0314003 BUSHING, Spark lever JOHNSON
100ESL71A, 100ESL72R, 115ESL69E, 115ESL70D, 125ESL71C, 125ESL72R, 50ES71S, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, 55ES69A, 60ES70B, 60ES71C, 65ES72S, 65ES73R, 70EL76D, 70EL77S, 70EL78C, 70EL79R, 70ES74M, 70ES75B,
BUSHING
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
100ESL71A
100ESL72R
115ESL69E
115ESL70D
125ESL71C
125ESL72R
50ES71S
50ES72C
50ES73R
50ES74M
50ES75B
50R79C
55E76E
55E77D
55E78S
55E79C
55ES69A
60ES70B
60ES71C
65ES72S
65ES73R
70EL76D
70EL77S
70EL78C
70EL79R
70ES74M
70ES75B
75ELR76D
75ELR77S
75ELR78C
75ELR79R
75ESLR75B
85ESL69E
85ESL70B
85ESL71A
85ESL72R
BJ50DTLEDC
BJ50DTLEUR
BJ60ELEDR
BJ60ELEUA
BJ60TLECM
BJ70ELECB
BJ70ELEDA
BJ70ELEUM
BJ70PLEEE
BJ70PLSIS
BJ70PLSSD
J35AELCDE
J35AELCUD
J40AELCCS
J40ECDE
J40ECOB
J40ECRM
J40ECUD
J40JPLEEC
J40JPLSIA
J40JPLSSR
J45RCE
J45RCEIA
J45RCENM
J45RCESR
J48ESLCCC
J48ESLCUS
J50BECCS
J50BECDE
J50BECIC
J50BECNR
J50BECOB
J50BECRM
J50BECTA
J50BECUD
J50DTLECA
J50DTLEOS
J50ECSR
J55RCIM
J55RLCSA
J55RSLN
J55RWLE
J55RWLEIA
J55RWLENM
J55RWLESR
J60ECIA
J60ECNM
J60ECSR
J60ECTB
J60ELCCR
J60ELCDS
J60ELCEA
J60ELCOD
J60ELCRE
J60ELCUC
J60ELEIB
J60ELENE
J60ELEOC
J60ELERS
J60ELESM
J60ELETD
J60PLEEB
J60PLSID
J60PLSSE
J65WELEES
J65WELSIR
J65WELSSC
J65WMLCDR
J65WMLCOC
J65WMLCUA
J65WMLEIB
J65WMLENE
J65WMLEOC
J65WMLERS
J65WMLESM
J65WMLETD
J65WMLZ
J70ELCCA
J70ELCDC
J70ELCEM
J70ELCIH
J70ELCNB
J70ELCOS
J70ELCRD
J70ELCSA
J70ELCTE
J70ELCUR
J70ELEIE
J70ELEND
J70ELEOR
J70ELERC
J70ELESB
J70ELETS
J75ECCA
J75ECDC
J75ECNB
J75ECOS
J75ECRD
J75ECTE
J75ECUR
J75ERCIH
J75ERCSA
N65WMLM
SJ65WMLD
SJ65WMLM
SJ65WMLZ2
TR-10R
JOHNSON
BRP JOHNSON entire parts catalog list:
- CYLINDER & CRANKCASE » 0314003
115ESL69E, 115ESL69S 1969
115ESL70D 1970
125ESL71C 1971
125ESL72R 1972
50ES71S, 50ESL71S 1971
50ES72C, 50ESL72C, 50R72C, 50RL72C 1972
50ES73R, 50ESL73R, 50R73R, 50RL73R 1973
50ES74M, 50ESL74M 1974
50ES75B, 50ESL75B 1975
50R79C, 50RL79C 1979
55E76E, 55EL76E 1976
55E77D, 55EL77D 1977
55E78S, 55EL78S 1978
55E79C, 55EL79C 1979
55ES69A, 55ES69C, 55ESL69A, 55ESL69C 1969
60ES70B, 60ES70D, 60ESL70B, 60ESL70D 1970
60ES71C, 60ES71E, 60ESL71C, 60ESL71E 1971
65ES72S, 65ESL72S 1972
65ES73R, 65ESL73R 1973
70EL76D 1976
70EL77S 1977
70EL78C 1978
70EL79R 1979
70ES74M, 70ESL74M, 70ESLR74M 1974
70ES75B, 70ES75E, 70ESL75B, 70ESL75E 1975
75ELR76D, 75ER76D 1976
75ELR77S, 75ER77S 1977
75ELR78C, 75ER78C 1978
75ELR79R, 75ER79R 1979
75ESLR75B, 75ESR75B 1975
85ESL69E, 85ESL69M, 85ESL69S 1969
85ESL70B, 85ESL70D 1970
85ESL71A, 85ESL71H 1971
85ESL72R 1972
BJ50DTLEDC, J50DTLEDC, J50ELED 1996
BJ50DTLEUR, J50DTLEUR, J50ELEUR 1997
BJ60ELEDR, BJ60TLEDR, J60ELEDR, J60TLEDR, SJ60TLEDR 1996
BJ60ELEUA, BJ60TLEUA, J60ELEUA, J60TLEUA 1997
BJ60TLECM, J60TLECM 1998
BJ70ELECB, BJ70TLECB, J70TLECB 1998
BJ70ELEDA, BJ70TLEDA, HJ70TXEDA, J70TLEDA, SJ70TLEDA 1996
BJ70ELEUM, BJ70TLEUM, HJ70TXEUM, J70TLEUM 1997
BJ70PLEEE, J70PLEEE 1999
BJ70PLSIS, J70PLSIS, J70VLSIS, RJ70PLSIS 2001
BJ70PLSSD, J70PLSSD, RJ70PLSSD 2000
J35AELCDE, J35ARLCDE 1986
J35AELCUD, J35ARLCUD 1987
J40AELCCS, J40ARLCCS, J40ATLCCS, J40ECCS, J40ELCCS, J40RCCS, J40RLCCS, J40TECCS, J40TELCCS, J40TLCCS, J40TTLCCS 1988
J40ECDE, J40ELCDE, J40RCDE, J40RLCDE, J40TECDE, J40TELCDE, J40TLCDE 1986
J40ECOB, J40ELCOB, J40RCOB, J40RLCOB, J40TECOB, J40TELCOB 1985
