0581531 CABLE JOHNSON
100ML79S, 115ETZ78C, 115ML79R, 115TXL77S, 140ML77S, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL77S, 175TL78C, 175TL79R, 200TL76S, 200TL77C, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, 85TXLR77S, J100MLCSC, J115MLCIH, J115MLCSA, J140
CABLE
Price: query
Rating:
You can buy parts:
As an associate, we earn commssions on qualifying purchases through the links below
Compatible models:
100ML79S
115ETZ78C
115ML79R
115TXL77S
140ML77S
140ML78C
140ML79R
150TL78S
150TL79C
175TL77S
175TL78C
175TL79R
200TL76S
200TL77C
200TL78R
200TL79A
235TL70A
235TL78R
85ETLR78C
85ML79R
85TXLR77S
J100MLCSC
J115MLCIH
J115MLCSA
J140MLCIH
J140MLCSA
J150TLCIA
J150TLCSF
J175TLCIH
J175TLCSA
J200TLCIH
J200TLCSF
J235TLCIB
J235TLCSM
J70ELCIH
J70ELCSA
J75ERCIH
J75ERCSA
J85MLCSA
J90MLCIH
JOHNSON
BRP JOHNSON entire parts catalog list:
- POWER TILT AND TRIM » 0581531
115ML79R, 115TL79R, 115TXL79R 1979
115TXL77S 1977
140ML77S, 140TL77S, 140TXL77S 1977
140ML78C, 140TL78C, 140TX78C 1978
140ML79R, 140TL79R, 140TXL79R 1979
150TL78S, 150TXL78S 1978
150TL79C, 150TXL79C 1979
175TL77S, 175TXL77S 1977
175TL78C, 175TX78C 1978
175TL79R, 175TXL79R 1979
200TL76S, 200TXL76S 1976
200TL77C, 200TXL77C 1977
200TL78R, 200TX78R 1978
200TL79A, 200TXL79A 1979
235TL70A, 235TXL79A 1979
235TL78R, 235TX78R 1978
85ETLR78C, 85ML78C, 85TXLR78C 1978
85ML79R, 85TL79R, 85TXL79R 1979
85TXLR77S 1977
J100MLCSC, J100TRLCSC, J100TRXCSC 1980
J115MLCIH, J115MLCIM, J115TLCIH, J115TLCIM, J115TXCIH, J115TXCIM 1981
J115MLCSA, J115TLCSA, J115TXCSA 1980
J140MLCIH, J140MLCIM, J140TLCIH, J140TLCIM, J140TXCIH, J140TXCIM 1981
J140MLCSA, J140TLCSA, J140TXCSA 1980
J150TLCIA, J150TLCIH, J150TXCIA, J150TXCIH 1981
J150TLCSF, J150TLCSR, J150TXCSF, J150TXCSR 1980
J175TLCIH, J175TLCIM, J175TXCIH, J175TXCIM 1981
J175TLCSA, J175TLCSF, J175TXCSA, J175TXCSF 1980
J200TLCIH, J200TXCIB, J200TXCIH 1981
J200TLCSF, J200TLCSM, J200TXCSF, J200TXCSM 1980
J235TLCIB, J235TLCIH, J235TXCIB, J235TXCIH 1981
J235TLCSM, J235TXCSM 1980
J70ELCIH, J70ELCIM, J70TLCIM 1981
J70ELCSA 1980
J75ERCIH, J75ERCIM, J75ERLCIH, J75ERLCIM, J75TELCIM, J75TRLCIH 1981
J75ERCSA, J75ERLCSA, J75TRLCSA 1980
J85MLCSA, J85TLCSA, J85TXCSA 1980
J90MLCIH, J90MLCIM, J90TLCIH, J90TLCIM, J90TXCIH, J90TXCIM 1981
Information:
Table 1
J1939 Code and Description CDL Code and Description Comments
430-5
Engine Starter Motor Solenoid : Current Below Normal 444-5
Starter Motor Relay : Current Below Normal This code indicates that there is a problem with the engine starter motor solenoid and/or the electrical circuit on the Electronic Control Module (ECM).
430-6
Engine Starter Motor Solenoid : Current Above Normal 444-6
Starter Motor Relay : Current Above Normal This code indicates that there is a problem with the engine starter motor solenoid and/or the electrical circuit on the ECM.
677-5
Engine Starter Motor Relay : Current Below Normal 444-5
Starter Motor Relay : Current Below Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
677-6
Engine Starter Motor Relay : Current Above Normal 444-6
Starter Motor Relay : Current Above Normal This code indicates that there is a problem with the engine starter motor relay and/or the electrical circuit on the ECM.
4210-5
Engine Pre-lube Drive : Current Below Normal 338-5
Engine Pre-Lube Pump Relay : Current Below Normal This code indicates that there is a problem with the prelubrication solenoid and/or the electrical circuit on the ECM.
