Check that the diagnostic code is showing. Expected Result: A CID 445 FMI 12 is showing as a active fault or an inactive fault. Results:
OK: A CID 445 FMI 12 has not occurred. The fault is NOT active and the fault is NOT inactive. STOP.
NOT OK: A CID 445 FMI 12 is active or inactive. Proceed to 2.
Check internal cable of relay module. Note: Only open the relay module in a dry environment. If the inspection takes more than twenty minutes replace the desiccant bag in the GSC+ housing. See Testing And Adjusting, "Relay Module Replace".
Turn the ECS to OFF/RESET.
Temporarily, remove the relay module from the GSC+. See Testing And Adjusting, "Relay Module - Replace".
Check the cable that attaches the relay module to the GSC+. Expected Result: The cable should be firmly seated in the connector. The clamp should be in place. The cable should not be damaged. Results:
OK: Reassemble the relay module to the GSC+. Proceed to 3.
NOT OK: Replace the connector clamp if the clamp is missing. If the cable is damaged, replace the GSC+. STOP.
Perform a functional check for the RR.
Turn the ECS to OFF/RESET.
Disconnect all wires from RM-24 of the relay module. Remove the fuse "F4" from the relay module.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be greater than 5000 ohms.
Turn the ECS to the START position. Make sure that "K5" is showing on the lower display.
At the relay module, measure the resistance from RM-24 to RM-8. Resistance should be less than 5 ohms.Expected Result: For 3.c, the resistance should be greater than 5000 ohms. For 3.e, the resistance should be less than 5 ohms.Results:
OK: There was probably a poor connection and this procedure corrected the poor connection. Check the electrical connectors, terminals and wiring. See Testing And Adjusting, "Electrical Connector - Inspect". STOP.
NOT OK: Either one of the resistance measurements are NOT correct. The relay module is faulty. Replace the relay module. See Testing And Adjusting, "Relay Module - Replace". STOP.


Parts bolt JOHNSON:

5030037
 
5030037 BOLT, Anode
BJ115L4SDA, BJ140CX4DR, BJ140L4SDR, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ
5030989
 
5030989 BOLT, Plate
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR,
5030609
BOLT, Cylinder head
5030609 BOLT, Cylinder head
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030987
 
5030987 BOLT
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030413
BOLT, Anode
5030413 BOLT, Anode
BJ115L4SRC, BJ115L4STS, BJ140CX4SRS, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SRC, BJ90PL4STS, J115PL4S
5030402
BOLT, Front, mount
5030402 BOLT, Front, mount
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4S
5031121
 
5031121 BOLT, Bracket, cables
BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J40PL4SNF, J40PL
5030782
Back to top