J40ECRM, J40ELCRM, J40RCRM, J40RLCRM, J40TECRM, J40TELCRM 1984
J40ECUD, J40ELCUD, J40RCUD, J40RLCUD, J40TECUD, J40TLCUD 1987
J40JPLEEC 1999
J40JPLSIA, J40JVLSIA 2001
J40JPLSSR 2000
J45RCE, J45RCLE, J45WMLE 1989
J45RCEIA, J45RCLEIA, J45WMLEIA 1991
J45RCENM, J45RCLENM, J45WMLENM 1992
J45RCESR, J45RCLESR, J45WMLESR 1990
J48ESLCCC, VJ48ESLCCC 1988
J48ESLCCC, VJ48ESLCCC 1988
J48ESLCUS 1987
J48ESLCUS 1987
J50BECCS, J50BELCCS, J50TELCCS, J50TLCCS 1988
J50BECDE, J50BELCDE, J50TELCDE, J50TLCDE 1986
J50BECIC, J50BELCIC 1981
J50BECNR, J50BELCNR 1982
J50BECOB, J50BELCOB, J50TELCOB, J50TLCOB 1985
J50BECRM, J50BELCRM, J50TELCRM, J50TLCRM 1984
J50BECTA, J50BELCTA, J50TELCTA 1983
J50BECUD, J50BELCUD, J50TELCUD, J50TLCUD 1987
J50DTLECA 1998
J50DTLEOS, J50ELEOS 1995
J50ECSR, J50ELCSR 1980
J55RCIM, J55RLCIM 1981
J55RLCSA 1980
J55RSLN, J55RSLN-2, J55RSN, J55RSN-2, J55RSYN, J55RSYN-2 1983
J55RWLE 1989
J55RWLEIA 1991
J55RWLENM 1992
J55RWLESR 1990
J60ECIA, J60ECIH, J60ELCIA, J60ELCIH, J60TLCIA, J60TLCIH 1981
J60ECNM, J60ELCNM, J60TLCNM 1982
J60ECSR, J60ELCSR 1980
J60ECTB, J60ELCTB, J60TLCTB 1983
J60ELCCR, J60TLCCR, J60TTLCCR 1988
J60ELCDS, J60TLCDS 1986
J60ELCEA, J60TLCEA, J60TTLCEA, TJ60TLCEA, TJ60TLESF 1989
J60ELCOD, J60TLCOD 1985
J60ELCRE, J60TLCRE 1984
J60ELCUC, J60TLCUC 1987
J60ELEIB, J60TLEIB, TJ60TLEIB, VJ60ELEIB, VJ60TLEIB 1991
J60ELENE, J60TLENE, TJ60TLENE, VJ60ELENE, VJ60TLENE 1992
J60ELEOC, J60TLEOC 1995
J60ELERS, J60ELERV, J60TLERS, J60TLERV 1994
J60ELESM, J60TLESM, J60TTLESM, TJ60TLESF, TJ60TLESM, VJ60ELESM, VJ60TLESM 1990
J60ELETD, J60TLETD, TJ60TLETD, VJ60ELETD 1993
J60PLEEB 1999
J60PLSID, J60VLSID 2001
J60PLSSE 2000
J65WELEES 1999
J65WELSIR 2001
J65WELSSC 2000
J65WMLCDR 1986
J65WMLCOC, J65WTLCOC 1985
J65WMLCUA 1987
J65WMLEIB 1991
J65WMLENE 1992
J65WMLEOC 1995
J65WMLERS 1994
J65WMLESM 1990
J65WMLETD 1993
J65WMLZ 1989
Information:
Disconnect the leads between the regulator and generator when testing insulation resistance of generator windings with a megger.Testing of components may be done with either an ohmmeter or an 8S4627 Continuity Circuit Tester.Rectifier Test
Connect the ohmmeter or circuit tester across the rectifier. Observe the ohmmeter reading or whether or not the circuit tester bulb lights.Reverse the leads and again observe the ohmmeter reading or whether the circuit tester bulb lights.A good rectifier will have high resistance in one direction and low resistance in the opposite direction. If the circuit tester is used, the bulb should light in the direction where resistance is low, and should not light in direction of high resistance. If a low resistance is observed, or if the bulb glows, in both of the above tests, the rectifier is probably shorted and should be replaced. High resistance in both tests indicates an open rectifier and replacement is necessary.
RECTIFIER TEST PROCEDURECapacitor Test
Capacitors are best checked on a capacitance bridge that measures their value and leakage. Capacitors that vary more than 10% of their rated value should be replaced.An approximate test of a capacitor may be made with an ohmmeter set on a high resistance scale. The meter will initially indicate a low resistance and then gradually increase until the capacitor is fully charged.Saturable Transformer Testing