4210-6
Engine Pre-lube Drive : Current Above Normal 338-6
Engine Pre-Lube Pump Relay : Current Above Normal This code indicates that there is a problem with the prelubrication solenoid and/or the electrical circuit on the ECM. Electrical Checkouts on the Cat® Electronic Technician (ET)
Table 2
Component Electrical Checkout
Engine Starter Solenoid Attempt to start the engine. Once the ECM attempts to energize the solenoid, the code will become active. Refer to the application-specific schematic for the "Engine Starter Motor Solenoid" wiring circuit.
Engine Starter Motor Relay Attempt to start the engine. Once the ECM attempts to energize the solenoid, the code will become active. Refer to the application-specific schematic for the "Engine Starter Motor Relay" wiring circuit.
Prelubrication System Relay Prelubrication Relay Override
Illustration 1 g03731016
Primary and Secondary ECMs
Table 3
Troubleshooting Test Steps Values Results
1. Check for Codes
A. Connect Cat® Electronic Technician (ET) to the service tool connector.
B. Determine if a code is active or logged.
Codes
Result: A -5 code is active or logged.
Proceed to Test Step 2.
Result: A -6 code is active or logged.
Proceed to Test Step 3.
2. Check the Wiring for an Open Circuit
A. Verify that the harness connector is free of debris, free of corrosion, and securely connected.
B. Disconnect the solenoid from the harness.
C. Connect a jumper wire between the terminals of the harness connector for the affected coil. The coil is replaced with a short circuit.
Create a Short
Result: A -5 code became active during the electrical checkout. The Electronic Control Module (ECM) did not detect the jumper wire. There is an open circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -6 code is activated during the electrical checkout. The ECM detected the jumper wire. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
3. Check the Wiring for a Short Circuit
A. Disconnect the solenoid from the harness.
Create an Open
Result: A -6 code became active during the electrical checkout. The ECM did not detect the open circuit. There is a short circuit in the wiring between the coil and the ECM connector. There may be a problem with a connector.
Repair: Repair or replace the connectors or the wiring.
Verify that the repair eliminated the problem.
Result: A -5 code is activated during the electrical checkout. The ECM detected the open circuit. There is a problem with the solenoid.
Repair: Replace the solenoid.
Verify that the repair eliminated the problem.
If the procedure did not correct the issue, contact your Cat dealer Technical Communicator (TC). For further assistance, your TC can confer with the Dealer Solutions Network (DSN).
Parts cable JOHNSON:
0581532
0581874
0581874 CABLE ASSY., Tilt and trim
100ML79S, 115ETZ78C, 115ML79R, 140ML78C, 140ML79R, 150TL78S, 150TL79C, 175TL78C, 175TL79R, 200TL78R, 200TL79A, 235TL70A, 235TL78R, 85ETLR78C, 85ML79R, J100MLCSC, J115MLCIH, J115MLCSA, J140MLCIH, J140MLCSA, J150TLCIA, J150TLCSF, J175TLCIH, J175TLCSA,
0582028
0582028 CABLE ASSY.,Tilt & trim motor
J100MLCSC, J115MLCIH, J115MLCSA, J140MLCIH, J140MLCSA, J150TLCIA, J150TLCSF, J175TLCIH, J175TLCSA, J200TLCIH, J200TLCSF, J235TLCIB, J235TLCSM, J70ELCIH, J70ELCSA, J75ERCIH, J75ERCSA, J85MLCSA, J90MLCIH
0581960
0581960 CABLE ASSY.,Sending unit
J100MLCSC, J115MLCIH, J115MLCNB, J115MLCSA, J115MLCTE, J140MLCIH, J140MLCNB, J140MLCSA, J140MLCTE, J150STLCTE, J150TLCIA, J150TLCNM, J150TLCSF, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCSA, J175TLCTD, J200TLCIH, J200TLCNE, J200TLCSF, J200TLCTD, J235STL
0582182
0582182 CABLE ASSY., Battery
J115MLCIH, J115MLCNB, J115MLCTE, J140MLCIH, J140MLCNB, J140MLCTE, J150STLCTE, J150TLCIA, J150TLCNM, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCTD, J200TLCIH, J200TLCNE, J200TLCTD, J235STLCTS, J235TLCIB, J235TLCNE, J235TLCTD, J70ELCIH, J70ELCNB, J70ELCTE
0582187
0582187 CABLE ASSY., TRIM SWITCH & guage
J115MLCIH, J115MLCNB, J115MLCTE, J140MLCIH, J140MLCNB, J140MLCTE, J150STLCTE, J150TLCIA, J150TLCNM, J150TLCTB, J175TLCIH, J175TLCNB, J175TLCTD, J200TLCIH, J200TLCNE, J200TLCTD, J235STLCTS, J235TLCIB, J235TLCNE, J235TLCTD, J70ELCIH, J70ELCNB, J70ELCTE
0582188
0582188 CABLE ASSY. TNT MOTOR