5032644 BOLT JOHNSON
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J60PL4SNF, J70PL4SNF, J90PL4SOR
BOLT
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- TRIM MOTOR » 5032644
BJ115L4STS, BJ115X4STS, J115PL4STS, J115PX4STS 2003
BJ60PL4SDM, J60PL4SDM 2006
BJ60PL4SOA, J60PL4SOA 2005
BJ60PL4SRR, J60PL4SRR 2004
BJ60PL4STC, J60PL4STC 2003
BJ70PL4SDM, J70PL4SDM 2006
BJ70PL4SOA, J70PL4SOA 2005
BJ70PL4SRR, J70PL4SRR 2004
BJ70PL4STC, J70PL4STC 2003
BJ90PL4SDA, BJ90PX4SDA, J90PL4SDA, J90PX4SDA 2006
BJ90PL4SRC, BJ90PX4SRC, J90PL4SRC, J90PX4SRC 2004
BJ90PL4STS, BJ90PX4STS, J90PL4STS, J90PX4STS 2003
J115PL4SOR, J115PX4SOR 2005
J60PL4SNF 2002
J70PL4SNF 2002
J90PL4SOR, J90PX4SOR 2005
Information:
#0063dc;"class="show_hide div_show_hide aslink" data-element=".content_table_87654321">
Table 1
Diagnostic Codes for the Active Analog Sensors
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
100-3 100-3 Engine Oil Pressure : Voltage Above Normal The Electronic Control Module (ECM) detects the following conditions:
The signal voltage from the engine oil pressure sensor is greater than 4.8 VDC for more than 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code. The ECM will set data for engine oil pressure to the default value. The default engine oil pressure is 600 kPa (87 psi). The electronic service tool will display "Voltage Above Normal" on the status screens.
100-4 100-4 Engine Oil Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the engine oil pressure sensor is less than 0.2 VDC for more than 8 seconds.
The ECM has been powered for at least 2 seconds.
The warning lamp will come on. The ECM will log the diagnostic code. The ECM will set data for the engine oil pressure to the default value. The default engine oil pressure is 600 kPa (87 psi). The electronic service tool will display "Voltage Below Normal" on the status screens.
108-3 3528-3 Barometric Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the barometric pressure sensor is greater than 4.8 VDC for at least 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code.
108-4 3528-4 Barometric Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the barometric pressure sensor is less than 0.2 VDC for at least 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code.
157-3 1797-3 Engine Injector Metering Rail #1 Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the fuel rail pressure sensor is more than 4.7 VDC for 0.6 seconds.
The warning lamp will flash. The ECM will log the diagnostic code. The electronic service tool will display "70000 kPa" next to "Desired Fuel Rail Pressure" and "Actual Fuel Rail Pressure" on the status screens.
The engine will be derated.
157-4 1797-4 Engine Injector Metering Rail #1 Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the fuel rail pressure sensor is less than 0.67 VDC for 0.6 seconds.
The warning lamp will flash. The ECM will log the diagnostic code.
The electronic service tool will display "70000 kPa" next to "Desired Fuel Rail Pressure" and "Actual Fuel Rail Pressure" on the status screens.
The engine will be derated.
411-3 3387-3 Engine Exhaust Gas Recirculation Differential Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the NOx Reduction System (NRS) differential pressure sensor is more than 4.8 VDC.
The ECM has been powered for at least 0.24 seconds.
The warning light will come on. The ECM will log the diagnostic code.
411-4 3387-4 Engine Exhaust Gas Recirculation Differential Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the NRS differential pressure sensor is less than 0.2 VDC.
The ECM has been powered for at least 0.24 seconds.
The warning light will come on. The ECM will log the diagnostic code.
3241-3 535-3 Exhaust Gas Temperature 1 : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the ARD flame detection temperature sensor is greater than 4.7 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3241-4 535-4 Exhaust Gas Temperature 1 : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the ARD flame detection temperature sensor is less than 0.3 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3242-3 2452-3 Particulate Trap Intake Gas Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the DPF inlet temperature sensor is greater than 4.7 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3242-4 2452-4 Particulate Trap Intake Gas Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the DPF inlet temperature sensor is less than 0.3 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3358-3 3385-3 Engine Exhaust Gas Recirculation Inlet Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the NRS inlet pressure sensor is more than 4.8 VDC for 0.12 seconds.
The ECM has been powered for 2 seconds.
The warning light will come on. The ECM will log the diagnostic code.
The ECM will set data for the NRS inlet pressure to the default value.
Table 1
Diagnostic Codes for the Active Analog Sensors
J1939 Code CDL Code Code Description
(code descriptions may vary) Comments
100-3 100-3 Engine Oil Pressure : Voltage Above Normal The Electronic Control Module (ECM) detects the following conditions:
The signal voltage from the engine oil pressure sensor is greater than 4.8 VDC for more than 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code. The ECM will set data for engine oil pressure to the default value. The default engine oil pressure is 600 kPa (87 psi). The electronic service tool will display "Voltage Above Normal" on the status screens.
100-4 100-4 Engine Oil Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage from the engine oil pressure sensor is less than 0.2 VDC for more than 8 seconds.
The ECM has been powered for at least 2 seconds.
