5030994 BOLT, Tensioner JOHNSON
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS
BOLT
Price: query
Rating:
Compatible models:
BJ115L4SDA
BJ115L4SRC
BJ115L4STS
BJ140CX4DR
BJ140CX4SRS
BJ140L4SDR
BJ140PL4SRS
BJ200CX4DC
BJ200X4SDC
BJ225CX4DC
BJ225X4SDC
BJ25E4SDS
BJ25E4SUC
BJ25TE4SDS
BJ25TE4SUC
BJ40PL4SDR
BJ40PL4SOC
BJ40PL4SRS
BJ50PL4SDR
BJ50PL4SOC
BJ50PL4SRS
BJ60PL4SDM
BJ60PL4SOA
BJ60PL4SRR
BJ60PL4STC
BJ70PL4SDM
BJ70PL4SOA
BJ70PL4SRR
BJ70PL4STC
BJ90PL4SDA
BJ90PL4SRC
BJ90PL4STS
J10BL4SUM
J10EL4SDA
J10EL4SOR
J10EL4SRC
J10R4SDM
J10R4SNF
J10R4SR
J10R4SUB
J10RL4SDM
J10TBL4SDE
J10TBL4SUD
J10TE4SDM
J115PL4SOR
J140CX4SOR
J140CX4STS
J140PL4SOR
J140PL4STS
J140PX4SOR
J15EL4SDC
J15EL4SOS
J15EL4SUR
J15R4SDM
J15R4SNF
J15R4SR
J15R4SUB
J15RL4SDM
J15RL4SR
J15TE4SDM
J15TE4SUB
J200CX4SOC
J200CX4SRS
J200PX4SOC
J200PX4SRS
J225CX4SOC
J225CX4SRS
J225PX4SOC
J225PX4SRS
J40PL4SNF
J40PL4STC
J50PL4SNF
J50PL4STC
J60PL4SNF
J70FLTLECS
J70PL4SNF
J90PL4SOR
JOHNSON
BRP JOHNSON entire parts catalog list:
- CYLINDER HEAD » 5030994
- STARTER MOTOR
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ140CX4DR, J140CX4SDA 2006
BJ140CX4SRS, J140CX4SRC 2004
BJ140L4SDR, BJ140X4SDR, J140PL4SDA, J140PX4SDA 2006
BJ140PL4SRS, BJ140PX4SRS, J140PL4SRC, J140PX4SRS 2004
BJ200CX4DC 2006
BJ200X4SDC 2006
BJ225CX4DC 2006
BJ225X4SDC 2006
BJ25E4SDS, BJ25EL4SDS, J25E4SDC, J25EL4SDC 2006
BJ25E4SUC, BJ25EL4SUC, J25E4SUR, J25EL4SUR 2007
BJ25TE4SDS, BJ25TEL4SDS, J25TE4SDC, J25TEL4SDC 2006
BJ25TE4SUC, BJ25TL4SUC, J25TE4SUR, J25TEL4SUR 2007
BJ40PL4SDR, J40PL4SDE 2006
BJ40PL4SOC, J40PL4SOB 2005
BJ40PL4SRS, J40PL4SRM 2004
BJ50PL4SDR, J50PL4SDE 2006
BJ50PL4SOC, J50PL4SOB 2005
BJ50PL4SRS, J50PL4SRM 2004
BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J10BL4SUM, J10EL4SUM 2007
J10EL4SDA 2006
J10EL4SOR, J10R4SOA, J10RL4SOA, J10TBL4SOB, J10TE4SOA, J10TEL4SOA 2005
J10EL4SRC 2004
J10R4SDM 2006
J10R4SNF, J10RL4SNF, J10TE4SNF, J10TEL4SNF 2002
J10R4SR, J10RL4SR, J10TBL4SR, J10TE4SR, J10TEL4SR 2004
J10R4SUB, J10RL4SUB 2007
J10RL4SDM 2006
J10TBL4SDE 2006
J10TBL4SUD, J10TE4SUB, J10TEL4SUB 2007
J10TE4SDM, J10TEL4SDM 2006
J115PL4SOR, J115PX4SOR 2005
J140CX4SOR 2005
J140CX4STS 2003
J140PL4SOR 2005
J140PL4STS, J140PX4STS 2003
J140PX4SOR 2005
J15EL4SDC 2006
J15EL4SOS, J15R4SOA, J15RL4SOA, J15TE4SOA, J15TEL4SOA 2005
J15EL4SUR 2007
J15R4SDM 2006
J15R4SNF, J15RL4SNF, J15TE4SNF, J15TEL4SNF 2002
J15R4SR, J15TE4SR, J15TEL4SR 2004
J15R4SUB, J15RL4SUB 2007
J15RL4SDM 2006
J15RL4SR 2004
Information:
Illustration 1 g00955359
Schematic
Illustration 2 g00955360
P2 ECM connectorTest Step 1. Verify all Active Diagnostic Codes
Connect the electronic service tool to the service tool connector.
