0585017 CABLE, Trim motor & control JOHNSON
BJ50DTLEDC, BJ50DTLEUR, BJ60ELEDR, BJ60ELEUA, BJ60TLECM, BJ70ELECB, BJ70ELEDA, BJ70ELEUM, BJ70PLEEE, BJ70PLSIS, BJ70PLSSD, J40JPLEEC, J40JPLSIA, J40JPLSSR, J50DTLECA, J50TTLECA, J50TTLEDC, J50TTLEUR, J60PLEEB, J60PLSID, J60PLSSE, J60TTLECM, J60TTLEDR
CABLE
Price: query
Rating:
Compatible models:
BRP JOHNSON entire parts catalog list:
- POWER TRIM-TILT ELECTRICAL » 0585017
BJ60ELEDR, BJ60TLEDR, J60ELEDR, J60TLEDR, SJ60TLEDR 1996
BJ60ELEUA, BJ60TLEUA, J60ELEUA, J60TLEUA 1997
BJ60TLECM, J60TLECM 1998
BJ70ELECB, BJ70TLECB, J70TLECB 1998
BJ70ELEDA, BJ70TLEDA, HJ70TXEDA, J70TLEDA, SJ70TLEDA 1996
BJ70ELEUM, BJ70TLEUM, HJ70TXEUM, J70TLEUM 1997
BJ70PLEEE, J70PLEEE 1999
BJ70PLSIS, J70PLSIS, J70VLSIS, RJ70PLSIS 2001
BJ70PLSSD, J70PLSSD, RJ70PLSSD 2000
J40JPLEEC 1999
J40JPLSIA, J40JVLSIA 2001
J40JPLSSR 2000
J50DTLECA 1998
J50TTLECA 1998
J50TTLEDC 1996
J50TTLEUR 1997
J60PLEEB 1999
J60PLSID, J60VLSID 2001
J60PLSSE 2000
J60TTLECM 1998
J60TTLEDR 1996
J60TTLEUA 1997
Information:
Table 1
Diagnostic Codes Table    
Description    Conditions which Generate this Code    System Response    
267-2 Remote Shutdown Input erratic, intermittent, or incorrect     Both of the switch contacts of the ground level shutdown switch are in the same state.     If both of the switch contacts from the ground level shutdown switch change to the same state and the engine is running, the engine will continue to run. The code is logged.    
Illustration 1 g01345181
SchematicTest Step 1. Inspect the Electrical Connectors and the Wiring
Remove electrical power from the ECM.
Illustration 2 g01258956
(1) J1/P1
Thoroughly inspect the J1/P1 ECM connectors and the connector for the engine shutdown switch. Also inspect each of the machine connectors that are in the circuit. Refer to Troubleshooting, "Electrical Connectors - Inspect" for details.
Illustration 3 g01213917
Terminal locations at the P1 ECM connector (P1-5) Digital sensor return (P1-23) Engine shutdown switch (N/C) (P1-40) Engine shutdown switch (N/O)
Illustration 4 g01159881
Harness connector for the engine shutdown switch (Terminal A) Engine shutdown switch (N/C) (Terminal B) Digital return (Terminal C) Engine shutdown switch (N/O)
Perform a 45 N (10 lb) pull test on each of the wires for the engine shutdown switch.
Check the torque of the allen head screw on the ECM connectors. Refer to Troubleshooting, "Electrical Connectors - Inspect" for the correct torque values.
Check the harness and the wiring for abrasion and for pinch points from the switch back to the ECM.Expected Result:All of the connectors, pins and sockets are completely coupled and/or inserted and the harness and wiring are free of corrosion, of abrasion and of pinch points.Results:
OK - The harness and the connectors appear to be OK. Proceed to Test Step 2.
Not OK - The connectors and/or wiring need repair.Repair: Repair the wiring and/or the connectors. Replace parts, if necessary. Ensure that all of the seals are properly in place and ensure that the connectors are completely coupled. Verify that the repair eliminates the problem.STOPTest Step 2. Check the Status of the Shutdown Switch on Cat ET
Connect Cat ET to the service tool connector.
Restore electrical power to the ECM.