Typical defects found in any type of transformer are open and shorted windings. Open windings are easily determined by disconnecting the transformer from the circuit and testing for continuity with an ohmmeter. Shorted windings or shorts between windings are more difficult to determine. A resistance check can be made and compared against those of a transformer known to be good. However, the best policy is to replace a transformer that is suspect.Power Transformer Test
Disconnect the secondary windings. Start the engine and increase RPM until rated voltage is measured across the primary.Measure the output voltage across the secondary. It may be necessary to exceed rated RPM about 10% in order to obtain rated voltage in the primary. Exercise extreme caution during this test.Since the resistance of the windings in most transformers is so low, it is often very difficult to locate a problem with an ohmmeter. If the transformer has overheated, the fault may be shorted turns. In this case, check the no-load alternating current in the primary. Disconnect the secondary from the load. There will be excessive current in the primary if there are shorted turns.Current Transformer Test
Current transformers have a fixed ratio of current between the primary and the secondary. This ratio is determined by the ratio of winding turns. The following test may be made to check for shorted turns: 1. Load the generator to produce primary current in the transformer.2. Measure the secondary current.
Do not open the secondary circuit of a current transformer when the circuit is energized.
The ratio of primary to secondary current is approximately the same as the ratio of secondary turns to primary turns. If secondary current is considerably less than it should be, shorted turns are indicated.Rheostats And Resistors
Check the resistance values of these components with an ohmmeter. Rheostats and adjustable resistors should be checked over their entire range. Care should be taken to avoid damage to the fine wire when setting adjustment bands on adjustable resistors. The adjustment band should be loosened until it slides freely on the resistor tube.Silicon Transistor Test
Silicon transistors can be tested for opens or shorts using the 8S4627 Continuity Circuit Tester. Remove the transistor from the circuit to prevent other components from affecting the indicators. The light indications shown in the chart are those which should be observed if the transistor is not shorted or open. Testing Rotating Rectifiers (Diodes)
If a failure of one of the rotating rectifiers (diodes) is suspected, remove the generator cover and test the rectifier (diode) with an ohmmeter. The 8S4627 Continuity Circuit Tester may be used in lieu of an ohmmeter.1. Remove the nut and washer holding the diode in the heat sink. Remove the lead from the diode and remove the diode from the heat sink.2. Connect the ohmmeter (or tester) leads across the rectifier in one direction. Note the meter reading (or whether the light glows or not). The meter should indicate a low resistance in one direction and a high resistance in the opposite direction. (Light will burn in one direction and not in the other.)3. If a low resistance indication is obtained in both directions the diode is shorted. A high resistance in both directions indicates an open. In either case, the rectifier (diode) must be replaced.
ROTATING RECTIFIER (DIODE) LOCATION
1-Rectifiers (Diodes).Surge Protector Test
Use the same procedure for testing the surge protectors as outlined for the rotating rectifiers. However, a very high value of resistance should be indicated in both directions. The test lamp should not light in either direction. A low value of resistance (or a glowing lamp) indicates a short. Replace the surge suppressor in this event.
SURGE SUPPRESSOR LOCATION
Connect the ohmmeter or circuit tester across the rectifier. Observe the ohmmeter reading or whether or not the circuit tester bulb lights.Reverse the leads and again observe the ohmmeter reading or whether the circuit tester bulb lights.A good rectifier will have high resistance in one direction and low resistance in the opposite direction. If the circuit tester is used, the bulb should light in the direction where resistance is low, and should not light in direction of high resistance. If a low resistance is observed, or if the bulb glows, in both of the above tests, the rectifier is probably shorted and should be replaced. High resistance in both tests indicates an open rectifier and replacement is necessary.
RECTIFIER TEST PROCEDURECapacitor Test
Capacitors are best checked on a capacitance bridge that measures their value and leakage. Capacitors that vary more than 10% of their rated value should be replaced.An approximate test of a capacitor may be made with an ohmmeter set on a high resistance scale. The meter will initially indicate a low resistance and then gradually increase until the capacitor is fully charged.Saturable Transformer Testing
Typical defects found in any type of transformer are open and shorted windings. Open windings are easily determined by disconnecting the transformer from the circuit and testing for continuity with an ohmmeter. Shorted windings or shorts between windings are more difficult to determine. A resistance check can be made and compared against those of a transformer known to be good. However, the best policy is to replace a transformer that is suspect.Power Transformer Test
Disconnect the secondary windings. Start the engine and increase RPM until rated voltage is measured across the primary.Measure the output voltage across the secondary. It may be necessary to exceed rated RPM about 10% in order to obtain rated voltage in the primary. Exercise extreme caution during this test.Since the resistance of the windings in most transformers is so low, it is often very difficult to locate a problem with an ohmmeter. If the transformer has overheated, the fault may be shorted turns. In this case, check the no-load alternating current in the primary. Disconnect the secondary from the load. There will be excessive current in the primary if there are shorted turns.Current Transformer Test
Current transformers have a fixed ratio of current between the primary and the secondary. This ratio is determined by the ratio of winding turns. The following test may be made to check for shorted turns: 1. Load the generator to produce primary current in the transformer.2. Measure the secondary current.
Do not open the secondary circuit of a current transformer when the circuit is energized.
The ratio of primary to secondary current is approximately the same as the ratio of secondary turns to primary turns. If secondary current is considerably less than it should be, shorted turns are indicated.Rheostats And Resistors
Check the resistance values of these components with an ohmmeter. Rheostats and adjustable resistors should be checked over their entire range. Care should be taken to avoid damage to the fine wire when setting adjustment bands on adjustable resistors. The adjustment band should be loosened until it slides freely on the resistor tube.Silicon Transistor Test
Silicon transistors can be tested for opens or shorts using the 8S4627 Continuity Circuit Tester. Remove the transistor from the circuit to prevent other components from affecting the indicators. The light indications shown in the chart are those which should be observed if the transistor is not shorted or open. Testing Rotating Rectifiers (Diodes)
If a failure of one of the rotating rectifiers (diodes) is suspected, remove the generator cover and test the rectifier (diode) with an ohmmeter. The 8S4627 Continuity Circuit Tester may be used in lieu of an ohmmeter.1. Remove the nut and washer holding the diode in the heat sink. Remove the lead from the diode and remove the diode from the heat sink.2. Connect the ohmmeter (or tester) leads across the rectifier in one direction. Note the meter reading (or whether the light glows or not). The meter should indicate a low resistance in one direction and a high resistance in the opposite direction. (Light will burn in one direction and not in the other.)3. If a low resistance indication is obtained in both directions the diode is shorted. A high resistance in both directions indicates an open. In either case, the rectifier (diode) must be replaced.