Turn the keyswitch to the ON position. Wait at least 15 seconds for activation of the diagnostic codes.
Monitor the "Active Diagnostic Codes" screen on the electronic service tool.Expected Result:There is an active diagnostic code for one or more of the temperature sensors.Results:
Yes - There is an active diagnostic code for one or more of the temperature sensors. Proceed to Test Step 2.
No - There are no active diagnostic codes for the temperature sensors.Repair: If there are logged diagnostic codes for one or more of the temperature sensors and the engine is not running properly, refer to Troubleshooting, "Troubleshooting without a Diagnostic Code". If the engine is running properly at this time, an intermittent condition may be causing the logged codes. Refer to Troubleshooting, "Electrical Connectors - Inspect". Stop.Test Step 2. Inspect Electrical Connectors and Wiring
Thoroughly inspect the J1/P1 ECM connector, the J2/P2 ECM connector, the suspect sensor connector, and any other connectors in the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Perform a 45 N (10 lb) pull test on each of the wires in the sensor connector and the ECM connector that are associated with the active diagnostic code.
Verify that the latch tab of the connector is properly latched.
Check the ECM connector (allen head screw) for the proper torque of 6.0 N m (55 lb in).
Check the harness and wiring for abrasions and for pinch points from the sensor to the ECM.Expected Result:All connectors, pins, and sockets should be completely coupled and/or inserted. The harness and wiring should be free of corrosion, abrasion, and pinch points.Results:
OK - Proceed to Test Step 3.
Not OK - Repair: Repair the connectors or wiring and/or replace the connectors or wiring. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled.Verify that the repair eliminates the problem. Stop.Test Step 3. Verify that the Diagnostic Code is Still Active
Turn the keyswitch to the ON position. Wait at least 15 seconds for activation of the diagnostic codes.
Access the "Active Diagnostic Codes" screen on the electronic service tool and check for active diagnostic codes.
Determine if the problem is related to an open circuit diagnostic code or a short circuit diagnostic code.Expected Result:A short circuit diagnostic code or an open circuit diagnostic code is active.Results:
Short Circuit - A short circuit diagnostic code is active at this time. Proceed to Test Step 4.
Open Circuit - An open circuit diagnostic code is active at this time. Proceed to Test Step 6.
No Active Diagnostic Codes - There is a problem in the connectors and/or the wiring.Repair: Carefully reinspect the connectors and wiring. The diagnostic code will probably reoccur. Refer to Troubleshooting, "Electrical Connectors - Inspect" for additional information. Stop.Test Step 4. Disconnect the Sensor in Order to Create an Open Circuit
Turn the keyswitch to the OFF/RESET position.
Disconnect the connector to the sensor with the short circuit diagnostic code.
Turn the keyswitch to the ON position. Wait at least 15 seconds for activation of the diagnostic codes.
Access the "Active Diagnostic Codes" screen on the electronic service tool and check for an active open circuit diagnostic code for the suspect sensor.Expected Result:An open circuit diagnostic code is now active for the disconnected sensor.Results:
OK - A short circuit diagnostic code was active before disconnecting the sensor. An open circuit diagnostic code became active after disconnecting the sensor. Proceed to Test Step 5.
