0337065 BRACKET, Upper to swivel brkt. JOHNSON
J100STLEIE, J100STLEND, J115JLEIE, J115JLEND, J88MSLEIM, J88MSLEIM, J88MSLENB, J88MSLENB
BRACKET
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- TRANSOM BRACKET ASSY. - QUIET RIDER » 0337065
J115JLEIE, J115MLEIE, J115TLAIE, J115TLEIE, J115TXEIE, TJ115TLEIE, VJ115TLAIE, VJ115TLEIE, VJ115TXEIE 1991
J115JLEND, J115MLEND, J115TLAND, J115TLEND, J115TXEND, TJ115TLEND, VJ115TLAND 1992
J88MSLEIM 1991
J88MSLEIM, J90JLEIE, J90TLAIE, J90TLEIE, TJ90TLEIE, VJ90MLEIE, VJ90TLAIE, VJ90TLEIE 1991
J88MSLENB 1992
J88MSLENB, J90JLEND, J90TLAND, J90TLEND, TJ90TLEND, VJ90MLEND, VJ90TLAND, VJ90TLEND 1992
Information:
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionMinimum full load current at 5000 rpm ... 67AMinimum full load current at 2000 rpm ... 29AField current at rated voltage and 27°C (80°F) ... 2.5 to 2.9A(1) Torque for nut ... 102 7 N m (75 5 lb ft)(2) Torque for output terminal ... 13.5 1.3 N m (119.47 11.50 lb in)3T6354 Regulator (Inside Alternator)
Voltage Setting ... No AdjustmentPermissible Voltage Range ... 27 to 29V100-5045 Alternator 24V 50A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 44.6ATorque for the ground terminal nut ... 4.4 1 N m (3 .7 lb ft)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.50 lb in)9G7567 Regulator (Under Alternator Cover). For use with the 100-5045 Alternator
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 27 to 29V100-5046 Alternator 24V 50A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 45ATorque for the ground terminal nut ... 2.25 .25 N m (1.65 .184 lb ft)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.50 lb in)9G7567 Regulator (Under Alternator Cover) For use with the 100-5046 Alternator
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 26.5 to 28.5V3T6352 Alternator 24V 35A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 35A(1) Torque for the ground terminal nut ... 2.25 .25 N m (19.9 2.2 lb in)(2) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(3) Torque for the output terminal nut ... 6.2 .6 N m (54.9 5.3 lb in)3T6354 Regulator (Inside Alternator)
Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V7N9720 Alternator 24V 35A
Typical Example Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 35ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.5 lb in)9G7567 Regulator (Under Alternator Cover). For use with the 7N9720 Alternator.
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 26.5 to 28.5V9G4574 Alternator 24V 35A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 35.6A(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.5 lb in)(3) Torque for the ground terminal nut ... 3.4 to 5.4 N m (31 to 49 lb in)
Voltage Setting ... No AdjustmentPermissible Voltage Range ... 27 to 29V100-5045 Alternator 24V 50A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 44.6ATorque for the ground terminal nut ... 4.4 1 N m (3 .7 lb ft)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.50 lb in)9G7567 Regulator (Under Alternator Cover). For use with the 100-5045 Alternator
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 27 to 29V100-5046 Alternator 24V 50A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 45ATorque for the ground terminal nut ... 2.25 .25 N m (1.65 .184 lb ft)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.50 lb in)9G7567 Regulator (Under Alternator Cover) For use with the 100-5046 Alternator
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 26.5 to 28.5V3T6352 Alternator 24V 35A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 35A(1) Torque for the ground terminal nut ... 2.25 .25 N m (19.9 2.2 lb in)(2) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(3) Torque for the output terminal nut ... 6.2 .6 N m (54.9 5.3 lb in)3T6354 Regulator (Inside Alternator)
Voltage setting ... No adjustmentPermissible voltage range ... 27 to 29V7N9720 Alternator 24V 35A
Typical Example Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... ClockwiseSpeed for testing (rpm) ... 5000Output voltage ... 27.5 1.0VOutput (cold) ... 35ATorque for the ground terminal nut ... 2.1 to 2.8 N m (19 to 25 lb in)(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.5 lb in)9G7567 Regulator (Under Alternator Cover). For use with the 7N9720 Alternator.