Monitor the status screen on Cat ET while you operate the shutdown switch. Observe the status for the shutdown switch.Note: Wait at least 30 seconds for the status of the switch to change.Expected Result:The status of the shutdown switch reads "ON" with the shutdown switch in the STOP position. The status of the shutdown switch reads "OFF" when the shutdown switch is in the RUN position.Results:
OK - The status of the shutdown switch reads "ON" with the shutdown switch in the STOP position. The status of the shutdown switch reads "OFF" when the shutdown switch is in the RUN position. The shutdown switch is operating normally.Repair: The circuit for the shutdown switch appears to be operating correctly. There may be an intermittent problem in the harness or in a connector. If an intermittent problem is suspected, refer to Troubleshooting, "Inspecting Electrical Connectors".STOP
Not OK - The status of the switch does not read "ON" with the shutdown switch in the STOP position. The status of the shutdown switch does not read "OFF" when the shutdown switch is in the RUN position. There is a problem with the circuit for the shutdown switch. There may be a problem with the ECM. Proceed to Test Step 3.Test Step 3. Short the Terminals at the Harness Connector for the Shutdown Switch
Remove electrical power from the ECM.
Fabricate a jumper wire that is long enough to short circuit two terminals at the harness connector for the shutdown switch. Crimp connector pins to each end of the jumper wire.
Disconnect the harness connector for the shutdown switch.
Check the status of the shutdown switch while the circuit is shorted to the RUN position.
Install the jumper wire between terminals B (digital return) and A (engine shutdown switch (N/C)) at the harness connector for the switch.
Restore electrical power to the ECM.
Observe the status of the shutdown switch on Cat ET.Note: Wait at least 30 seconds for the status of the switch to change.The correct status for the shutdown switch is "OFF".
Remove electrical power from the ECM.
Check the status of the shutdown switch while the circuit is shorted to the STOP position.
Install the jumper wire between terminals C (engine shutdown switch (N/O)) and B (digital return) at the harness connector for the switch.
Restore electrical power to the ECM.
Observe the status of the shutdown switch on Cat ET.Note: Wait at least 30 seconds for the status of the switch to change.The correct status for the shutdown switch is "ON".
Remove electrical power from the ECM.
Remove the jumper wire from the harness connector.Expected Result:The switch status on Cat ET agrees with the test results that are stated above.Results:
OK - The switch status on Cat ET agrees with the test results.Repair: There is a problem with the shutdown switch. Replace the shutdown switch. Verify that the new shutdown switch solves the problem.STOP
Not OK - The switch status on Cat ET does not agree with the test results that are stated above. The problem is in the harness between the ECM and the harness connector for the switch. There may be a problem with the ECM. Proceed to Test Step 4.Test Step 4. Short the Terminals for the Shutdown Switch at the ECM
Disconnect the J1/P1 ECM connectors.
Fabricate three jumper wires that are long enough to short circuit terminals at the P1 ECM connector. Crimp connector sockets to one end of each of the jumper wires.
Remove the wires from terminal locations P1-5, P1-23, and P1-40 at the ECM connector. Install a jumper wire into each of these terminal locations.
Check the status of the shutdown switch while the circuit is shorted to the RUN position.
Short circuit the ends of the jumper wires that are
Parts cable JOHNSON:
0583207
0583207 CABLE ASSY., Switch & gauge
BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, CJ275TLCDC, CJ300TLCDC, J115ELEOC, J125WTPLE, J130CXAOR, J150CXCCA, J150CXCEM, J150CXESB, J150ELEOM, J150TLCDC, J150TLCUR, J150WTLEOR, J155WTLCDR, J155WTLCUA, J155WTLEIB, J155WTLENE, J155WTLESM, J155WTLZ, J175EXEOM,
0584177
0584177 CABLE, Trim motor & control
BJ50DTLEDC, BJ60ELEDR, BJ70ELEDA, J50DTLEOS, J60ELEIB, J60ELENE, J60ELEOC, J60ELERS, J60ELETD, J70ELEIE, J70ELEND, J70ELEOR, J70ELERC, J70ELETS
0175202
0175202 CABLE ASSEMBLY
BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ50BEEDS, BJ50EEER, BJ50ELSIF, BJ50ELSSA, BJ50ESECC, BJ50RLEUC, J115JKLEOC, J115JKLERS, J40EEOD, J40EERE, J40EETB, J50BEEOD, J50BEERE, J50BEETB, J50TTLECA, J50TTLEDC, J50TTLEOS, J50TTLEUR
0176418
0176418 CABLE ASSY.
BJ40EECR, BJ40EEDS, BJ40EEEA, BJ40EEUC, BJ40ELSIF, BJ40ELSSM, BJ50BEEDS, BJ50EEER, BJ50ELSIF, BJ50ELSSA, BJ50ESECC, BJ50RLEUC, J50TTLECA, J50TTLEDC, J50TTLEUR, J60TTLECM, J60TTLEDR, J60TTLEUA