The warning lamp will come on. The ECM will log the diagnostic code. The ECM will set data for the engine oil pressure to the default value. The default engine oil pressure is 600 kPa (87 psi). The electronic service tool will display "Voltage Below Normal" on the status screens.
108-3 3528-3 Barometric Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the barometric pressure sensor is greater than 4.8 VDC for at least 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code.
108-4 3528-4 Barometric Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the barometric pressure sensor is less than 0.2 VDC for at least 8 seconds.
The warning lamp will come on. The ECM will log the diagnostic code.
157-3 1797-3 Engine Injector Metering Rail #1 Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the fuel rail pressure sensor is more than 4.7 VDC for 0.6 seconds.
The warning lamp will flash. The ECM will log the diagnostic code. The electronic service tool will display "70000 kPa" next to "Desired Fuel Rail Pressure" and "Actual Fuel Rail Pressure" on the status screens.
The engine will be derated.
157-4 1797-4 Engine Injector Metering Rail #1 Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the fuel rail pressure sensor is less than 0.67 VDC for 0.6 seconds.
The warning lamp will flash. The ECM will log the diagnostic code.
The electronic service tool will display "70000 kPa" next to "Desired Fuel Rail Pressure" and "Actual Fuel Rail Pressure" on the status screens.
The engine will be derated.
411-3 3387-3 Engine Exhaust Gas Recirculation Differential Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the NOx Reduction System (NRS) differential pressure sensor is more than 4.8 VDC.
The ECM has been powered for at least 0.24 seconds.
The warning light will come on. The ECM will log the diagnostic code.
411-4 3387-4 Engine Exhaust Gas Recirculation Differential Pressure : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the NRS differential pressure sensor is less than 0.2 VDC.
The ECM has been powered for at least 0.24 seconds.
The warning light will come on. The ECM will log the diagnostic code.
3241-3 535-3 Exhaust Gas Temperature 1 : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the ARD flame detection temperature sensor is greater than 4.7 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3241-4 535-4 Exhaust Gas Temperature 1 : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the ARD flame detection temperature sensor is less than 0.3 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3242-3 2452-3 Particulate Trap Intake Gas Temperature : Voltage Above Normal The ECM detects the following conditions:
The signal voltage for the DPF inlet temperature sensor is greater than 4.7 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3242-4 2452-4 Particulate Trap Intake Gas Temperature : Voltage Below Normal The ECM detects the following conditions:
The signal voltage for the DPF inlet temperature sensor is less than 0.3 VDC for at least 4 seconds.
The ECM has been powered for at least 7 seconds.
If equipped, the warning light will come on. The ECM will log the diagnostic code. The engine will be derated.
If a DPF regeneration is in progress, the process will be stopped. Future regenerations will be prevented while the code is active.
3358-3 3385-3 Engine Exhaust Gas Recirculation Inlet Pressure : Voltage Above Normal The ECM detects the following conditions:
The signal voltage from the NRS inlet pressure sensor is more than 4.8 VDC for 0.12 seconds.
The ECM has been powered for 2 seconds.
The warning light will come on. The ECM will log the diagnostic code.
The ECM will set data for the NRS inlet pressure to the default value.
Parts bolt JOHNSON:
5031001
5031001 BOLT
BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J200CX4SOC, J200CX4SRS, J200PX4SOC, J200PX4SRS, J225CX4SOC, J225CX4SRS, J225PX4SOC, J225PX4SRS, J70FLTLECS
5030990
5030990 BOLT, Cover
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR,
5030400
5030400 BOLT, Gearcase
BJ115L4SRC, BJ115L4STS, BJ140CX4SRS, BJ140PL4SRS, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4STS, J60PL4SNF, J70FLTLECS, J70PL4SNF, J90PL4SOR
5030401
5030401 BOLT, Gearcase
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4S
5030387
5030387 BOLT, Silencer
BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ60PL4STC, BJ70PL4SDM, BJ70PL4SOA, BJ70PL4SRR, BJ70PL4STC, J60PL4SNF, J70FLTLECS, J70PL4SNF
5032668
5032668 BOLT (10X35mm)
BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, J40PL4SNF, J40PL4STC, J50PL4SNF, J50PL4STC, J60PL4SNF, J70PL4SNF
5031821
5031821 BOLT (6X12mm)
BJ115L4SDA, BJ115L4SRC, BJ115L4STS, BJ140CX4DR, BJ140CX4SRS, BJ140L4SDR, BJ140PL4SRS, BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ40PL4SRS, BJ50PL4SRS, BJ90PL4SDA, BJ90PL4SRC, BJ90PL4STS, J115PL4SOR, J140CX4SOR, J140CX4STS, J140PL4SOR, J140PL4S
5034399
5034399 BOLT (8X30mm)
BJ200CX4DC, BJ200X4SDC, BJ225CX4DC, BJ225X4SDC, BJ25E4SDS, BJ25E4SUC, BJ25R4SDS, BJ25R4SUC, BJ25TE4SDS, BJ25TE4SUC, BJ40PL4SDR, BJ40PL4SOC, BJ40PL4SRS, BJ50PL4SDR, BJ50PL4SOC, BJ50PL4SRS, BJ60PL4SDM, BJ60PL4SOA, BJ60PL4SRR, BJ70PL4SDM, BJ70PL4SOA, BJ