Required Tools    
Tool     Part Number     Part Description     Qty    
A     9U-6639     Ratchet Wrench     1    Note: Cleanliness is an important factor. Before the disassembly procedure, the exterior of the component should be thoroughly cleaned. This will help to prevent dirt from entering the internal mechanism.
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.Refer to Special Publication, NENG2500, "Caterpillar Tools and Shop Products Guide" for tools and supplies suitable to collect and contain fluids on Caterpillar products.Dispose of all fluids according to local regulations and mandates.
Note: Put identification marks on all lines, on all hoses, on all wires, and on all tubes for installation purposes. Plug all lines, hoses, and tubes. This helps to prevent fluid loss and this helps to keep contaminants from entering the system.
Personal injury can result from contact with refrigerant.Contact with refrigerant can cause frost bite. Keep face and hands away to help prevent injury.Protective goggles must always be worn when refrigerant lines are opened, even if the gauges indicate the system is empty of refrigerant.Always use precaution when a fitting is removed. Slowly loosen the fitting. If the system is still under pressure, release it slowly in a well ventilated area.Personal injury or death can result from inhaling refrigerant through a lit cigarette.Inhaling air conditioner refrigerant gas through a lit cigarette or other smoking method or inhaling fumes released from a flame contacting air conditioner refrigerant gas, can cause bodily harm or death.Do not smoke when servicing air conditioners or wherever refrigerant gas may be present.Use a certified recovery and recycling cart to properly remove the refrigerant from the air conditioning system.
Open the hood.
Recover the air conditioner refrigerant from the air conditioner system. Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Illustration 1 g00956300
Use Tooling (A) to loosen belt (1) .
Illustration 2 g00956568
Disconnect harness assembly (2) and (3) .
Remove the bolt and plate (5). Disconnect hose assemblies (4) and (6) .
Illustration 3 g00956571
Remove bolts (8). Remove refrigerant compressor (7) .Installation Procedure
Table 2
Required Tools    
Tool     Part Number     Part Description     Qty    
A     9U-6639     Ratchet Wrench     1    Note: Cleanliness is an important factor. Before assembly, all parts should be thoroughly cleaned in cleaning fluid. Allow the parts to air dry. Wiping cloths or rags should not be used to dry parts. Lint may be deposited on the parts which may cause later trouble. Inspect all parts. If any parts are worn or damaged, use new parts for replacement.
Illustration 4 g00956571
Install refrigerant compressor (7). Install bolts (8).
Illustration 5 g00956568
Connect hose assemblies (4) and (6). Install the bolt and plate (5).
Connect harness assembly (2) and (3) .
Illustration 6 g00956300
Use Tooling (A) to tighten belt (1) .
Charge the air conditioner system. The correct charge is 2.5 kg (5.5 lb). Refer to Service Manual, SENR5664, "Air Conditioning and Heating Systems with R-134a Refrigerant" for the correct procedure. Refer to Special Publication, NEDG5065, "Air Conditioning Tools" for the correct tools.
Close the hood.