Voltage rating ... 28VPolarity ... Negative GroundVoltage setting range ... 26.5 to 28.5V9G4574 Alternator 24V 35A
Load the battery with a carbon pile (4C4911 Battery Load Tester) to get the maximum alternator output.Polarity ... Negative GroundRotation ... Either DirectionSpeed for testing (rpm) ... 5000Output voltage ... 28 1.0VOutput (cold) ... 35.6A(1) Torque for the pulley nut ... 102 7 N m (75 5 lb ft)(2) Torque for the output terminal nut ... 13.5 1.3 N m (119.47 11.5 lb in)(3) Torque for the ground terminal nut ... 3.4 to 5.4 N m (31 to 49 lb in)
Parts bracket JOHNSON:
0125409
0125409 BRACKET
D100WTLM, J100STLCCA, J100STLCEM, J100STLEIE, J100STLESB, J100WTLEIB, J100WTLENE, J100WTLERS, J100WTLESM, J100WTLETD, J100WTLZ, J110MLCCA, J110MLCEM, J115JLEIE, J115MLESB, J120TLAEM, J120TLAIE, J120TLASB, J125ESXESS, J140CXCEC, J140CXEIA, J140CXESR,
0336881
0336881 BRACKET, Cable
BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF, BJ175PLSSC, BJ40EEDS, BJ40EEUC, BJ50BEEDS, BJ50RLEUC, BJ90PLEEB, BJ90PLSID, BJ90PLSSE, BJ90SLE
0336171
0336171 BRACKET, Tilt limit switch
BJ115ELEDR, BJ115ELEUA, BJ115GLECM, BJ115PLEEM, BJ115PLSIE, BJ115PLSSB, BJ115TLEDA, BJ130PLEED, BJ130PLSSS, BJ130TLECE, BJ130TLEDM, BJ130TLEUB, BJ135PLSIF, BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSIF
0337247
0337247 BRACKET, Lower to swivel brkt.
J100STLEIE, J100STLEND, J115JLEIE, J115JLEND, J88MSLEIM, J88MSLEIM, J88MSLENB, J88MSLENB
0337064
0337064 BRACKET, Tilt cylinder
J100STLEIE, J100STLEND, J100STLETS, J115JLEIE, J115JLEND, J115JLETS, J150ELARA, J150ELATG, J175EXARC, J175EXATG, J88MSLEIM, J88MSLEIM, J88MSLENB, J88MSLENB, J88MSLETE, J88MSLETE
0126272
0126272 BRACKET
BJ150ELECD, BJ150ELEDB, BJ150ELEUC, BJ175EXECD, BJ175EXEDB, BJ175EXEUC, BJ175PLEES, BJ175PLSSC, BJ25ARECA, BJ25AREDC, BJ25AREUR, BJ25PL3EEM, BJ25PL3SIE, BJ25PL3SSB, BJ35ARECR, BJ35AREDS, BJ35AREEA, BJ35AREUC, BJ35E3SIE, BJ35E3SSB, BJ50DTLEDC, BJ60ELE
0336991
0336991 BRACKET, Locating, front
BJ115TLEDA, HJ88MSLEDC, HJ88MSLEDC, J100STLEND, J100STLERC, J100STLETS, J100WTLEDR, J100WTLENE, J100WTLEOC, J100WTLERS, J100WTLETD, J100WTLEUA, J112TSLEDR, J112TSLEDR, J112TSLEOC, J112TSLEOC, J112TSLERS, J112TSLERS, J115JKLEOC, J115JKLERS, J115JLEND,
0911229
0911229 BRACKET, Remote control cables
J100STLEND, J100STLETS, J115JLEND, J115JLETS, J88MSLENB, J88MSLENB, J88MSLETE, J88MSLETE