ROTATING RECTIFIER (DIODE) LOCATION
1-Rectifiers (Diodes).Surge Protector Test
Use the same procedure for testing the surge protectors as outlined for the rotating rectifiers. However, a very high value of resistance should be indicated in both directions. The test lamp should not light in either direction. A low value of resistance (or a glowing lamp) indicates a short. Replace the surge suppressor in this event.
SURGE SUPPRESSOR LOCATION
Parts bushing JOHNSON:
0312708
0312708 BUSHING,Starter
100ML79S, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 4R69B, 4R70E, 4R71D, 4R72S, 4R73C, 4R74R, 4R75A, 4R76M, 4R77B, 4R78E, 50ES72C, 50ES73R, 50ES74M, 50ES75B, 50R79C, 55E76E, 55E77D, 55E78S, 55E79C, 65ES73R, 70EL
0308532
0308532 BUSHING
100ESL71A, 100ESL72R, 100ML79S, 115EL77S, 115ESL69E, 115ESL70D, 115ESL73M, 115ESL74B, 115ESL75E, 115ETZ78C, 115ML79R, 115TXL77S, 125ESL71C, 125ESL72R, 135ESL73M, 135ESL74B, 135ESL75E, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL7
0304765
0304765 BUSHING,Shift rod
10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 20R69B, 20R70C, 20R71S, 20R72R, 20R73A, 25E72R, 25E73A, 25E74M, 25E75B, 25E76E, 25E77S, 25E78C, 25E79R, 25R69B, 25R70C, 25R71S, 33E69A, 33E69A, 33E70M, 3
0315094
0315094 BUSHING
100ESL71A, 115ESL69E, 115ESL70D, 125ESL71C, 150TL78S, 175TL77S, 175TL78C, 200TL76S, 200TL77C, 200TL78R, 235TL78R, 85ESL69E, 85ESL70B, 85ESL71A, CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, J120TLAEM, J120TLAIE, J120TLASB, J120TLCCA, J120TLCDC, J12
0315101
0315101 BUSHING
100ESL71A, 100ML79S, 115ESL69E, 115ESL70D, 115ESL73M, 115ETZ78C, 115ML79R, 125ESL71C, 135ESL73M, 140ML78C, 140ML79R, 25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, 50ES71S, 50ES72C, 85ESL69E, 85ESL70B, 85ESL71A, 85ESL73M, 85ETLR78C, 85ML79R,
0318951
0318951 BUSHING,Shift lever to motor cover,outer
10E74G, 10E75C, 10E76G, 10E77A, 10E78M, 10EL79B, 15E74G, 15E75C, 15E76A, 15E77M, 15E78B, 15E79E, 70EL79R, 75ELR79R, BJ50DTLEDC, BJ50DTLEUR, BJ60ELEDR, BJ60ELEUA, BJ60TLECM, BJ70ELECB, BJ70ELEDA, BJ70ELEUM, BJ70PLEEE, BJ70PLSIS, BJ70PLSSD, J10ECCD, J1
0319787
0319787 BUSHING, Swivel bracket
115EL77S, 115ESL74B, 115ESL75E, 135ESL74B, 135ESL75E, 25E77S, 25E78C, 25E79R, 35E76G, 35E77C, 35E78R, 35E79A, 70EL76D, 70EL77S, 70ES74M, 70ES75B, 75ELR76D, 75ELR77S, 75ESLR75B, 85EL76D, 85EL77S, 85ESL74B, 85ESL75E, BJ10EEDD, BJ10FAEDC, BJ10FAEUR, BJ1
0323764
0323764 BUSHING,Cam,hub cover
100ML79S, 115ML79R, 140ML79R, 150TL79C, 175TL79R, 200TL79A, 235TL70A, 50R79C, 55E79C, 70EL79R, 75ELR79R, 85ML79R, CJ275TLCDC, CJ275TLCOS, CJ300TLCDC, CJ300TLCOS, D100WTLM, HJ55WMLM, HJ55WMLZ, J100MLCSC, J100STLCCA, J100STLCEM, J100STLESB, J100WMLCDR,