Not OK - There is a short circuit between the sensor harness connector and the ECM. Leave the sensor disconnected. Proceed to Test Step 7.Test Step 5. Determine if the Short Circuit is in the Connector or in the Sensor
Thoroughly inspect the connector for moisture.
Inspect the seals and reconnect the sensor.
If the short circuit diagnostic code reappears, the sensor is the problem.
Temporarily connect a new sensor to the harness, but do not install the new sensor in the engine.
Check for a short circuit diagnostic code while the new sensor is connected.Expected Result:The short circuit diagnostic code is not present when a new sensor is connected.Results:
OK - The suspect sensor had an internal short.Repair: Permanently install the new sensor and clear any logged diagnostic codes.Verify that the repair eliminates the problem. Stop.
Not OK - The connector is shorted.Repair: Repair the connector. Stop.Test Step 6. Short the Sensor Connector
Turn the keyswitch to the ON position.
Unplug the suspect sensor.Note: Monitor the "Active Diagnostic Codes" screen on the electronic service tool before installing the jumper wire and after installing the jumper wire.
Install a jumper wire with Deutsch sockets on each end between the terminals on the plug for the suspect sensor. Wait at least 15 seconds for activation of the short circuit diagnostic code.
Remove the jumper wire.Expected Result:A short circuit diagnostic code is active when the jumper wire is installed. An open circuit diagnostic code is active when the jumper wire is removed.Results:
OK - The engine harness and the ECM are OK.Repair: Perform the following repair:
Temporarily reconnect the suspect sensor.
If the diagnostic code remains active, replace the sensor.
Verify that the repair eliminates the problem.
Clear all logged diagnostic codes. Stop.
Not OK - The open circuit diagnostic code remains active with the jumper in place. There appears to be an open circuit between the ECM and the sensor. Proceed to Test Step 7.Test Step 7. Check the Operation of the ECM by Creating Open And Short Circuits at the ECM Connector
Turn the keyswitch to the OFF/RESET position.
Disconnect the P2 ECM connector. Thoroughly inspect both halves of the connector for signs of corrosion and/or moisture.
Reconnect the ECM connector.
Turn the keyswitch to the ON position. Monitor the "Active Diagnostic Code" screen on the electronic service tool. Wait at least 15 seconds for activation of the code.An open circuit diagnostic code should be active for the suspect sensor. Note the sensor that has the open circuit diagnostic code.
Remove the signal wire and the return wire for the suspect sensor from the P2 ECM connector.Note: Active open circuit diagnostic codes will be
Parts bolt JOHNSON:
5030037
5030037 BOLT, Anode
BJ115L4SDA, BJ140CX4DR, BJ140L4SDR, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ
5030989
5030989 BOLT, Plate
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR,
5030987
5030987 BOLT
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J25PL4SOC, J25PL4SRS, J30PL4SDR, J30PL4SOC, J30PL4SRS, J30PL4SUA, J30TEL4SDR, J30TEL4SUA, J60PL4SNF, J70FLTLECS, J70PL4SNF
5030402
5030402 BOLT, Front, mount
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4S
5030782
5031819
5031819 BOLT
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5031817
5031817 BOLT (6X17mm)
J10BL4SUM, J10EL4SDA, J10EL4SOR, J10EL4SRC, J10R4SDM, J10R4SNF, J10R4SR, J10R4STC, J10R4SUB, J10RL4SDM, J10TBL4SDE, J10TBL4SUD, J10TE4SDM, J15EL4SDC, J15EL4SOS, J15EL4SUR, J15R4SDM, J15R4SNF, J15R4SR, J15R4STC, J15R4SUB, J15RL4SDM, J15RL4SR, J15TE4SD
5032676
5032676 BOLT, LOWER MOUNT (12X164mm)
BJ40PL4SRS, BJ50PL4SRS, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC